Description
1. Introduction
The polyester suture Premisut Prime in ½ circle configuration, cylindrical body and conical point (taperpoint) of 20 mm is the reference solution for surgical departments seeking a high-performance non-absorbable thread with smooth handling and predictable tissue behaviour. Presented in USP 2/0 gauge and multipack presentation of 10 x 75 cm with 5 green and 5 white threads, it allows standardisation in the surgical block for soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery. It is supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the operating theatre department.
2. Technical explanation
The thread is composed of fine polyethylene terephthalate (polyester) fibres braided into a compact multifilament structure and coated with silicone (polyester-polyethylene). This coating improves passage through tissue, facilitates knot advancement, prevents sawing or channelling effects and reduces tissue trauma, without compromising tensile strength. Being non-absorbable, it does not degrade through the body’s enzymatic action: it maintains its tensile strength over a prolonged period, supporting the wound for more than three months while gradual encapsulation by fibrous connective tissue occurs.
The ½ circle needle allows suturing with controlled rotational movements and its conical point (taperpoint) passes through tissue by separating fibres without cutting them, with minimal tissue aggression. The double needle configuration (2xHR20) allows continuous sutures with two half-arcs without repositioning the needle in the needle holder, optimising surgical time. The dual 5+5 multipack (D&C Green No. 6 and undyed white) facilitates protocol standardisation in departments that use both colours.
3. Technical Specifications
3.1. General characteristics
| Characteristic | Specification |
|---|---|
| Brand / line | Premisut Prime (PREMISTER PRIME series) |
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET) |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic multifilament, coated, non-channelling |
| Gauge | USP 2/0 (metric size EP 3) |
| Thread length | 75 cm per thread; multipack 10 x 75 cm (5 green + 5 white) |
| Needle shape | 1/2 circle |
| Tip type | Cylindrical body with conical point (taperpoint), atraumatic |
| Needle configuration and size | Double needle 2xHR20, 20 mm |
| Number of needles | 2 (double needle) |
| Thread colour | Green (D&C Green No. 6) and white (undyed): 5 + 5 |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO), sterile, single-use, not re-sterilisable |
| Commercial presentation | Box of 12 units |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Factory reference | P882HR2020.10-2 (Premisut Prime line) |
| Reference Cahnos (SKU) | AMP882HR2020.10-2 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2/0 | 3 | 0.35 – 0.399 mm (USP/EP standard) |
4. Equivalences and Cross-References
Non-absorbable braided polyester suture is a well-established category in the market. The reference AMP882HR2020.10-2 corresponds to the official factory reference P882HR2020.10-2 of the Premisut Prime line (distributor’s own coding on the same technical configuration), thus constituting an exact reference equivalence. The localised variants with their equivalence level are indicated below:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (Cahnos) | Polyester 1/2 conical point 2xHR20, 2/0, 10×75 (5+5) | P882HR2020.10-2 / AMP882HR2020.10-2 | Exact reference equivalence (same product) | Official factory reference of the product itself; same configuration, dimensions and material. |
| Premisut Prime (Cahnos) | Polyester 1/2 conical point 2xHR20, 2/0, green, 75 cm | AMP852HR2020-2 | Family equivalence, not interchangeable 1:1 | Same needle 2xHR20, same gauge and length; single-colour presentation without dual multipack. Validate protocol preference. |
| Premisut Prime (Cahnos) | Polyester 1/2 conical point 2xHR20, 4/0, green, 75 cm | AMP852HR2040-2 | Family equivalence, not interchangeable 1:1 | Same needle and length; finer USP 4/0 gauge for very delicate tissues. |
| Premisut Prime (Cahnos) | Polyester 1/2 conical point 2xHR26, 2/0, green, 90 cm | AMP853HR2620-2 | Family equivalence, not interchangeable 1:1 | Same gauge and double needle configuration; 26 mm needle and 90 cm thread for larger fields. |
| Premisut Prime (Cahnos) | Polyester 1/2 trocar point 2xHRT17, 2/0, 10×75 (5+5), with pledget 6x3x1.5 mm | AMP882HRT1720.10PL6-2 | Family equivalence, not interchangeable 1:1 | Same 10×75 multipack and gauge; the point changes (trocar instead of conical) and incorporates a reinforcement pledget. |
| B. Braun (Aesculap) | PremiCron / Dagrofil (braided polyester) | Consult official catalogue for gauge and needle | Comparable by category, not interchangeable 1:1 | Same type of braided polyester thread; verify coating, 1/2 HR20 needle geometry and USP/EP gauge in the official technical data sheet before substituting. |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel / Mersilene (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; the coating differs (polybutylate versus silicone). Confirm actual point, radius and gauge. |
| Medtronic (Covidien) / Teleflex | Surgidac / Ti-Cron / Tevdek II (coated braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Same base material; Ti-Cron silicone-coated similar to Premisut. Confirm 2xHR20 needle and presentation in the official catalogue. |
Important note: there is no manufacturer-validated equivalence table cross-referencing the Premisut reference with other brands; the cross-references with B. Braun, Ethicon, Medtronic and Teleflex are functional category comparisons pending official confirmation. Consult the technical department of Cahnos before use in tendering or substitution of references.
5. Selection tips and variants of interest
- Dual 5+5 multipack: this 10 x 75 cm presentation unifies the consumption of green and white thread in a single pack, ideal for centralised purchasing and standardisation of operating theatre trolleys.
- Delicate tissues: the 20 mm conical point (taperpoint) offers atraumatic penetration by separating fibres without cutting them; if the protocol requires denser tissues, consider the trocar point (tapercut) from the same family with multipack (AMP882HRT1720.10PL6-2).
- Same needle, alternative gauge: with the 2xHR20 needle, USP 4/0 gauge (AMP852HR2040-2) is available for maximum fineness in ophthalmology and microsurgery.
- Larger surgical fields: the 2xHR26 needle variant with 90 cm thread (AMP853HR2620-2) provides greater reach while maintaining USP 2/0 gauge.
- Single-colour protocols: if your centre standardises green thread, the reference AMP852HR2020-2 maintains the same needle, gauge and length in individual presentation.
- Before changing brand: always check needle angle (1/2), size (20 mm), point type (conical/taperpoint), double needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: sterile product by ethylene oxide with a shelf life of 5 years, single-use and non-reesterilizable; respect the storage conditions (below 30 °C, away from humidity and direct sunlight) and the expiry date of the packaging.