Description
1. Commercial Introduction
The NYLON PREMISUT Prime 1/2 Cylindrical HR50 mm Suture (Factory ref. 645HR50L10 · SKU AM645HR50L10) is the reference in the Prime range of non-absorbable sutures from Cahnos for procedures requiring a high-performance permanent suture mounted on a needle with a cylindrical body and a long taper point. It combines a nylon monofilament (polyamide 6 or 6.6), identifying black colour, USP 0 gauge and 150 cm of fluted thread in a loop presentation, on a ½ circle needle with a 50 mm taperpoint (HR50 profile). It is a common choice in ophthalmology, neurosurgery, general surgery departments and in purchasing and tendering centres that need a permanent suture with predictable clinical behaviour and full traceability. Sterile product, ready to use, presented in a box of 12 units in individual sachets.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely, gradually encapsulating and maintaining high tensile strength for more than three months, comfortably covering the critical healing phase. Being an uncoated monofilament, the thread slides easily through tissues, reduces the wicking effect and bacterial drag compared with multifilaments, and minimises the inflammatory reaction. The fluted finish of the strand improves knot retention and handling.
The 50 mm HR50 needle features a ½ circle curvature with a cylindrical body and a conical (taperpoint) point: the sharp point without cutting edges passes through tissues by separating the fibres without cutting them, making it especially suitable for soft, well-vascularised tissues (fasciae, peritoneum, muscle, conjunctiva) where minimising trauma is sought. Prime quality guarantees more consistent sharpening and more predictable penetration at every stitch. USP 0 gauge (metric EP 3.5) offers an excellent balance between tensile strength and low tissue aggression, and the 150 cm thread with loop allows continuous sutures or multiple stitches without re-threading. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament with grooved surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / USP size | USP 0 (metric EP 3.5); conforming to USP and European Pharmacopoeia gauges |
| Approximate thread diameter | 0.35 – 0.399 mm (according to USP Pharmacopoeia, non-absorbable suture) |
| Thread length | 150 cm with loop |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | 1/2 circle (½ circle) |
| Tip type | Conical / cylindrical (Taperpoint) |
| Needle size | HR 50 (50 mm) |
| Configuration | 1 needle per unit, 1 thread of 150 cm with loop |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Approximation of soft tissues, ligatures, ophthalmology and neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Storage | Below 30 °C, away from moisture and direct sunlight (according to IFU Premisut Nylon) |
| Factory reference | 645HR50L10 |
| Reference Cahnos (SKU) | AM645HR50L10 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 0 | 3.5 | 0.35 – 0.399 mm |
| 1 | 4 | 0.40 – 0.499 mm |
3.3. PREMISUT HR50 family (½ circle needle, 50 mm, conical taperpoint, black thread)
| Needle profile | USP size | Thread | Reference |
| HR50 Prime | 0 | 1 × 150 cm with loop (black) | 645HR50L10 / AM645HR50L10 (this product) |
| HR50 Prime | 0 | 1 × 150 cm with loop (black) | P645HR50L10 / AMP645HR50L10 |
| HR50 | 1 | 1 × 150 cm with loop (black) | 645HR50L01 / AM645HR50L01 |
| HR50 | 1 | 1 × 90 cm (black) | 643HR5001 / AM643HR5001 |
| HR50 Prime | 1 | 1 × 90 cm (black, Prime range) | P643HR5001 / AMP643HR5001 |
The same HR50 needle is available with a 75 cm thread (series 642) and, within the ½ circle conical needle family, in shorter profiles such as HR30 (30 mm), HR35 (35 mm) and HR40 (40 mm) for procedures with a shorter path.
4. Equivalences and Cross-References
Reference 645HR50L10 corresponds to the official nomenclature of the PREMISUT range (HR50 profile: ½ circle needle with cylindrical body and 50 mm conical taperpoint, USP 0 gauge, black 150 cm thread with loop, fluted) and Cahnos markets it without altering characters: no digit may be added, removed or reordered when ordering or tendering. Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercially of the ‘Ethilon’ type).
There is no manufacturer-validated equivalence table cross-referencing this product with other brands for the exact combination of USP 0 + ½ circle taperpoint 50 mm needle + black 150 cm loop thread; no code from another manufacturer has been verifiably found in public sources (GUDID/EUDAMED and official catalogues) that meets all the required properties within tolerance (material, gauge, curvature, point family and needle size 50 mm ±1 mm). Comparisons must be made property by property and are functional, at category level.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, USP 0, 150 cm thread with loop, CT needle with conical (taperpoint) point, ½ circle, 48 mm | W740G (confirmed in official Ethicon EMEA catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide), USP 0 gauge (EP 3.5), black colour, thread length 150 cm with loop, ½ circle curvature and conical point family; the needle size differs (CT 48 mm vs HR50 50 mm, outside the ±1 mm tolerance). Confirm needle geometry and size in the technical data sheet or IFU before any substitution. |
Homologous families that must be reviewed property by property (material, gauge, curvature, point family, needle and thread length, colour and CE/MDR regulatory classification) before any substitution: Ethicon ETHILON™ (black nylon monofilament), B. Braun Dafilon® (polyamide, black for microsurgery/ophthalmology), Medtronic Monosof™/Dermalon™ (nylon monofilament), SMI SUPRAMID, LuxSutures Luxamid and DemeTECH DemeLON. No codes from these manufacturers have been verified in public sources for the exact HR50 50 mm configuration, USP 0 and black 150 cm loop thread; they must be confirmed with the manufacturer before use in substitution or tendering.
There is no equivalence table validated by the manufacturer for this configuration; check the exact gauge, thread length, needle geometry and size, colour and regulatory classification (CE/MDR) in the technical data sheet or instructions for use of the alternative manufacturer before using this information in tenders or direct substitution. This needle geometry (HR50, USP 0, 150 cm with loop) is only interchangeable with complete safety within the PREMISUT system itself. Consult the technical department of Cahnos to validate any equivalence.
5. Selection tips and variants of interest
- Tissue to suture: the USP 0 gauge (EP 3.5) is ideal for approximation of soft and subcutaneous tissue with medium tension, providing high tensile strength with minimal tissue reaction, always with a conical point needle to avoid cutting the fibres.
- Needle length: the HR50 profile of 50 mm covers medium-depth accesses. For smaller fields, the HR30, HR35 and HR40 families from the same range are available (e.g. HR40 and HR30 in USP 0 with 150 cm looped thread, Ref. AM645HR40L10 and AM645HR30L10).
- Thread length and presentation: the 150 cm with loop are practical for ligatures, continuous sutures and deep-field surgery without re-threading. If a 90 cm thread without loop is preferred, the same HR50 needle in USP 1 is available (Ref. 643HR5001 / AM643HR5001).
- Alternative gauge: for tissues with higher tension, the same HR50 geometry in USP 1 with 150 cm loop (Ref. 645HR50L01 / AM645HR50L01), or the Prime version of this same configuration (Ref. P645HR50L10 / AMP645HR50L10) when maximum sharpness consistency from lot to lot is required.
- Sterility verification: product sterile by ethylene oxide and single-use; check the blister integrity and expiry date before each use, and keep the reference 645HR50L10 and the batch number for traceability in the operating theatre. Store below 30 °C, away from moisture and direct sunlight.
- For special B2B conditions by volume, hospital supply agreements or validation of equivalents from other commercial houses, contact the technical-commercial team of Cahnos.





Reviews
There are no reviews yet.