Description
1. Commercial Introduction
The 75 cm NYLON Suture PREMISUT Prime 4/0 Black with a ½ circle needle with triangular reverse cutting point of 17 mm (HS17 profile) is the reference in the Prime range from Cahnos for procedures requiring a permanent suture of maximum precision mounted on a short-bodied needle. It combines a nylon monofilament (polyamide 6 or 6.6) in identifying black, USP size 4/0 and 75 cm strand, with a ½ circle reverse cutting needle of 17 mm.
It is the usual choice in ophthalmology, neurosurgery and general surgery departments and in purchasing and tendering centres that need a high-performance non-absorbable suture with predictable clinical behaviour and complete batch traceability. Sterile, ready-to-use product, presented in a box of 12 units in individual sachets with batch traceability.
2. Technical Explanation
Nylon (polyamide 6 or 6.6) is a non-absorbable synthetic polymer that remains in the tissue indefinitely: it gradually becomes encapsulated by fibrous connective tissue and retains high tensile strength for more than three months, comfortably covering the critical healing phase. As an uncoated monofilament, the suture slides easily through tissues, does not produce a wicking effect, reduces bacterial drag compared with multifilament sutures and minimises the inflammatory reaction, an essential behaviour in delicate planes and cosmetic sutures.
The ½ circle needle with a 17 mm triangular reverse cutting point is the standard choice for firm, poorly distensible tissues: the cutting edge cuts in the opposite direction to the wound bed, creating a clean entry hole that preserves the skin edge and prevents the cut from widening. USP size 4/0 (metric EP 1.5) offers the optimal balance between fineness and strength for skin, subcutaneous tissue and ligatures. Sterilisation by ethylene oxide (EO); single-use product, not re-sterilisable.
3. Technical Specifications
3.1. General characteristics
| Parameter | Specification |
| Brand / Quality | PREMISUT Prime (premium range) |
| Thread material | Nylon monofilament (polyamide 6 or 6.6), uncoated |
| Thread structure | Monofilament, smooth surface |
| Absorption | Non-absorbable; gradual encapsulation, wound support for more than 3 months |
| Gauge / Size | USP 4/0 (metric EP 1.5), conforming to USP sizes and European Pharmacopoeia |
| Approximate thread diameter | 0.150 – 0.199 mm (non-absorbable synthetic suture) |
| Thread length | 75 cm (free end, without loop) |
| Thread colour | Black identifier (high visibility in surgical field) |
| Needle shape | ½ circle (1/2 circle) |
| Tip type | Triangular reverse cutting (Reverse Cutting) |
| Needle size | 17 mm (HS 17 Prime profile) |
| Configuration | 1 needle per unit, single-armed |
| Sterilisation | Ethylene oxide (EO) – sterile |
| Use | Single-use, sterile. Do not re-sterilise |
| Indications | Soft tissue approximation, ligatures, ophthalmology, neurosurgery |
| Commercial presentation | Box of 12 units (sterile individual sachets); batch traceability |
| Regulatory standard | Sizes in accordance with USP/EP Pharmacopoeia; CE marking (MDR) |
| Factory reference | P642HS1740 |
| Reference Cahnos (SKU) | AMP642HS1740 |
3.2. Gauge equivalence according to USP/EP Pharmacopoeia (synthetic non-absorbable suture)
| USP size | Metric measurement (EP) | Approximate thread diameter |
| 4/0 (this product) | 1.5 | 0.150 – 0.199 mm |
| 3/0 | 2 | 0.20 – 0.249 mm |
| 2/0 | 3 | 0.30 – 0.339 mm |
3.3. PREMISUT HS17 family (½ circle needle, 17 mm, triangular reverse cutting point, black 75 cm thread)
| Needle profile | USP size | Thread | Reference |
| HS 17 | 4/0 | 1 × 75 cm (black) | 642HS1740 / AM642HS1740 |
| HS 17 Prime | 4/0 | 1 × 75 cm (black) | P642HS1740 / AMP642HS1740 (this product) |
| HS 17 | 3/0 | 1 × 75 cm (black) | 642HS1730 / AM642HS1730 |
| HS 17 Prime | 3/0 | 1 × 75 cm (black) | P642HS1730 / AMP642HS1730 |
Reference code breakdown: P (Prime range) + 642 (black 75 cm suture) + HS17 (½ circle needle with triangular reverse cutting point of 17 mm) + 40 (USP size 4/0). The 641 series corresponds to 45 cm suture and the 643 series to 90 cm. Cahnos markets the official reference without altering characters: no digit may be added, removed or reordered when ordering or tendering.
