NYLON PREMISUT Prime 7/0 (EP 0.5) Suture · ⅜ Circle Triangular Point Precision Reverse Cutting XDS 8 mm Needle (Square Body) · Black Thread 45 cm · Non-Absorbable Monofilament (Ref. P641XDS870)

131,39 €

Non-absorbable monofilament nylon suture (polyamide 6/6.6) from the PREMISUT Prime range: USP 7/0 (metric EP 0.5) gauge, black 45 cm thread, uncoated and unfluted, mounted with ⅜ circle needle with triangular point, extra-long precision reverse cutting edge and 8 mm square body (XDS 8 Prime profile). Very smooth passage through tissue, minimal tissue reaction and wound support for more than three months due to gradual encapsulation. Ideal for approximation of soft tissues, ligatures, plastic and cosmetic surgery, ophthalmology and neurosurgery. Sterilised by ethylene oxide, single-use, in a box of 12 individual sachets with batch traceability. Factory reference P641XDS870 · SKU Cahnos AMP641XDS870.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP641XDS870

Description

1. Commercial Introduction

The NYLON PREMISUT Prime Suture is the precision reference from Cahnos for operating theatres, aesthetic surgery clinics, purchasing centres and tenders that require a non-absorbable suture with predictable behaviour. This presentation mounts a ⅜ circle needle with a triangular, extra-long precision reverse cutting point and a square body of 8 mm (XDS 8 Prime profile) on a black monofilament suture of 45 cm in USP 7/0 gauge: the microsurgery format par excellence for fine skin, ophthalmology, neurosurgery and plastic and cosmetic surgery. The Prime finish guarantees a homogeneous surface, low tissue reactivity and reliable knot retention, with batch traceability for hospital purchasing management.

2. Technical Explanation

The suture is made of uncoated monofilament nylon (polyamide 6 or 6.6), a synthetic polymer with a smooth surface that offers very smooth sliding through tissue, without wicking effect, with minimal bacterial adherence and low tissue reaction. Being non-absorbable, it does not degrade by enzymatic action: it undergoes gradual encapsulation by connective tissue and maintains tensile strength for more than three months, comfortably covering the critical healing phase in tissues subjected to prolonged tension.

The XDS 8 Prime needle (⅜ circle, triangular extra-long precision reverse cutting point with long cutting edge and square body of 8 mm) concentrates the cutting edge at the tip and prevents the cut from widening in the tissue, reducing tearing and improving the aesthetics of the scar. The square body provides maximum stability in the needle holder. The USP 7/0 gauge (metric EP 0.5) is one of the finest in the range, ideal for maximum precision procedures, and the black colour ensures immediate contrast of the suture on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

Brand / Quality Premisut Prime (premium range)
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament, smooth non-grooved surface
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / USP size USP 7/0 (metric EP 0.5); conforming to USP gauges and European Pharmacopoeia
Approximate thread diameter 0.050 – 0.069 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture)
Thread length 45 cm (free end, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ⅜ circle (3/8 circular)
Tip type Triangular reverse cutting, extra-long precision (Reverse Extra Cutting)
Needle body Square, maximum stability in needle holder
Needle size 8 mm (XDS 8 Prime profile)
Configuration Single needle (1 × 45 cm)
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, plastic and cosmetic surgery, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Factory reference P641XDS870
Reference Cahnos (SKU) AMP641XDS870

3.1. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
7/0 0.5 0.050 – 0.069 mm

3.2. Premisut Prime XDS family in nylon (⅜ circle, square body, precision reverse cutting)

Needle profile USP size Thread Reference
XDS 8 Prime 7/0 1 × 45 cm (black) P641XDS870 · AMP641XDS870 (this product)
XDS 11 Prime 7/0 1 × 45 cm (black) P641XDS1170 · AMP641XDS1170
XDS 11 Prime 7/0 1 × 75 cm (black) P642XDS1170 · AMP642XDS1170
XDS 11 Prime 6/0 1 × 45 cm (black) P641XDS1160 · AMP641XDS1160
XDS 13 Prime 6/0 1 × 45 cm (black) P641XDS1360 · AMP641XDS1360
XDS 16 Prime 6/0 1 × 45 cm (black) P641XDS1660 · AMP641XDS1660

4. Equivalences and Cross-References

The reference P641XDS870 corresponds to the official nomenclature of the Premisut Prime range (XDS 8 profile, extra-long precision reverse cutting needle with square body of 8 mm, USP 7/0 gauge, black suture of 45 cm) and Cahnos markets it keeping the factory reference without altering characters: no digit should be added, removed or reordered when ordering or tendering. Black non-absorbable monofilament nylon is one of the most standardised permanent suture families on the market (commercially type ‘Ethilon’).

