NYLON Non-Absorbable Suture PREMISUT · 1/2 Circle Reverse Cutting Triangular Needle HS36 (36 mm) · USP 2 (EP 5) · Black Thread 75 cm · Polyamide Monofilament · Box of 12 units (Ref. 642HS3602)

8,58 €

NYLON suture PREMISUT of polyamide monofilament non-absorbable and uncoated, in USP 2 (metric EP 5) and black grooved strand of 75 cm. It mounts a ½ circle needle with a reverse cutting triangular point of 36 mm (HS 36 profile): penetration into firm tissues preserving the skin edge, minimal tissue reaction and wound support for more than three months through gradual encapsulation. Indicated for approximation of soft tissues, ligatures, ophthalmology and neurosurgery. Sterile by ethylene oxide, single-use, with batch traceability; presentation in a box of 12 units. Manufacturer’s ref. 642HS3602 · SKU AM642HS3602.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AM642HS3602

Description

1. Commercial Introduction

The NYLON Suture PREMISUT 1/2 Triangular HS36 is the reference in the PREMISUT standard range for procedures requiring a high-performance permanent suture mounted on a medium-bodied reverse cutting needle. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP gauge 2 and 75 cm of uncoated fluted thread, with a ½ circle reverse cutting triangular point needle of 36 mm (HS 36 profile).

It is a common choice in general surgery, ophthalmology, neurosurgery departments and in purchasing and tendering centres that seek a permanent suture with predictable clinical behaviour, with complete lot traceability and an excellent balance between price and performance. Sterile product, ready to use, presented in a box of 12 units in individual sterile sachets.

2. Technical Explanation

Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. As it is an uncoated monofilament, the thread slides easily through tissues, reduces the wick effect and bacterial drag compared to multifilament, and minimises inflammatory reaction. The fluted finish of the strand improves knot retention and handling in the field.

The HS 36 needle of 36 mm features a ½ circle curvature with reverse cutting triangular point: the cutting edge cuts in the opposite direction to the wound, which preserves the skin edge and prevents the cut from widening in the puncture bed, facilitating passage through firm, non-distensible tissues. USP gauge 2 (metric EP 5) provides high tensile strength, suitable for fascia, aponeuroses, tension skin closures, ligatures and retention sutures, and the 75 cm of thread offer sufficient length for continuous sutures or several stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.

3. Technical Specifications

3.1. General characteristics

Parameter Specification
Brand / Quality PREMISUT (standard range)
Thread material Nylon monofilament (polyamide 6 or 6.6), uncoated
Thread structure Monofilament with grooved surface
Coating None
Absorption Non-absorbable; gradual encapsulation, wound support for more than 3 months
Gauge / Size USP 2 (metric EP 5), conforming to USP and European Pharmacopoeia calibres
Approximate thread diameter 0.45 – 0.499 mm
Thread length 75 cm (free end, without loop)
Thread colour Black identifier (high visibility in surgical field)
Needle shape 1/2 circle (½ circular), grooved
Tip type Triangular reverse cutting (Reverse Cutting)
Needle size HS 36 (36 mm)
Configuration 1 needle per unit, grooved thread
Sterilisation Ethylene oxide (EO) – sterile
Use Single-use, sterile. Do not re-sterilise
Indications Approximation of soft tissues, ligatures, ophthalmology and neurosurgery
Commercial presentation Box of 12 units (sterile individual sachets); batch traceability
Factory reference 642HS3602
Reference Cahnos (SKU) AM642HS3602
Regulatory standard Complies with USP/EP Pharmacopoeia; CE marking (MDR)

3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)

USP size Metric measurement (EP) Approximate thread diameter
0 3.5 0.35 – 0.399 mm
1 4.0 0.40 – 0.499 mm
2 (this product) 5.0 0.45 – 0.499 mm

3.3. PREMISUT HS 36 family (½ circle needle, 36 mm, reverse cutting triangular point, black thread 75 cm)

Needle profile USP size Thread Factory reference SKU Cahnos
HS 36 (standard) 0 1 × 75 cm (black) 642HS3610 AM642HS3610
HS 36 (standard) 1 1 × 75 cm (black) 642HS3601 AM642HS3601
HS 36 (standard) 2 1 × 75 cm (black) 642HS3602 AM642HS3602 (this product)
HS 36 Prime 0 1 × 75 cm (black) P642HS3610 AMP642HS3610
HS 36 Prime 1 1 × 75 cm (black) P642HS3601 AMP642HS3601
HS 36 Prime 2 1 × 75 cm (black) P642HS3602 AMP642HS3602

4. Equivalences and Cross-References

The reference 642HS3602 corresponds to the official nomenclature of the PREMISUT range (HS 36 profile: ½ circle reverse cutting triangular point needle of 36 mm, USP gauge 2, black fluted thread of 75 cm) and Cahnos markets it without altering characters: no digit should be added, removed or reordered when ordering or tendering.