4. Equivalences and Cross-References
Reference P642HS1740 corresponds to the official nomenclature of the PREMISUT Prime range (HS17 profile: ½ circle needle with triangular reverse cutting point of 17 mm, USP size 4/0, black 75 cm suture). Black non-absorbable nylon monofilament is one of the most standardised permanent suture families on the market (commercial type ‘Ethilon’), but there is no manufacturer-validated equivalence table cross-referencing this reference with other brands for the exact combination USP 4/0 + ½ circle reverse cutting needle of 17 mm + black 75 cm strand. The following comparison is functional, at category level, and must be confirmed against the technical data sheet or the instructions for use (IFU) of each manufacturer before use in tendering or direct substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Ethicon (J&J MedTech) | ETHILON® – black nylon monofilament, 4-0, 45 cm (18″), PS-4 needle of 16 mm, ½ circle, reverse cutting | 1662G (verified in official Ethicon catalogue and authorised distribution) | Comparable by category (not interchangeable 1:1) | They match in material (polyamide 6/6.6), size 4-0 (EP 1.5), black colour, ½ circle curvature, reverse cutting point family and needle size of 16 mm (within ±1 mm tolerance versus 17 mm); they differ in suture length (45 cm versus 75 cm) and the precision finish of the needle. Verify IFU before substituting. |
Other homologous families in the segment that must be reviewed property by property (material, gauge, half-circle curvature, reverse-cutting point family, needle length of 17 mm within ±1 mm tolerance, thread length of 75 cm, black colour, armed with 1 needle and CE/MDR regulatory classification) before any substitution: DAFILON® (B. Braun, black monofilament polyamide, intended for microsurgery and ophthalmology), MONOSOF™ and DERMALON™ (Medtronic/Covidien), DemeLON™ (DemeTECH), LUXAMID® (LuxSutures) and the polyamide ranges from Serag-Wiessner. No code has been found in public sources (GUDID/EUDAMED and official catalogues) from these manufacturers that reproduces the exact combination HS17 + USP 4/0 + black 75 cm thread, therefore no unverified third-party cross-reference codes are published. The cited trademarks belong to their respective manufacturers and are mentioned solely as an equivalence reference. This needle geometry (HS17, USP 4/0, 75 cm thread) is only safely interchangeable within the PREMISUT system itself. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Tissue to suture: USP 4/0 gauge (EP 1.5) is the reference size for skin, subcutaneous tissue and soft tissues under low-to-medium tension. The HS17 reverse-cutting needle penetrates firm, non-distensible tissues without tearing the puncture bed, being indicated in general surgery, ophthalmology, neurosurgery and ligatures; for planes under higher tension, consider the 3/0 from the same family (AMP642HS1730) or longer needle profiles.
Prime quality: this reference belongs to the Prime range, which adds maximum sharpening precision and batch-to-batch consistency compared with the standard range (ref. 642HS1740 / SKU AM642HS1740), a direct equivalent within the same manufacturer with identical needle geometry, gauge and thread length.
Surgical precision: if the protocol requires an extra-long reverse-cutting edge with a square body for plastic and cosmetic surgery, the range offers the XHS 17 Prime precision profile (ref. AMP642XHS1750, gauge 5/0 and 75 cm thread). For approaches where a cylindrical needle with a conical point is preferred, the same range offers the HR 16 version (ref. AMP642HR1640).
Presentation and sterility: this reference is supplied in a box of 12 units in individual sterile sachets with batch traceability, the usual format for operating theatres, purchasing departments and tenders. Check the blister integrity and expiry date before each use and keep reference P642HS1740 together with the batch number for traceability. Store below 30 °C, away from moisture and direct sunlight. For B2B volume conditions or hospital supply agreements, contact the technical-commercial team at Cahnos.





Reviews
There are no reviews yet.