Description
Percutaneous Discectomy Device — Cervical and lumbar use · Straight and curved version · CT/Fluoroscopy guidance · CE marking · Single-use
1. Product description
The Herniatome is a percutaneous discectomy device (herniectomy) designed for minimally invasive extraction of herniated disc material. Its battery-powered motorised mechanism, lateral-window cannula and transparent collection container allow the surgeon to perform selective decompression of the intervertebral disc with real-time qualitative and quantitative assessment of the extracted material, minimising tissue trauma compared with open surgery and facilitating an outpatient procedure of less than 30 minutes.
2. Technical explanation and clinical use
- Percutaneous herniectomy is indicated for lumbar radiculopathy due to contained disc herniation, when conservative treatment (analgesics, physiotherapy, rest) has not been effective.
- The procedure is performed under computed tomography (CT) or fluoroscopy guidance, with local anaesthesia, allowing the patient to be monitored and avoiding the risks of general anaesthesia.
- The distal cannula, straight or curved, incorporates a lateral window that extends decompression coverage with minimal instrument movement.
- The transparent container allows visual inspection of the extracted material during decompression and quantification of the procedure outcome.
- Being a single-use device, the costs and risks associated with reprocessing are eliminated, ensuring consistent performance in each procedure.
- The curved version includes a 20G Break-Away type introducer needle (detachable hub) that facilitates percutaneous access and administration of local anaesthesia.
3. Technical Specifications
| Description | Percutaneous discectomy device (Herniectomy) |
| Function | Minimally invasive extraction of herniated disc material to reduce pressure on the nerve root |
| Class DM | Medical device — CE marking |
| Power supply | Battery-powered motorised device |
| Container | Transparent, for real-time qualitative and quantitative assessment of extracted material |
| Distal design | Cannula with lateral window for greater decompression coverage with minimal movement |
| Versions | Straight or curved distal end |
| Application area | Cervical spine and lumbar spine |
| Image guidance | Computed tomography (CT) and fluoroscopy |
| Anaesthesia | Local |
| Procedure duration | Less than 30 minutes |
| Distal tip | Straight or curved, with lateral window |
| Introducer needle (curved version) | 20G, Break-Away type (detachable hub) |
| Available sizes | 17G and 18G |
| Available lengths | 9 cm (cervical type) and 15 cm (lumbar type) |
| Handle | Ergonomic, designed for clinician comfort |
| Sterilisation | See individual packaging labelling |
| Presentation | Box of 1 unit |
| Use | Single-use — do not reuse |
Versions and box contents
| Version | Box contents |
|---|---|
| HERNIATOME — Straight Version | 1 Percutaneous Discectomy Device |
| HERNIATOME — Curved Version | 1 Percutaneous Discectomy Device + 1 Break-Away 20G Introducer Needle |
References and ordering information — Cervical Type
| Code | Measurements | Description |
|---|---|---|
| 5091709 | 17G x 9 cm | Curved distal end, lateral window |
| 5091749 | 17G x 9 cm | Straight distal end, lateral window |
| 5091809 | 18G x 9 cm | Curved distal end, lateral window |
| 5091849 | 18G x 9 cm | Straight distal end, lateral window |
References and ordering information — Lumbar Type
| Code | Measurements | Description |
|---|---|---|
| 5091715 | 17G x 15 cm | Curved distal end, lateral window |
| 5091745 | 17G x 15 cm | Straight distal end, lateral window |
| 5091815 | 18G x 15 cm | Curved distal end, lateral window |
| 5091845 | 18G x 15 cm | Straight distal end, lateral window |
Presentation: box of 1 unit.
4. Equivalences and Cross-References
The Herniatome is a proprietary device marketed by Cahnos, so there is no manufacturer-validated equivalence table; consult the technical department before use in tenders. Functionally, the category of single-use motorised percutaneous discectomy catheters is led on the market by the Stryker Dekompressor® system (catheter with battery-powered screw/auger-type tip, collection chamber and introducer), whose official codes appear in the manufacturer’s own surgical technique guide and are detailed below as a category comparison:
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Stryker | Dekompressor® Disk Removal System | 407-250-000 | Comparable by category (not interchangeable 1:1) | 6″ (15.2 cm) 17G straight kit; same indication for percutaneous discectomy with aspiration of disc material; includes introducer with stylet and catheter cleaner |
| Stryker | Dekompressor® Disk Removal System | 407-251-000 | Comparable by category (not interchangeable 1:1) | 6″ (15.2 cm) 17G curved kit; comparable to Herniatome 5091715 (17G x 15 cm curved); verify tip geometry and introducer |
| Stryker | Dekompressor® Disk Removal System | 407-260-000 | Comparable by category (not interchangeable 1:1) | 9″ (22.9 cm) 17G straight kit; length greater than the 15 cm lumbar variant of the Herniatome |
| Stryker | Dekompressor® Introducer Cannulas | 407-253-000 / 407-254-000 | Comparable by category (not interchangeable 1:1) | 6″ 17G straight (253) and curved (254) introducers with stylet; the curved Herniatome incorporates a 20G Break-Away needle as introducer |
Other technologies in the category of percutaneous disc decompression (such as high-pressure saline jet hydrodiscectomy systems like SpineJet® or intradiscal radiofrequency systems like Disc-FX®) share the general clinical indication but use different principles of action (saline flow and RF ablation versus motorised mechanical extraction), so they are only comparable by category and not interchangeable 1:1. The cited Stryker codes come from the manufacturer’s official surgical technique guide; the rest of the cross-references must be confirmed with the technical department.
5. Selection tips and variants of interest
- For cervical spine: select the 9 cm references (5091709, 5091749, 5091809, 5091849), suitable for the smaller thickness of the cervical disc space.
- For lumbar spine: select the 15 cm references (5091715, 5091745, 5091815, 5091845), which allow the lower lumbar discs to be reached with a safe posterolateral approach.
- 18G gauge: recommended for finer accesses and discs with lower nuclear content; 17G gauge: greater material extraction capacity.
- Curved tip: facilitates access to paramedian or foraminal hernias and lateral coverage of decompression; includes the Break-Away 20G introducer needle in the package.
- Straight tip: indicated for central approaches and for surgeons who prefer a linear access trajectory.
- Always verify the sterilisation and expiry date on the individual package labelling before use.
Regulations and documentation
| CE marking | Yes |
| Use | Single-use — do not reuse |
| Intended use | Exclusive to qualified healthcare professionals or physicians with appropriate training and experience |





Reviews
There are no reviews yet.