Description
1. Product Presentation
The non-absorbable polyester suture Premisut Prime in a ½-circle configuration, cylindrical body and atraumatic conical point (Taperpoint) is the precision reference for surgical departments seeking a high-performance non-absorbable thread with exceptional handling and predictable tissue behaviour. Presented in USP 3/0 gauge with a double 17 mm needle and a dual presentation of 5 green threads and 5 white threads of 10×75 cm, it allows a unified approach in soft tissue approximation and ligation procedures, as well as in demanding specialties such as ophthalmology and neurosurgery.
Supplied in a box of 12 units sterilised by ethylene oxide, ready to use at the time of the procedure and designed for centralised purchasing by the surgical block, with a minimum order of 10 boxes.
2. Technical explanation
The thread is composed of fine fibres of polyethylene terephthalate (polyester, PET) braided into a compact multifilament structure and coated with silicone. This coating improves passage through tissue, facilitates knot advancement, prevents sawing or channelling effects and reduces tissue trauma, without compromising tensile strength.
Being a non-absorbable suture, it is not degraded by the body’s enzymatic action: it maintains its tensile strength over a prolonged period, providing wound support for more than three months while gradual encapsulation by fibrous connective tissue occurs. The ½-circle needle allows suturing in wide or restricted surgical fields with controlled rotational movements, while its conical point (Taperpoint) passes through tissue by separating fibres without cutting them, with minimal tissue trauma. The double-needle configuration (2xHR17) allows continuous sutures with two hemi-arcs without repositioning the needle in the needle holder, optimising surgical time. The green colour ensures optimal visibility over the surgical field and the white facilitates its use in protocols with minimal visual interference.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Thread material | Braided multifilament polyester (polyethylene terephthalate, PET), non-grooved surface |
| Coating | Silicone (polyester – polyethylene) |
| Suture type | Non-absorbable, synthetic coated multifilament |
| Gauge | USP 3/0 (metric measure EP 2) |
| Thread length | 10 × 75 cm (5 green and 5 white) |
| Needle shape | 1/2 circle (1/2 circular) |
| Tip type | Taperpoint conical (atraumatic) |
| Needle configuration and size | Double needle 2xHR17, 17 mm |
| Number of needles | 2 (double needle) |
| Thread colour | Green and white |
| Behaviour | No absorption; gradual encapsulation; tissue support exceeding 3 months |
| Tensile strength | High and permanent; exceeds USP and EP requirements |
| Sterilisation | Ethylene oxide (EO); sterile, single-use |
| Presentation | Box of 12 units |
| Minimum order | 10 boxes |
| Shelf life | 5 years |
| Regulatory standard | Compliant with Regulation (EU) 2017/745 (MDR); exceeds USP and EP requirements |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Factory reference | P882HR1730.10-2 |
| Reference Cahnos (SKU) | AMP882HR1730.10-2 |
3.2. Gauge equivalence (USP/EP table)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 3/0 | 2 | 0.20 – 0.249 mm (USP/EP standard) |
4. Equivalences and Cross-References
The factory reference for this product is P882HR1730.10-2; the distribution SKU Cahnos AMP882HR1730.10-2 corresponds to the same commercial unit. Within the same Premisut Prime family, only a change in thread colour maintains direct equivalent status; any variation in needle, gauge or length automatically downgrades to family equivalence. Cross-references with other brands are functional category comparisons and must always be verified against the manufacturer’s official technical data sheet or IFU before substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Premisut Prime (polyester line) | Polyester 1/2 conical point 2xHR17, 3/0, 5 green and 5 white, 10×75 cm | P882HR1730.10-2 / AMP882HR1730.10-2 | Reference analysed | Product covered by this data sheet; Prime quality with superior needle and finish. P882HR1730.10-2 is the factory code. |
| Premisut Prime (polyester line) | Polyester 1/2 conical point 2xHR17, 2/0, green, 90 cm | AMP853HR1720-2 (P853HR1720-2) | Family equivalence, not interchangeable 1:1 | Same 2xHR17 needle and conical point; differ in gauge (2/0), colour (green) and thread length (90 cm). |
| Premisut Prime (polyester line) | Polyester 1/2 conical point 2xHR20, 2/0, green and white, 10×75 cm | P882HR2020.10-2 (AMP852HR2020-2) | Family equivalence, not interchangeable 1:1 | Same dual presentation 10×75 and conical point; differs in needle size (20 mm) and gauge (2/0). |
| Premisut Prime (polyester line) | Polyester 1/2 conical point HR17, 3/0, green, 60 cm (single needle) | AMP856HR1730 (P856HR1730) | Family equivalence, not interchangeable 1:1 | Single needle versus double needle; configuration and thread length change (60 cm). |
| Ethicon (Johnson & Johnson MedTech) | Ethibond Excel / Mersilene (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Non-absorbable polyester multifilament with similar indications; the coating differs (polybutylate vs silicone). Confirm needle 2xHR17, 1/2 circle, conical point and USP/EP gauge. |
| B. Braun (Aesculap) | PremiCron / Dagrofil (braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Same type of braided polyester thread; verify coating, 1/2 HR17 needle geometry, conical point and USP/EP gauge in the official technical data sheet. |
| Medtronic (Covidien) | Ti-Cron / Surgidac (coated braided polyester) | Consult official catalogue | Comparable by category, not interchangeable 1:1 | Same base material; Ti-Cron with similar silicone coating. Confirm 2xHR17 configuration, conical point and presentation. |
Important note: there is no equivalence table validated by the manufacturer that cross-references this Premisut Prime reference with other brands; cross-references with Ethicon, B. Braun and Medtronic are functional category comparisons pending official confirmation. Consult the technical department of Cahnos before use in tenders or reference substitution.
5. Selection tips and variants of interest
- Delicate tissues and restricted fields: the 17 mm conical point (Taperpoint) offers atraumatic penetration by separating fibres without cutting them, ideal for ophthalmology, neurosurgery, soft tissue approximation and ligations.
- Greater needle travel: if the surgical field is wider, consider the variant with a 20 mm conical needle (AMP852HR2040-2 in 4/0 green 75 cm) or the dual 2xHR20 presentation (P882HR2020.10-2 in 2/0).
- Alternative gauges: within the same 2xHR17 needle, the 2/0 green 90 cm version (AMP853HR1720-2) is available and, in single HR17 needle, gauges 3/0 (AMP856HR1730) and 5/0 (AMP856HR1750).
- Dual presentation: this reference combines 5 green and 5 white threads, ideal for centres that standardise both colours in a single package; if the protocol requires a single colour, consult the single-colour variants of the family.
- Centralised purchasing: product available in a box of 12 units with a minimum order of 10 boxes; consult the conditions for hospital volumes with your Cahnos advisor.
- Before substituting brand: always check needle angle (1/2), size (17 mm), point type (conical/Taperpoint), double-needle configuration, USP/EP gauge, exact thread material and coating in the alternative manufacturer’s technical data sheet.
- Storage: product sterile by ethylene oxide with a 5-year shelf life, single-use and non-reesterilisable; respect storage conditions (below 30 °C, protected from humidity and direct sunlight) and the package expiry date.





Reviews
There are no reviews yet.