Keep the light quality required by your equipment fleet with the halogen lamp Philips 7023 (designation FCR A1/215), a professional quartz capsule spare part without reflector designed for medical electronics illuminators, dental units, microscopes, viewers and 8 mm and Super 8 projectors. It is a reliable solution for medical electronics technical services, hospital maintenance departments and optical workshops that need a certified replacement, direct mounting and predictable performance, at the best price and with immediate availability.
2. Technical Explanation
This lamp uses regenerative cycle halogen technology with a quartz bulb without reflector, allowing the tungsten filament to work at high temperature while maintaining a stable and constant luminous flux throughout its service life. It operates at very low voltage (12V) with a power consumption of 100W, so it must always be powered through the transformer or power supply incorporated in the original equipment. The bipin base GY6.35 guarantees a firm seat and a reproducible position of the luminous centre (LCL of 30 mm), key to precise focusing in optical, projection and clinical lighting systems. Its colour temperature of 3450K and its colour rendering index CRI 100 ensure distortion-free colour perception, an indispensable requirement in medical, dental and diagnostic applications where colour is clinical information. Furthermore, it is dimmable, allowing the light intensity to be adjusted according to the procedure.
3. Technical Specifications
Validated product features, retaining the original manufacturer data:
| Characteristic | Specification |
|---|---|
| Brand / Model | Philips 7023 (enables FCR, LIF A1/215) |
| Manufacturer reference (EAN) | 8711500409812 (12NC 923870017103) |
| Technology | Halogen without reflector, quartz bulb |
| Voltage and power | 12V; 100W |
| Base | GY6.35 (bipin, two pins) |
| Luminous flux | 3600 lumens |
| Colour temperature | 3450K |
| Colour rendering index | CRI 100 |
| Regulation | Yes (dimmable) |
| Applications | Medical electronics, medical and dental use, microscopy, 8 mm projection, Super 8 |
| Presentation | Unit |
| Reference Cahnos | OSR3208-LM |
Dimensional and usage data:
| Parameter | Value |
|---|---|
| Diameter | 11.5 mm |
| Total length | 44 mm |
| Luminous area | 4.2 × 2.3 mm |
| Light centre length (LCL) | 30 mm |
| Maximum base temperature | 400 °C |
| Maximum bulb temperature | 900 °C |
| Shelf life | 50 hours |
4. Equivalences and Cross-References
The Philips 7023 lamp complies with the standardized designation ANSI FCR and LIF A1/215 (NAED code 54248), so it is interchangeable with spare parts of the same standard from other manufacturers, always verifying voltage (12V), power (100W), base (GY6.35) and dimensions. Its direct equivalent is the OSRAM 64625 HLX Xenophot (also 12V 100W GY6.35, 3600 lumens), as well as the GE FCR references, Ushio 1000490, Narva 55301 / 682.92 and the generic nomenclature JC12V-100W. Within the Cahnos catalogue, it is part of the family of low-voltage medical electronics halogen lamps together with the Philips 7158XHP 24V 150W (ref. OSR3210-LM), the OSRAM 64633 HLX 15V 150W (ref. OSR3209-LM) and the OSRAM 64627 HLX 100W 12V with reflector (ref. PH12100-LM).
| Reference | Model | Power / Voltage | Base |
|---|---|---|---|
| OSR3208-LM | Philips 7023 (current product) | 100W / 12V | GY6.35 |
| PH12100-LM | OSRAM 64627 HLX (with reflector) | 100W / 12V | GZ6.35 |
| OSR15150-LM | Philips 6834FO (with reflector) | 100W / 12V | GZ6.35 |
| AL223-LM | Electrical 100W 12V (prefocal) | 100W / 12V | GZ9.5 |
| OSR3210-LM | Philips 7158XHP | 150W / 24V | G6.35 |
5. Selection tips and variants of interest
Before replacing the lamp, confirm that your equipment operates at 12V and accepts a GY6.35 base, as well as the available space in the illuminator housing (11.5 mm diameter by 44 mm length) and the luminous centre height of 30 mm. Always handle the quartz bulb with gloves or a clean, dry cloth: fingerprints or grease on the glass drastically reduce the lamp’s service life. Perform the replacement with the equipment switched off and cold, and do not exceed the nominal voltage of 12V. If your equipment accepts another mounting base, you have the version with MR16 dichroic reflector of 100W 12V (ref. PH12100-LM or OSR15150-LM); for 24V equipment, consult the OSRAM 64640 HLX (ref. PH3209-LM) or the Philips 7158XHP (ref. OSR3210-LM). For maintenance orders or large volumes, our technical-commercial team can advise you on identifying the exact spare part for your equipment fleet.