Description
1. Commercial Introduction
The NYLON PREMISUT PRIME Suture is the reference choice for operating theatres, aesthetic surgery clinics, purchasing centres and tenders that need a non-absorbable thread with predictable behaviour and a needle capable of penetrating skin and dense tissues with total control. This presentation mounts a ⅜ circle needle with a triangular point with conventional precision cutting (extra cutting) and a square body of 16 mm —XNS 16 Prime profile— on a black monofilament thread of 75 cm in USP 6/0 gauge: the classic format for closing fine skin, ophthalmology, neurosurgery and plastic and cosmetic surgery. Sterile, single-use product with batch traceability, presented in B2B format in a box of 12 units in individual envelopes.
2. Technical Explanation
Nylon or polyamide (6 or 6.6) is presented as uncoated, non-grooved monofilament: lacking interstices and wicking effect, it offers very smooth sliding through tissue, does not favour bacterial adherence or the formation of sinuses in wounds at risk of contamination, and minimises thread extrusion. It is not absorbed or degraded by tissue enzymes: it maintains its tensile strength for a prolonged period (according to USP and European Pharmacopoeia gauges) and is gradually encapsulated by connective tissue, helping the wound for more than three months.
The XNS 16 Prime needle (⅜ circle, triangular point with conventional precision cutting with long cutting edge and square body) penetrates firm tissues such as skin, mucosa and fibrous planes cutting with a clean and controlled path, reducing resistance to passage and trauma, with excellent stability in the needle holder thanks to its square body. The USP 6/0 gauge (metric EP 0.7) is one of the finest in the range, ideal for delicate procedures requiring maximum precision. The black colour guarantees immediate contrast of the thread on the surgical field. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer / distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated, dyed black |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| USP gauge / size | USP 6/0 (metric EP 0.7); conforms to USP and European Pharmacopoeia sizes |
| Approximate thread diameter | 0.070 – 0.099 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 75 cm (1 suture with 1 needle per unit) |
| Thread colour | Black (high visibility in surgical field) |
| Needle shape | ⅜ circular (3/8 circle) |
| Needle type | Triangular point, conventional precision cutting (extra cutting), long cutting edge |
| Needle body | Square (maximum stability in the needle holder) |
| Needle size | 16 mm (XNS 16 Prime profile) |
| Number of needles | 1 (single-armed) |
| Manufacturing quality | Prime (premium range) |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P642XNS1660 |
| Reference Cahnos (SKU) | AMP642XNS1660 |
3.2. Gauge conformity (indicative according to USP Pharmacopoeia, synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 6/0 | 0.7 | 0.070 – 0.099 mm |
3.3. Premisut Prime XNS family in nylon (⅜ circle, square body, triangular point conventional precision cutting)
| Needle profile | USP size | Thread | Reference |
| XNS 13 Prime | 6/0 | 1 × 45 cm (black) | P641XNS1360 |
| XNS 16 Prime | 6/0 | 1 × 45 cm (black) | P641XNS1660 |
| XNS 16 Prime | 6/0 | 1 × 75 cm (black) | P642XNS1660 (this product) |
| XNS 16 Prime | 5/0 | 1 × 45 cm (black) | P641XNS1650 |
| XNS 16 Prime | 5/0 | 1 × 75 cm (black) | P642XNS1650 |
| XNS 19 Prime | 4/0 | 1 × 45 cm (black) | P641XNS1940 |
| XNS 26 Prime | 6/0 | 1 × 45 cm (black) | P641XNS2660 |
| XNS 26 Prime | 5/0 | 1 × 45 cm (black) | P641XNS2650 |
4. Equivalences and Cross-References
The reference P642XNS1660 corresponds to the official nomenclature of the Premisut Prime range (XNS 16 Prime profile, ⅜ needle with triangular point of conventional precision cutting, square body of 16 mm, USP 6/0 gauge, black thread of 75 cm). Cahnos markets the product keeping the factory reference without altering characters: no digit should be added, removed or reordered when ordering or tendering.
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands. The following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution. The XNS 16 Prime geometry (extra cutting with square body) is only safely interchangeable within the Premisut system itself.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (Johnson & Johnson MedTech) | ETHILON® – black nylon monofilament, 6-0, 45 cm (18″), PC-3 ⅜ circle needle of 16 mm, conventional precision cutting PRIME | 1866G (verified in official Ethicon EPC catalogue, GUDID and authorised distribution) | Comparable by category (not interchangeable 1:1) | Same material (polyamide 6/6.6), gauge 6/0 (0.7), black colour, ⅜ radius, 16 mm needle and same family of conventional precision point PRIME; the thread length differs (45 cm vs 75 cm). Verify presentation and IFU before substituting. |
| B. Braun (Aesculap) | DAFILON® – uncoated polyamide monofilament, USP 6/0 (EP 0.7), 75 cm, DS16 ⅜ circle needle triangular point of 16 mm | C0935115 (verified in official B. Braun catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), gauge 6/0, diameter, length of 75 cm, ⅜ radius and 16 mm triangular needle; differences: blue colour vs black and type of sharpening (reverse cutting DS16 vs conventional precision cutting XNS16). Confirm geometry and IFU. |
Mandatory technical note: there is no equivalence table validated by the manufacturer that cross-references this reference with other brands. The comparisons with ETHILON® and DAFILON® are functional, at category level, and must be confirmed against the technical data sheet or IFU of each manufacturer before use in tendering or direct substitution. Other homologous families on the market (e.g. MONOSOF™ from Medtronic or DemeLON™ from DemeTech) require case-by-case verification of gauge, length and needle geometry. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
Tissue to suture: the XNS needle with conventional precision cutting and square body is indicated for skin, mucosa and fibrous planes that require firm penetration with minimal trauma; for lax, vascular or well-irrigated tissues, the same Premisut range offers conical point needles (e.g. nylon HR 16 and HR 20). The USP 6/0 gauge (metric 0.7) is the microsurgery choice for very delicate planes (ophthalmology, neurosurgery) and fine skin.
Thread length: 75 cm offers greater margin for passes and knots in wide surgical fields; if the protocol requires less thread, the 45 cm variant is available with the same XNS 16 Prime 6/0 needle (ref. P641XNS1660).
Other geometries and materials: if you prefer a precision reverse cutting triangular point, the XDS Prime family is available (e.g. AMP642XDS1660, XDS16 in 6/0 black 75 cm); if the protocol requires a non-absorbable braided thread with the same XNS 16 needle profile, the range offers Premisut Prime silk in 6/0 (e.g. AMP541XNS1660). Unifying the supplier across the entire suture portfolio enables B2B volume conditions.
| Variant / Reference | Description |
| AMP641XNS1660 | NYLON Prime XNS 16 mm – 6/0 black – 45 cm |
| AMP641XNS1360 | NYLON Prime XNS 13 mm – 6/0 black – 45 cm |
| AMP641XNS2660 | NYLON Prime XNS 26 mm – 6/0 black – 45 cm |
| AMP642XNS1650 | NYLON Prime XNS 16 mm – 5/0 black – 75 cm |
| AMP642XDS1660 | NYLON Prime XDS 16 mm (reverse cutting) – 6/0 black – 75 cm |
| AMP541XNS1660 | SILK Prime XNS 16 mm – 6/0 black – 45 cm |
Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference P642XNS1660 and the batch number for traceability in the operating theatre and in case of complaint. For annual contracts, tenders or hospital supply agreements, contact the technical-commercial team at Cahnos.