Description
1. Commercial Introduction
Maintain the light quality required by your equipment fleet with the halogen lamp Philips 7158XHP (24V, 150W, G6.35 cap). This is a professional quartz capsule spare part without reflector, a classic reference in high demand for medical electronics illuminators, dental units, microscopes, slide projectors and clinical film viewers. A reliable solution for medical electronics technical services, hospital maintenance departments and optics workshops that need a certified replacement, with direct mounting and predictable performance, at the best price and with immediate availability.
2. Technical explanation
This lamp uses regenerative cycle halogen technology with a distortion-free quartz bulb, allowing the tungsten filament to operate at high temperatures while maintaining a stable and constant luminous flux throughout its service life. It operates at very low voltage (24V), so it must always be powered through the transformer or power supply incorporated in the original equipment. The G6.35 bipin cap ensures a firm seat and a reproducible position of the luminous centre (LCL of 33 mm), key for precise focusing in optical, projection and clinical lighting systems. Its colour temperature of 3450K and colour rendering index CRI 100 ensure distortion-free colour perception, an essential requirement in medical, dental and diagnostic applications where colour is clinical information.
3. Technical Specifications
Validated product features, retaining the original manufacturer data:
| Characteristic | Value |
| Brand / Series | Philips (reflectorless series) |
| Model | 7158XHP (ANSI FCS designation, LIF A1/216) |
| Manufacturer reference (12NC) | 924031720503 |
| EAN code | 8711500410207 |
| Technology | Halogen, quartz capsule without reflector |
| Voltage | 24V |
| Power | 150W |
| Base | G6.35 (bipin) |
| Luminous flux | 6,000 lumens |
| Colour temperature | 3450K |
| Colour rendering index (CRI) | 100 |
Dimensional and usage data:
| Parameter | Value |
| Diameter | 11.5 mm |
| Total length | 50 mm |
| Light centre length (LCL) | 33 mm |
| Maximum base temperature | 400 °C |
| Maximum bulb temperature | 900 °C |
| Approximate service life | 40-50 hours |
| Presentation | Unit |
| Applications | Medical electronics, dentistry, projection, slide projection, microscopy and film viewers |
4. Equivalences and Cross-References
The Philips 7158XHP lamp complies with the international standard ANSI FCS and the LIF designation A1/216, so it is interchangeable with spare parts of the same standard from other manufacturers, always checking voltage (24V), power (150W), cap (G6.35) and dimensions. Its direct equivalent is the OSRAM 64640 HLX (24V 150W G6.35, also 6,000 lumens), which is sold at Cahnos under reference PH3209-LM. Within the Cahnos catalogue, it is part of the family of medical electronics halogen lamps:
| Reference Cahnos | Model | Power / Voltage | Base |
| OSR3210-LM | Philips 7158XHP (current product) | 150W / 24V | G6.35 |
| PH3209-LM | OSRAM 64640 HLX (direct equivalent) | 150W / 24V | G6.35 |
| OSR3209-LM | OSRAM 64633 HLX | 150W / 15V | G6.35 |
| PH7387-LM | OSRAM 64655 HLX | 250W / 24V | G6.35 |
| PH6605LD-LM | OSRAM 64657 HLX | 250W / 24V | G6.35 |
5. Selection tips and variants of interest
Before replacing the lamp, confirm that your equipment operates at 24V and accepts a G6.35 cap, as well as the available space in the illuminator housing (11.5 mm diameter by 50 mm length). Always handle the quartz bulb with gloves or a clean, dry cloth: fingerprints or grease on the quartz drastically reduce the lamp’s service life. Perform the replacement with the equipment switched off and cold, and do not exceed the nominal voltage of 24V. If your application requires greater luminous flux while keeping the same cap, you have the 250W 24V range (ref. PH7387-LM, 10,000 lumens, or ref. PH6605LD-LM, 9,000 lumens and 300 hours of life). For 15V equipment, consult the OSRAM 64633 HLX 15V 150W (ref. OSR3209-LM), also with G6.35 cap. Our technical-commercial team is at your disposal to advise you on identifying the exact replacement for your equipment fleet.