Description
1. Commercial Introduction
The NYLON SUTURE PREMISUT USP 2 (factory ref. 643DS9002, SKU AM643DS9002) is the reference in the standard range of non-absorbable sutures from Cahnos for procedures requiring a permanent thread of long length and a long-bodied reverse cutting needle. This configuration combines a nylon monofilament (polyamide 6 or 6.6), identifying black colour, USP 2 gauge and 90 cm of fluted thread, mounted on a ⅜ circle needle with a 90 mm reverse cutting triangular point (DS90 profile). It is a common choice in general surgery, ophthalmology and neurosurgery departments, as well as in purchasing centres and tenders that require a high-performance permanent thread with predictable clinical behaviour and full traceability. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling.
The DS90 needle, 90 mm, has a ⅜ circle curvature with a reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, preserving the skin edge and preventing the cut from widening in the puncture bed, facilitating passage through firm, non-distensible tissues. Its great length makes it especially suitable for deep approaches, muscle planes and suturing of wide fields. The USP 2 gauge (metric EP 5) provides high resistance for tissues under medium-high tension and retention sutures, while the 90 cm of thread offers sufficient length for continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | Premisut (standard range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 2 (metric EP 5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.45 – 0.499 mm (according to USP Pharmacopoeia, synthetic non-absorbable suture) |
| Thread length | 90 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 3/8 circle (⅜ circular) |
| Tip type | Reverse cutting triangular |
| Needle size | DS 90 (90 mm) |
| Configuration | 1 needle per unit, grooved thread |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, skin closure under tension, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | 643DS9002 |
| Reference Cahnos (SKU) | AM643DS9002 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 2 | 5 | 0.45 – 0.499 mm |
3.3. Premisut DS90 family (⅜ circle needle, 90 mm, triangular reverse cutting point, black thread 90 cm)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| DS90 | 3/0 | 1 × 90 cm (black) | 643DS9030 / AM643DS9030 |
| DS90 | 2/0 | 1 × 90 cm (black) | 643DS9020 / AM643DS9020 |
| DS90 | 0 | 1 × 90 cm (black) | 643DS9010 / AM643DS9010 |
| DS90 | 1 | 1 × 90 cm (black) | 643DS9001 / AM643DS9001 |
| DS90 | 2 | 1 × 90 cm (black) | 643DS9002 / AM643DS9002 (this product) |
| DS90 Prime | 2 | 1 × 90 cm (black, Prime range) | P643DS9002 / AMP643DS9002 |
4. Equivalences and Cross-References
Reference 643DS9002 corresponds to the official nomenclature of the Premisut range (DS90 profile: ⅜ circle needle with 90 mm reverse cutting triangular point, USP 2 gauge, black fluted 90 cm thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially of the ‘Ethilon’ type).
There is no equivalence table validated by the manufacturer that cross-references this reference with other brands; the following comparisons are functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Dafilon® – uncoated polyamide monofilament, USP 2 (EP 5), 100 cm thread, DS90 needle 90 mm (⅜ circle, reverse cutting) | C0934933 / G0934933 (verified in official B. Braun catalogue and GUDID 04038653931668) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), USP 2 gauge (EP 5), ⅜ curvature, reverse cutting point and DS90 needle 90 mm; they differ in colour (blue vs black) and thread length (100 cm vs 90 cm). |
| Laboratory Aragó | Blue nylon monofilament, USP 2, 90 mm triangular needle in ⅜ circle (TB70/TB75 profile) | 20300 (reference published in authorised distribution; confirm thread length and exact point geometry with the manufacturer) | Not verified | They match in material (polyamide), USP 2 gauge and 90 mm needle length; they differ in colour (blue vs black), sterilisation (gamma rays vs ethylene oxide) and thread length, which is published variably (50–100 cm) depending on presentation. Requires official confirmation. |
Mandatory closing sentence: there is no equivalence table validated by the manufacturer for this configuration; check in the technical data sheet or IFU of the alternative manufacturer the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (DS90, USP 2, 90 cm) is only fully safely interchangeable within the Premisut system itself. Consult the technical department of Cahnos to validate any equivalence. Other homologous families on the market to review property by property before any substitution: Ethicon ETHILON (black nylon monofilament) and SMI/B. Braun SUPRAMID (polyamide pseudomonofilament).
5. Selection tips and variants of interest
Tissue to suture: USP 2 gauge (EP 5) offers maximum resistance for firm subcutaneous tissue, fasciae, aponeuroses, skin closures under tension and retention sutures. The reverse cutting needle passes through dense tissues without tearing the puncture bed; due to its length, the DS90 profile is especially indicated for deep approaches and wide fields. For finer planes, consider 3/0 or 2/0 from the same family (Ref. 643DS9030 and 643DS9020).
Variants of the same DS90 needle: the same 90 mm needle is available in USP 3/0 (Ref. 643DS9030), USP 2/0 (Ref. 643DS9020), USP 0 (Ref. 643DS9010) and USP 1 (Ref. 643DS9001), allowing a single supplier for the entire range of non-absorbable long-needle sutures. If the procedure requires maximum sharpness precision, the same geometry and gauge are available in the Prime range (Ref. P643DS9002, SKU AMP643DS9002). For smaller surgical fields, consider shorter needles from the same line (e.g. DS40 of 40 mm, Ref. 643DS4002, with 90 cm thread).
Thread length: this reference is 90 cm (series 643); when the procedure requires a shorter length, presentations of the same needle are available with 75 cm thread (series 642).
Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 643DS9002 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B volume conditions, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.