There is no manufacturer-validated equivalence table that cross-references this reference with other brands; comparisons between brands are functional, at category level, and not interchangeable 1:1, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) ETHILON® – black monofilament nylon, 7-0, 45 cm (18″), P-1 Prime needle of 11 mm ⅜ circle, reverse cutting 1696G (confirmed in official Ethicon EPC catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), gauge 7/0 (EP 0.5), black colour, length 45 cm and radius ⅜; the needle differs: P-1 Prime reverse cutting of 11 mm versus XDS 8 with extra-long cutting edge and square body of 8 mm. Verify IFU before substituting.
Medtronic (Covidien) MONOSOF™ – black monofilament nylon, 7-0, 45 cm (18″), P-10 needle of 11 mm ⅜ circle, premium reverse cutting SN-3686 (confirmed in Medtronic/Covidien catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) Same material (nylon 6 and 6.6), gauge 7/0, black colour, length 45 cm and radius ⅜; the finish differs (P-10 premium reverse cutting of Surgalloy of 11 mm versus XDS 8 Prime with extra-long cutting edge and square body). Confirm IFU.
B. Braun DAFILON® – black polyamide 6.6 monofilament, 7/0 (metric 0.5), 45 cm, DSMP11 needle (⅜ circle, reverse cutting with precision point of 11 mm) C0977212 (confirmed in official B. Braun catalogue and GUDID record) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6.6 dyed black), gauge 7/0 (EP 0.5), length 45 cm and radius ⅜ with precision point; the needle size differs (DSMP11 of 11 mm versus XDS 8 mm with square body and extra-long edge). Verify IFU before substituting.

Other comparable houses in the segment to consider: the black monofilament nylon range from Serag-Wiessner (polyamide, used in microsurgery and ophthalmology). For the exact 7/0 black 45 cm configuration with an 8 mm reverse cutting needle, the specific code must be confirmed with the distributor and against the IFU before any substitution.

Mandatory technical note: there is no manufacturer-validated equivalence table that cross-references this reference with other brands. Comparisons with ETHILON®, MONOSOF™ or DAFILON® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution. This needle geometry (XDS 8 Prime, USP 7/0, 45 cm) is only safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence.

5. Selection tips and variants of interest

Tissue to suture: the USP 7/0 (metric 0.5) gauge is among the finest in the catalogue and the choice for microsurgery on very delicate planes (ophthalmology, neurosurgery) and fine skin. The precision XDS needle with extra-long cutting edge and square body reduces tearing and improves scar aesthetics, being especially valued in plastic and cosmetic surgery.

Thread length: 45 cm is the standard operating theatre measure and offers a good margin for passes and knots in reduced surgical fields; if the protocol requires more strand per unit, the same precision needle configuration is offered in higher profiles of the XDS family.

Variant / Reference Description
AMP641XDS1170 NYLON Prime XDS 11 mm 7/0 black 45 cm (same gauge and presentation, needle with longer length)
AMP642XDS1170 NYLON Prime XDS 11 mm 7/0 black 75 cm (same profile and gauge, longer thread length)
AMP641XDS1160 NYLON Prime XDS 11 mm 6/0 black 45 cm (same family, gauge 6/0)
AMP731XDS870 POLYPROPYLENE Prime XDS 8 mm 7/0 blue 45 cm (same XDS 8 needle, another non-absorbable material)
AMP641XHS880 NYLON Prime XHS 8 mm 8/0 black 45 cm (½ circle needle, same precision reverse cutting family)
AMP541DS870-2 SILK PREMISUT 2xDS 8 mm 7/0 black braided 45 cm (double needle, same gauge, another material)

Same needle, another material: if you require a non-absorbable thread with an identical XDS 8 needle profile in polypropylene (blue), consider reference AMP731XDS870. Larger needle body: for somewhat deeper access, the same configuration in XDS 11 mm or XDS 13 mm. Another curvature: if the protocol prefers a ½ circle needle, consult the XHS family in the catalogue.

Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P641XDS870 and the batch number for traceability in the operating theatre. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.

Additional information

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Thread structure

Monofilament, non-grooved surface

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

7/0 (metric EP 0.5)

Thread diameter

0.050 – 0.069 mm (according to USP Pharmacopoeia)

Needle shape

⅜ circle (3/8 circular)

Needle type

Triangular point, extra-long reverse precision cutting (Reverse Extra Cutting)

Needle size

8 mm (XDS 8 Prime profile)

Needle body

Square

Sterilisation

Ethylene oxide (EO)

Use

Single use, do not re-sterilise

Indications

Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery

Presentation

Box of 12 units (individual sterile sachets)

Manufacturer reference

P641XDS870

Medida de aguja

XDS 8

Usp

7/0

Color

Black

Medida de hilo

45 cm

Tipo de aguja

Precision triangular

Forma de aguja

3/8 circle

Calidad sutura

Prime