We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

NYLON PREMISUT Prime Suture · ½ Circle Cylindrical Taperpoint Conical Point Needle 37 mm (HR37) · USP 0 (EP 3.5) · Black Monofilament Thread 2×75 cm · Non-Absorbable Polyamide · Box of 12 units (Ref. P642HR3710.2)

27,65 €

NYLON PREMISUT Prime non-absorbable monofilament suture (polyamide 6 or 6.6), USP 0 gauge (metric EP 3.5), black colour and double thread presentation 2 × 75 cm. It mounts a Prime needle of ½ circle, cylindrical body and taperpoint conical point of 37 mm (HR37 profile): the reference geometry for approximation of soft tissues, ligatures, ophthalmology and neurosurgery with minimal tissue trauma. Gradual encapsulation, wound support for more than 3 months and fluted finish for maximum knot retention. Sterile by ethylene oxide and single-use; box of 12 individual sachets. Factory ref. P642HR3710.2 · SKU Cahnos AMP642HR3710.2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AMP642HR3710.2

Description

1. Commercial Introduction

The NYLON SUTURE PREMISUT Prime 1/2 Cylindrical HR37 mm in USP 0 gauge (Factory ref. P642HR3710.2 · SKU Cahnos AMP642HR3710.2) is the reference in the premium range of Cahnos within non-absorbable nylon sutures for procedures requiring a permanent, manageable, high-performance thread, mounted on a cylindrical-body needle with a conical point. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP 0 gauge (metric EP 3.5) and a double 75 cm fluted uncoated strand, on a Prime ½-circle needle with a 37 mm taperpoint (HR37 profile).

It is a common choice in ophthalmology, neurosurgery, general surgery departments and in purchasing and tendering centres that need a permanent thread with predictable clinical behaviour, complete batch traceability and the maximum lot-to-lot consistency provided by Prime quality. Sterile, ready-to-use product, presented in a box of 12 individual sachets.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling in the surgical field, while the black colour ensures optimal contrast on the field.

The 37 mm HR37 Prime needle features a ½-circle curvature with a cylindrical body and conical point (taperpoint): the sharp point without cutting edges passes through tissues separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fascia, peritoneum, muscle, conjunctiva) where minimising trauma is sought. The double-thread presentation 2 × 75 cm allows continuous sutures or multiple stitches without re-threading, optimising performance in high-consumption surgical programmes. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical specifications and tables

3.1. General characteristics

Parameter Specification
Factory reference P642HR3710.2
Reference Cahnos (SKU) AMP642HR3710.2
Brand / Quality PREMISUT Prime (premium range)
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament, grooved finish
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges
Approximate thread diameter 0.35 – 0.399 mm
Thread length 2 × 75 cm (double strand, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape ½ circle (1/2 circular), cylindrical body
Tip type Conical / Taperpoint, grooved
Needle size HR 37 Prime (37 mm)
Configuration 2 needles per unit, 2 strands of 75 cm
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 sterile individual sachets; batch traceability

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
2/0 3 0.30 – 0.339 mm
0 3.5 0.35 – 0.399 mm
1 4 0.40 – 0.499 mm
2 5 0.45 – 0.499 mm

The thread diameter complies with the official USP Pharmacopoeia ranges for non-absorbable sutures, without extending their limits.

3.3. PREMISUT HR37 Prime family (½-circle 37 mm needle, taperpoint conical point, black thread)

Needle profile USP size Thread Reference
HR 37 Prime 1 1 × 75 cm (black) P642HR3701 / AMP642HR3701
HR 37 Prime 0 1 × 75 cm (black) P642HR3710 / AMP642HR3710
HR 37 Prime 0 2 × 75 cm (black, double thread) P642HR3710.2 / AMP642HR3710.2 (this product)
HR 37 Prime 2/0 2 × 75 cm (black, double thread) P642HR3720.2 / AMP642HR3720.2

The same HR37 conical needle is available in other gauges (USP 1, 2/0) and in shorter needle profiles (HR26, HR30) or longer ones (HR40, HR50, series 643) for procedures of shorter or longer length.

4. Equivalences and Cross-References

The reference P642HR3710.2 corresponds to the official nomenclature of the PREMISUT Prime range (HR37 profile: ½-circle taperpoint conical point needle of 37 mm, USP 0 gauge, black fluted 75 cm thread in double presentation) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering.

Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type «Ethilon»). There is no manufacturer-validated equivalence table cross-referencing this specific configuration (½-circle HR37 conical point needle of 37 mm, USP 0 gauge, black, double 75 cm strand) with references from other houses; therefore, the following matches are functional comparisons at category level and must not be treated as 1:1 interchangeable without prior technical validation. The cited codes have been checked against the official catalogue and the corresponding manufacturer’s GUDID/FDA regulatory databases.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) DAFILON® – uncoated polyamide monofilament, USP 2/0 (EP 3), blue 75 cm thread, 37 mm HR37 needle (½ circle, round body, conical point) C0930701 (verified in official B. Braun catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), ½-circle curvature, conical point family, needle size (HR37 of 37 mm, identical) and thread length (75 cm); they differ in gauge (USP 2/0 vs 0), thread colour (blue vs black) and presentation (1 thread vs 2 threads). Confirm IFU and CE/MDR classification before substituting.
Ethicon (J&J MedTech) ETHILON® – black nylon monofilament, USP 0, 36″ thread (≈ 91 cm), 48 mm CT-1 needle (½ circle, taperpoint conical point) 2808G (verified in official Ethicon catalogue and authorised distribution) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), USP 0 gauge (EP 3.5) and black colour; they differ in needle size (48 mm vs 37 mm, outside the ±1 mm tolerance) and thread length (≈ 91 cm vs 75 cm). Confirm IFU and CE/MDR classification before substituting.

Other homologous families on the market that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution are: Monosof™ and Dermalon™ (Medtronic / Covidien), DemeLON™ (DemeTECH), SERALON® (Serag-Wiessner), LUXAMID® (LuxSutures) and SUPRAMID® (SMI). No codes from these houses have been verified in public sources for the exact HR37 37 mm, USP 0, conical point and black 75 cm double-presentation configuration; they must be confirmed with the manufacturer before use in substitution or tendering.

There is no equivalence table validated by the manufacturer for this configuration; check the technical data sheet or instructions for use of the alternative manufacturer for the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) before using this information in tenders or direct substitution. This needle geometry (HR37 Prime, USP 0, double thread of 75 cm) is only safely interchangeable within the PREMISUT system itself. Consult the technical department at Cahnos to validate any equivalence.

5. Selection tips and variants of interest

Tissue to suture: the USP 0 gauge (metric EP 3.5) offers an optimal balance between strength and manageability for subcutaneous tissue, fasciae and soft tissues under moderate tension, always with a conical-point needle to minimise tissue damage. For finer planes, consider USP 2/0 (Ref. AMP642HR3720.2) and for higher loads USP 1 (Ref. AMP642HR3701) from the same Prime family.

Needle length: the HR37 profile of 37 mm covers medium-depth accesses. For smaller fields, the HR26 (Ref. AMP642HR2601) or HR30 (Ref. AMP642HR3001) family from the same Prime range is available; for longer fields, the HR40 (Ref. AMP642HR4001) or HR50 (Ref. AMP643HR5001) profile.

Double presentation: this reference provides 2 threads of 75 cm per pack, ideal for continuous sutures without re-threading or for distributing the material across two surgical fields. If the protocol only requires one strand, the same needle and gauge are available in a 1 × 75 cm presentation (Ref. AMP642HR3710).

Prime vs. standard quality: if the procedure requires maximum sharpness precision and batch-to-batch consistency, the Prime range offers this same geometry and gauge; if unit cost is a critical factor, the standard range (Ref. AM642HR3710) maintains the same dimensional specifications with standard sharpening performance.

Sterility verification: product sterile by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference P642HR3710.2 and batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.

For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team at Cahnos.

Additional information

Product line

PREMISUT Prime (premium range)

Manufacturer reference

P642HR3710.2

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Structure

Monofilament with grooved surface

Coating

None

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 0 (metric EP 3.5)

Thread diameter

0.35 – 0.399 mm

Thread length

2 × 75 cm (double strand)

Needle shape

1/2 circle (cylindrical body)

Tip type

Conical / Taperpoint, grooved

Needle size

HR 37 Prime (37 mm)

Configuration

2 needles per unit, 2 strands of 75 cm

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile, non-reesterilizable

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Presentation

Box of 12 sterile individual sachets

Regulatory standard

Complies with USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HR 37

Usp

0

Color

Black

Medida de hilo

2 × 75 cm

Tipo de aguja

Cylindrical

Forma de aguja

1/2 circle

Calidad sutura

Prime

Reviews

There are no reviews yet.

Be the first to review “NYLON PREMISUT Prime Suture · ½ Circle Cylindrical Taperpoint Conical Point Needle 37 mm (HR37) · USP 0 (EP 3.5) · Black Monofilament Thread 2×75 cm · Non-Absorbable Polyamide · Box of 12 units (Ref. P642HR3710.2)”

Your email address will not be published. Required fields are marked *