We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

NYLON Suture PREMISUT Prime 3/0 Black 75 cm | ⅜ Circle Triangular Reverse Cutting Needle DS26 Prime – Box of 12 units (SKU AMP641DS2630)

13,83 €

Non-absorbable surgical suture of nylon (polyamide 6/6.6) in uncoated black monofilament, USP 3/0 gauge (metric EP 2) and 75 cm thread, from the premium range PREMISUT Prime. It features a ⅜ circle needle with reverse cutting triangular point DS of 26 mm, designed for clean passage and firm knotting in skin, mucous membranes and soft tissues. Sterilised by ethylene oxide, single-use, with maintained tensile strength for more than three months thanks to its gradual encapsulation. Presentation in a box of 12 units. Indicated for soft tissue approximation, ligatures, ophthalmology and neurosurgery. B2B sale with batch traceability.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP641DS2630

Description

1. Commercial Introduction

The NYLON PREMISUT Prime 3/0 black 75 cm suture with DS26 needle is the reference solution for closing soft tissues when a high-performance permanent suture with predictable clinical behaviour is required. It combines a smooth-surface polyamide monofilament with a ⅜ circle reverse cutting triangular needle of 26 mm, ideal for general surgery, ophthalmology, neurosurgery and plastic surgery professionals, and for purchasing centres that need full traceability and stable supply. Sterile, ready-to-use product, supplied in a box of 12 units in individual pouches. SKU Cahnos: AMP641DS2630.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue permanently: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the suture surface is smooth: it slides easily, reduces the sawing effect, minimises bacterial adherence compared with multifilaments and promotes firm, stable knotting.

The DS26 Prime needle is a triangular reverse cutting point: the cutting edge is concentrated on the outer face of the arc and cuts outward from the wound, preventing tearing of the skin edge, a behaviour especially valued in skin and firm tissues of medium consistency. The USP 3/0 (metric EP 2) gauge offers the optimal balance between fineness and strength for skin closures and ligatures, and the 75 cm of suture provides sufficient length for medium-sized procedures or continuous sutures.

3. Technical Specifications

Parameter Specification
Brand / Quality Premisut Prime (premium range)
Thread material Nylon (polyamide 6 or 6.6), uncoated monofilament
Structure Monofilament, non-grooved surface
Absorption Non-absorbable; gradual encapsulation, retains tensile strength for more than 3 months
Gauge USP 3/0 (metric EP 2), in accordance with USP and European Pharmacopoeia gauges.
Thread length 75 cm
Colour Black (high visibility in surgical field)
Needle shape ⅜ circle (3/8 circular)
Tip type Triangular, reverse cutting
Needle size DS26 Prime (26 mm)
Swaged 1 needle per unit
Sterilisation Ethylene oxide (EtO), sterile; single use, do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Presentation Box of 12 units (individual sterile sachets)
Reference Cahnos (SKU) AMP641DS2630

Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture):

USP size Metric measurement (EP) Approximate thread diameter
3/0 2 0.20 – 0.249 mm

PREMISUT Prime family with reverse cutting DS needle (available variants):

Needle profile USP size Thread SKU Cahnos
DS26 Prime 3/0 1 × 75 cm (black) AMP641DS2630 (this product)
DS26 Prime 3/0 1 × 45 cm (black) AMP642DS2630
DS26 Prime 3/0 2 × 75 cm (black) AMP642DS2630.2
DS26 Prime 4/0 1 × 45 cm (black) AMP641DS2640
DS26 Prime 2/0 1 × 45 cm (black) AMP641DS2620
DS24 Prime 3/0 1 × 45 cm (black) AMP641DS2430

