Description
1. Commercial Introduction
The NYLON PREMISUT Prime suture is the reference in the premium range of non-absorbable sutures from Cahnos for procedures requiring precision, clean passage and minimal tissue damage. This configuration combines a nylon monofilament thread (polyamide 6 or 6.6), black in colour, USP 5/0 gauge and 45 cm in length, with a ½ circular needle with an extra-long precision reverse cutting triangular point and a 13 mm square body (XHS 13 Prime profile).
It is the usual choice in ophthalmology, neurosurgery, plastic and cosmetic surgery, dermatology and general surgery departments, as well as for purchasing centres and tenders seeking a high-performance permanent thread with predictable clinical behaviour and full traceability. Sterile, ready-to-use product, supplied in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament with a non-grooved surface, the thread slides easily through tissues, has no wicking effect, reduces bacterial drag compared with multifilaments and minimises the inflammatory reaction, an essential behaviour in cosmetic sutures and delicate planes.
The XHS 13 Prime needle features a ½ circle curvature with an extra-long precision reverse cutting triangular point and a square body: the cutting edge, with a long cutting edge, cuts in the opposite direction to the wound bed, creating a clean entry hole that preserves the skin edge and prevents the cut from widening, while the square body optimises grip in the needle holder and torque transmission. The USP 5/0 gauge (metric EP 1) offers the optimal balance between fineness and strength for delicate tissues, and the 45 cm of thread provide the standard operating theatre length for passes and knots. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
Data verified according to the technical data sheet and instructions for use of the manufacturer/distributor (Cahnos S.L.).
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth non-grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / size | USP 5/0 (metric EP 1), conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.100 – 0.149 mm |
| Thread length | 45 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Tip type | Extra-long precision reverse cutting triangular (long cutting edge) |
| Needle body | Square (maximum stability in the needle holder) |
| Needle size | 13 mm (XHS 13 Prime profile) |
| Configuration | 1 needle per unit, single armed, non-grooved |
| Sterilisation | Ethylene oxide (EO), sterile |
| Use | Single-use, not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology, neurosurgery, plastic and cosmetic surgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Factory reference | P641XHS1350 |
| Reference Cahnos (SKU) | AMP641XHS1350 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 5/0 (this product) | 1 | 0.100 – 0.149 mm |
3.3. PREMISUT Prime XHS family (½ circle needle, extra-long precision reverse cutting triangular point, square body)
| Needle profile | USP size | Thread | Reference |
|---|---|---|---|
| XHS 8 Prime | 8/0 | 1 × 45 cm (black) | P641XHS880 / AMP641XHS880 |
| XHS 13 Prime | 5/0 | 1 × 45 cm (black) | P641XHS1350 / AMP641XHS1350 (this product) |
| XHS 17 Prime | 5/0 | 1 × 75 cm (black) | P642XHS1750 / AMP642XHS1750 |
| XHS 22 Prime | 3/0 | 1 × 45 cm (black) | P641XHS2230 / AMP641XHS2230 |
| XHS 48 Prime | 1 | 1 × 100 cm (black) | P647XHS4810 / AMP647XHS4810 |
4. Equivalences and Cross-References
The reference P641XHS1350 corresponds to the official nomenclature of the PREMISUT Prime range (XHS 13 Prime profile: ½ circle needle with extra-long precision reverse cutting triangular point and 13 mm square body, USP 5/0 gauge, 45 cm black thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Non-absorbable black monofilament nylon is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’).
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; the following comparison is functional, at category level, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ETHILON – black monofilament nylon, 5-0, 45 cm (18″), 16 mm PS-4 needle, ½ circle, precision reverse cutting | 1661G (verified in official Ethicon EPC catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), gauge 5/0 (EP 1), black colour, ½ circle curvature, reverse cutting point family and thread length (45 cm); they differ in needle size (16 mm vs 13 mm), sharpening geometry (precision PS-4 vs XHS 13 Prime with extra-long edge and square body). Verify IFU before substituting. |
Other homologous families in the segment that must be reviewed property by property (material, gauge, ½ circle curvature, reverse cutting point family, needle length within tolerance, thread length, colour, 1-needle configuration and CE/MDR regulatory classification) before any substitution: DAFILON (B. Braun, monofilament polyamide), MONOSOF and DERMALON (Medtronic), DemeLON (DemeTECH), LUXAMID (LuxSutures) and the polyamide ranges from Serag-Wiessner. No code from these companies reproducing the exact combination XHS 13 Prime + USP 5/0 + 45 cm black thread with extra-long edge and square body has been found in public sources (GUDID/EUDAMED and official catalogues), so no third-party cross-reference codes are published without verification. The brands cited belong to their respective manufacturers and are mentioned solely as an equivalence reference.
There is no manufacturer-validated equivalence table; consult the technical department before use in tendering. This needle geometry (XHS 13 Prime, USP 5/0, 45 cm thread) is only fully safely interchangeable within the PREMISUT system itself.
5. Selection tips and variants of interest
- Tissue to suture: the USP 5/0 gauge (EP 1) offers the optimal balance between fineness and strength for skin, subcutaneous tissue and soft tissues with low-medium tension. The XHS 13 Prime needle with extra-long reverse cutting and square body penetrates firm, non-distensible tissues without tearing the puncture bed, being especially indicated in plastic, cosmetic, ophthalmology and neurosurgery; for higher tension planes consider the 3/0 from the same family.
- Needle length: the XHS 13 mm profile is the precision size for confined surgical fields. The same XHS Prime family offers profiles of 8, 17, 22 and 48 mm (references AMP641XHS880, AMP642XHS1750, AMP641XHS2230 and AMP647XHS4810), allowing the needle to be adjusted to the access and the plane without changing the system.
- Portfolio unification: the XHS Prime family allows supplier unification across the entire range of non-absorbable precision sutures with extra-long reverse cutting ½ circle needle. If the protocol allows another curvature, the range offers XDS profiles (⅜ circle, precision reverse cutting), such as reference AMP641XDS1350 (XDS 13 Prime 5/0 black 45 cm), for more superficial accesses with the same cosmetic result.
- Presentation and sterility: this reference is supplied in a box of 12 units in individual sterile sachets with batch traceability, the usual format for operating theatres, purchasing centres and tenders. Check the integrity of the blister and the expiry date before each use and keep reference P641XHS1350 together with the batch number for traceability.
- Storage: store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.