Description
Introduction
The non-absorbable polyester suture Premisut in USP 5/0 gauge with a ½ circle needle and conical point of 17 mm is a high-precision solution for the closure and approximation of soft tissues in specialised surgery. Designed to meet the demands of the operating theatre, it combines the safety of a long-lasting non-absorbable material with excellent handling: clean passage through tissue, stable knots and minimal tissue reaction. An essential reference for ophthalmology, neurosurgery and general surgery departments that value reliability and traceability in every unit.
Technical description
It is a synthetic, sterile and non-absorbable suture composed of high molecular weight polyester fibres (polyethylene terephthalate, PET), braided into a multifilament and uniformly coated with silicone to increase surface lubricity and facilitate sliding and knotting. As it does not degrade enzymatically or hydrolytically, it maintains the structural integrity of the wound for more than three months, gradually encapsulating in the fibrous tissue.
The needle-thread combination includes a ½ circle needle (curvature 1/2) with cylindrical body and conical Taperpoint point of 17 mm (HR17), ideal for delicate tissues where the aim is to minimise damage when passing through the tissue. It is presented sterile, ready for single use, and supplied in a box of 12 units.
Technical specifications
| Characteristic | Specification |
|---|---|
| Material | Silicone-coated braided multifilament polyester (polyester – polyethylene) |
| Structure | Braided multifilament (grooved surface) |
| Absorption | Non-absorbable, with gradual encapsulation and high tensile strength |
| Calibre (USP / metric) | 5/0 / 1 (EP) |
| Approximate diameter | 0.100 – 0.149 mm (synthetic non-absorbable suture, USP standard) |
| Thread colour | Green (white optional) |
| Thread length | 60 cm |
| Needle curvature | 1/2 circle |
| Needle body / tip | Cylindrical / conical (Taperpoint), atraumatic |
| Needle size | 17 mm (HR17) |
| Sterilisation | Ethylene oxide (EO); single-use, non-reesterilizable |
| Presentation | Box of 12 units (minimum order 30 boxes) |
| Factory reference | 856HR1750 |
| Indications | Soft tissue approximation, ligatures, ophthalmology and neurosurgery |
USP / metric gauge equivalence
| USP size | Metric (EP) | Approximate diameter |
|---|---|---|
| 5/0 | 1 | 0.100 – 0.149 mm |
| 4/0 | 1.5 | 0.150 – 0.199 mm |
| 3/0 | 2 | 0.200 – 0.249 mm |
Equivalences and cross-references
Within the Premisut family itself, the Prime quality variant (factory ref. P856HR1750, SKU in Cahnos AMP856HR1750) shares exactly the same dimensions (HR17 needle of 17 mm, size 5/0, green thread of 60 cm) and can be considered an exact reference equivalence in terms of format, differing only in the quality of polishing and handling of the thread. Likewise, the Premisut line offers the same HR17 format in size 3/0 (ref. 856HR1730).
There is no equivalence table validated by the manufacturer for this reference against other brands; the comparisons indicated below are functional category comparisons, not interchangeable 1:1, and require verification of needle dimensions, material, coating and length before use in tendering.
| Manufacturer / Brand | Family / Model | Reference code | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | PremiCron® (braided polyester coated with silicone) | C0026003 (5/0, HR17, green, 75 cm) | Comparable by category | Same structure and silicone coating and same HR17 needle nomenclature; 75 cm thread and round body needle. Verify needle and length |
| Ethicon (Johnson & Johnson) | ETHIBOND EXCEL® (braided polyester) | X550H (5/0, RB-1 17 mm, green, 75 cm, double needle) | Comparable by category | Same non-absorbable material and ½ circle needle of 17 mm with taper point; 75 cm thread, double needle and polybutylate coating. Not interchangeable 1:1 |
| Medtronic (Covidien) | Ti-Cron™ / Surgidac™ (braided polyester coated with silicone) | Consult catalogue for size 5/0 and needle | Comparable by category | Same type of material and silicone coating; indicated for cardiovascular, ophthalmic and neural tissue. Confirm needle-thread format |
The factory reference 856HR1750 appears in the supplier’s technical documentation (official product data sheet); the code is not verifiable in public web catalogues of the original manufacturer, so direct confirmation with the manufacturer is recommended before use in tender specifications.
Selection tips and variants of interest
- For the same HR17 format in improved quality, see the Premisut Prime 5/0 version (ref. P856HR1750, SKU AMP856HR1750).
- If you require a larger size with the same 17 mm needle, the Premisut line offers the 3/0 format (ref. 856HR1730, SKU AM856HR1730).
- The line is also available in white and in double needle formats (2×HR17) and mixed boxes of 10 threads (5 green and 5 white) of 75 cm.
- Always verify the compatibility of the needle (curvature 1/2, cylindrical body, conical Taperpoint point) and the USP size before substituting one reference for another in the operating theatre.
- Remember that this article is sold in boxes of 12 units with a minimum order of 30 boxes; consult our technical department for the conditions for contracts and tenders.