Description
1. Commercial Introduction
NYLON Suture PREMISUT 1/2 Cylindrical HR26 (Factory ref. 642HR2630 · SKU Cahnos AM642HR2630) is the standard reference in the PREMISUT range of non-absorbable nylon sutures for B2B supply: operating theatres, purchasing centres, general and specialist surgery departments, ophthalmology clinics and neurosurgery units. It combines a monofilament of polyamide 6 or 6.6 in identifying black colour, USP 3/0 gauge (metric EP 2) and a 75 cm uncoated strand, mounted on a ½ circle needle with cylindrical body and 26 mm taperpoint conical point (HR26 profile).
Sterile, ready-to-use product with full batch traceability, intended for hospital replenishment, tenders and volume contracts. Price per box of 12 individual sterile pouches.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical phase of wound healing. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. Its grooved finish improves knot retention, while the black colour ensures optimal contrast on the surgical field, especially in precision specialties.
The 26 mm HR26 needle features a ½ circle curvature with cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through soft tissues by separating the fibres without cutting them, making it especially suitable for fascia, peritoneum, muscle, conjunctiva and other soft, well-vascularised tissues where minimising trauma is sought. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
|---|---|
| Brand / Quality | PREMISUT (standard range) |
| Factory reference | 642HR2630 |
| Reference Cahnos (SKU) | AM642HR2630 |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Coating | None |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 3/0 (metric 2 / EP 2), conforming to USP gauges and European Pharmacopoeia |
| Approximate thread diameter | 0.20 – 0.249 mm |
| Thread length | 75 cm (1 needle per suture) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circular), cylindrical body |
| Tip type | Conical / Taperpoint, grooved |
| Needle size | HR 26 (26 mm), 1 needle per suture |
| Configuration | 1 needle, 1 suture of 75 cm per pack |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Not re-sterilisable |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 sterile individual sachets; batch traceability |
| Regulatory standard | Complies with USP/EP Pharmacopoeia; CE marking (MDR) |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
|---|---|---|
| 4/0 | 1.5 | 0.15 – 0.199 mm |
| 3/0 (this product) | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
| 0 | 3.5 | 0.35 – 0.399 mm |
The strand diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without exceeding the limits.
3.3. PREMISUT HR26 family (½ circle needle of 26 mm, taperpoint conical tip, black thread of 75 cm)
| Needle size | USP | EP | Colour | Suture length | Reference |
|---|---|---|---|---|---|
| HR 26 | 4/0 | 1.5 | Black | 75 cm | 642HR2640 |
| HR 26 | 3/0 | 2 | Black | 75 cm | 642HR2630 (this product) |
| HR 26 | 2/0 | 3 | Black | 75 cm | 642HR2620 |
| HR 26 | 0 | 3.5 | Black | 75 cm | 642HR2610 |
| HR 26 | 1 | 4 | Black | 75 cm | 642HR2601 |
The same HR26 conical needle is available in other gauges (USP 4/0, 3/0, 2/0, 0 and 1), in Prime version (refs. P642HR26xx) and in a double-thread presentation of 2×75 cm; the family continues with shorter (HR20) or longer (HR30, HR37, HR40) needle profiles depending on the required surgical path.
4. Equivalences and Cross-References
Reference 642HR2630 corresponds to the official nomenclature of the PREMISUT range (HR26 profile: ½ circle needle with 26 mm taperpoint conical point, USP 3/0 gauge, 75 cm black grooved thread) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.
Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). After comparing official manufacturer catalogues and regulatory databases (GUDID/FDA, EUDAMED), no reference from another manufacturer has been found that matches all the required fields for this configuration: material (polyamide 6/6.6), USP 3/0 gauge (EP 2), armed with 1 needle, ½ circle curvature, taperpoint conical point, 26 mm needle and 75 cm black strand. The references verified in official sources within the same 26 mm conical needle family correspond to other gauges or colours — for example, DAFILON® blue from B. Braun with HR26 needle in USP 2/0 (C0930423) and USP 0 (C0930431), confirmed on the manufacturer’s website, or the R-26 needle family from ATRAMAT® NYLON (R2642-75N in USP 2/0) —, therefore, despite their great geometric proximity, they are not 1:1 interchangeable with this black 3/0 reference without validation of the exact gauge.
Homologous families of non-absorbable nylon monofilament that must be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: ETHILON® (Ethicon / J&J MedTech), DAFILON® (B. Braun / Aesculap), MONOSOF™ and DERMALON™ (Medtronic / Covidien), DEMELON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures), SUPRAMID® (SMI) and ATRAMAT® NYLON (Internacional Farmacéutica). In these manufacturers, the exact HR26 configuration of 26 mm, USP 3/0, conical point and 75 cm black strand has not been verified in public sources; it must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer; consult the technical department before using in tendering. This needle geometry (HR26, USP 3/0, 75 cm thread) is only fully safely interchangeable within the PREMISUT system itself: the direct equivalent within the same manufacturer is the Prime range version of identical configuration and gauge (Ref. P642HR2630 · SKU AMP642HR2630). The brands cited belong to their respective manufacturers and are mentioned only as an equivalence reference.
5. Selection tips and variants of interest
Tissue to suture: USP 3/0 gauge (metric EP 2) offers the optimal balance between fineness and strength for subcutaneous tissue, skin, mucous membranes, soft tissues with low-medium tension and ligatures, always with a conical point needle to minimise tissue damage. For finer planes, consider USP 4/0 (Ref. AM642HR2640) with the same HR26 needle; for higher loads, USP 2/0 (Ref. AM642HR2620), USP 0 (Ref. AM642HR2610) or USP 1 (Ref. AM642HR2601).
Needle length: the 26 mm HR26 profile is the standard option for surgical fields with a reduced path (ophthalmology, minor surgery, neurosurgery). For deeper accesses, the HR30, HR37 or HR40 profiles are available with the same conical point family.
Alternative point: if the protocol requires a reverse cutting needle for skin or mucous membranes, the same gauge and length is available in the HS26 family (SKU AM642HS2630), always with prior validation of the technical data sheet.
Prime quality: if the procedure requires maximum sharpness consistency batch to batch, the PREMISUT Prime range offers the same geometry and gauge (Ref. P642HR2630 · SKU AMP642HR2630), a direct equivalent within the same manufacturer.
Sterility verification: product sterilised by ethylene oxide and for single use; check the integrity of the blister and the expiry date before each use, and keep reference 642HR2630 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight. For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.