Non-absorbable black nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’). There is no equivalence table validated by the manufacturer that cross-references this reference with other brands for the exact combination USP 2 + ½ circle reverse cutting needle of 36 mm + black strand of 75 cm. The following comparison is functional, at category level, verified against the manufacturer’s official catalogue, and must be confirmed against the technical data sheet or instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
B. Braun (Aesculap) DAFILON® blue – uncoated polyamide monofilament, USP 2 (EP 5), 75 cm, HR48 needle of 48 mm (½ circle) B0930750 (verified in official catalogue B. Braun) Comparable by category (not interchangeable 1:1) They match in material (polyamide 6/6.6), USP gauge 2 (EP 5), thread length (75 cm), ½ circle curvature and 1 needle armed; they differ in strand colour (blue vs. black), needle family (round body HR vs. reverse cutting HS) and needle length (48 mm vs. 36 mm). Confirm IFU and CE/MDR classification before substituting.

Other homologous families on the market that should be reviewed property by property (material, gauge, curvature, point family, needle and strand length, colour and CE/MDR regulatory classification) before any substitution: ETHILON® (Ethicon / J&J MedTech, black nylon monofilament), DAFILON® (B. Braun), MONOSOF™ / DERMALON™ (Medtronic / Covidien), DemeLON™ (DemeTECH), LUXAMID® (LuxSutures) and SUPRAMID® (SMI / B. Braun, polyamide pseudomonofilament). Codes from these companies for the exact configuration HS 36 of 36 mm, USP 2 and black strand of 75 cm have not been verified in public sources; they must be confirmed with the manufacturer before use in substitution or tendering.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tendering. This needle geometry (HS 36, USP 2, 75 cm) is only fully safely interchangeable within the PREMISUT system itself: the direct equivalent within the same manufacturer is the version in the Prime range of identical configuration (Ref. P642HS3602, SKU AMP642HS3602), with the same HS 36 needle, same USP gauge 2 and same black strand of 75 cm.

5. Selection tips and variants of interest

Tissue to suture: USP gauge 2 (EP 5) offers maximum strength for firm subcutaneous tissue, fascia, aponeuroses, tension skin closures, ligatures and retention sutures. The reverse cutting needle penetrates dense tissues without tearing the puncture bed. For lower tension planes, the same HS 36 family is available in USP 1 (AM642HS3601) and USP 0 (AM642HS3610) in black thread of 75 cm.

Prime quality: if the procedure requires maximum sharpness consistency lot to lot, the Prime range offers the same geometry and gauge (Ref. P642HS3602, SKU AMP642HS3602), direct equivalent within the same manufacturer.

Thread and needle length: the 75 cm cover continuous sutures or several stitches without re-threading; if greater length is needed, the HS 40 profile in USP 1 and 100 cm thread (AM647HS4001 / AMP647HS4001) can be considered, and for deeper access the HS 48 profile of 100 cm (AM647HS4801 / AMP647HS4801). For smaller fields, the HS 26 family is available (e.g. AM642HS2620 in USP 2/0).

Taper point: if the procedure requires less trauma in very distensible soft tissues, the same nylon range offers a ½ circle needle with taper point (HR 26, HR 30 and HR 37 profiles), available in SKU AM642HR2610, AM642HR3010 and AM642HR3710 in USP 0.

Sterility verification: product sterile by ethylene oxide and single-use; check the integrity of the blister and the expiry date before each use and keep the reference 642HS3602 together with the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.

Additional information

Product line

PREMISUT (standard range)

Material

Nylon monofilament (polyamide 6 or 6.6), uncoated

Structure

Monofilament with grooved surface

Coating

None

Absorption

Non-absorbable; gradual encapsulation, wound support for more than 3 months

USP size

USP 2 (metric EP 5)

Metric gauge (EP)

5

Thread diameter

0.45 – 0.499 mm

Needle shape

1/2 circle (½ circular), grooved

Tip type

Triangular reverse cutting (Reverse Cutting)

Needle size

HS 36 (36 mm)

Configuration

1 needle per unit, grooved thread

Sterilisation

Ethylene oxide (EO)

Use

Single-use, sterile. Do not re-sterilise

Presentation

Box of 12 units in individual sterile envelopes

Indications

Approximation of soft tissues, ligatures, ophthalmology and neurosurgery

Manufacturer reference

642HS3602

Regulatory standard

Complies with USP/EP Pharmacopoeia; CE marking (MDR)

Medida de aguja

HS 36

Usp

2

Color

Black

Medida de hilo

75 cm

Tipo de aguja

Reverse cutting

Forma de aguja

1/2 circle

Calidad sutura

Normal

Reviews

There are no reviews yet.

Be the first to review “NYLON Non-Absorbable Suture PREMISUT · 1/2 Circle Reverse Cutting Triangular Needle HS36 (36 mm) · USP 2 (EP 5) · Black Thread 75 cm · Polyamide Monofilament · Box of 12 units (Ref. 642HS3602)”

Your email address will not be published. Required fields are marked *