4. Equivalences and Cross-References

The reference AMP641DS2630 corresponds to the nomenclature of the Premisut Prime range (DS26 profile, triangular reverse cutting point, USP 3/0 gauge, black 75 cm suture). Non-absorbable black nylon monofilament is one of the most standardised permanent suture families on the market, but there is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparisons are functional, at category level, and have been verified against official catalogues and authorised distribution. They must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Ethicon (J&J MedTech) ETHILON™ – black nylon monofilament, 3-0, 75 cm, 26 mm FS needle, ⅜ circle, reverse cutting EW320BG Comparable by category (not interchangeable 1:1) Code confirmed in official Ethicon EMEA catalogue and authorised distribution. It matches in material (polyamide 6), gauge 3/0, black colour, length 75 cm, ⅜ curvature and needle size of 26 mm with reverse cutting point; the needle profile differs (standard FS vs DS Prime). Box of 12. Verify IFU before substituting.
B. Braun DAFILON® – polyamide monofilament, 3/0 (EP 2), 75 cm, DS24 needle, ⅜ circle, reverse cutting C0935352 Comparable by category (not interchangeable 1:1) Code confirmed in official B. Braun catalogue. Same material (polyamide), gauge (EP 2) and length (75 cm) with reverse cutting needle; colour (blue vs black) and needle (DS24 of 24 mm vs DS26 of 26 mm) differ. The black variant of Dafilon (polyamide 6.6) is used in ophthalmology and microsurgery; confirm the black colour code with the manufacturer.
Medtronic (Covidien) MONOSOF™ – black nylon monofilament, 3-0, 75 cm (30″), C-17 needle, ⅜ circle, reverse cutting SN-673 Comparable by category (not interchangeable 1:1) Code confirmed in Medtronic catalogue and authorised distribution. Same material (nylon), gauge 3/0, black colour and length 75 cm with reverse cutting geometry; the needle differs (C-17 vs DS26 of 26 mm), which changes handling ergonomics. Confirm commercial presentation before substituting.

Closing statement: there is no manufacturer-validated equivalence table for this configuration; check the technical data sheet or IFU of the alternative manufacturer for the exact gauge, suture length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. Consult the technical department of Cahnos to validate any equivalence.

5. Selection tips and variants of interest

  • Tissue to suture: the USP 3/0 (EP 2) gauge offers the optimal balance between fineness and strength for skin, subcutaneous tissue and soft tissues with medium tension. The DS26 reverse cutting needle penetrates firm, non-distensible tissues without tearing the puncture bed, being especially indicated in ophthalmology, neurosurgery and ligatures; for finer planes consider the 4/0 from the same family.
  • Thread length: this reference is 75 cm; the same DS26 Prime needle is available with 45 cm thread (AMP642DS2630) and in double format 2×75 cm (AMP642DS2630.2) for longer procedures or continuous suturing.
  • Portfolio unification: the same DS26 Prime needle is offered in USP 2/0, 3/0 and 4/0 to unify supplier across the entire range of non-absorbable sutures. If an extra-long precision cutting edge with square body (XDS profile) is required, the XDS26 family is available (e.g. AMP642XDS2630) for plastic and cosmetic surgery; for a 24 mm needle, reference AMP641DS2430.
  • Sterility verification: sterile product by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use, and keep the reference and batch number for traceability in the operating theatre.
  • B2B conditions: for volume hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Material

Nylon (polyamide 6 or 6.6), uncoated monofilament

Structure

Monofilament, non-grooved surface

Absorption

Non-absorbable (gradual encapsulation, tissue support > 3 months)

Gauge

USP 3/0 (metric EP 2); approximate diameter 0.20–0.249 mm

Needle shape

3/8 circle (⅜ circular)

Tip type

Triangular, reverse cutting

Needle size

DS26 Prime (26 mm)

Swaged

1 needle

Quality

Prime (premium range)

Sterilisation

Ethylene oxide (EtO), single use

Presentation

Box of 12 units (individual sterile sachets)

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Medida de aguja

DS 26

Usp

3/0

Color

Black

Medida de hilo

45 cm, 75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

3/8 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “NYLON Suture PREMISUT Prime 3/0 Black 75 cm | ⅜ Circle Triangular Reverse Cutting Needle DS26 Prime – Box of 12 units (SKU AMP641DS2630)”

Your email address will not be published. Required fields are marked *