We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Halogen-Free Incandescent Lamp ELECTRICAL 12V 50W BA20D Base for Projection and Medical Electronics

12,32 €

Medical electronics lamp ELECTRICAL 12V and 50W with BA20D base, manufactured in halogen-free incandescence and designed for projection, optics, photometry and clinical use. It emits 1200 lumens with a duration of 50 hours and compact dimensions of 35 mm diameter and 69 mm length (LCL 39.5 mm), key for precision optical adjustment in medical electronics equipment. Professional spare part for direct mounting, compatible with cinema lamps, projectors and laboratory optical systems. Sold per unit.

International shipping. Import duties and taxes are payable by the recipient.

Reference
PHA1261-LM

Description

1. Introduction

Maintain the light quality required by your medical electronics equipment with the incandescent lamp ELECTRICAL 12V and 50W with BA20D base. This is a professional spare part from the halogen-free series, designed for projection, optics, photometry and medical applications that require stable, reproducible light free from halogen components. A reliable solution for medical electronics services and maintenance departments looking for certified spare parts, direct mounting and predictable performance across their equipment fleet.

2. Technical explanation of the equipment

This lamp uses low-voltage incandescent technology halogen-free, which differentiates it from conventional halogen lamps and makes it especially suitable for sensitive optical equipment or specifications that require their absence. It operates at low voltage (12V) with a power consumption of 50W, so it must always be used with the equipment’s own transformer or power supply. The BA20D base (two pins with bayonet fixing) guarantees a firm seat and a reproducible position of the light centre within the illuminator, avoiding misalignment and ensuring beam stability during projections and scans. With a light centre height (LCL) of 39.5 mm, it offers precise focusing in optical systems that depend on rigorous light alignment.

3. Technical Specifications

Validated product features, retaining the original manufacturer data:

Brand ELECTRICAL
Technology Halogen-free incandescence
Voltage and power 12V 50W
Base BA20D
Luminous flux 1200 lumens
Duration 50 hours
Diameter 35 mm
Length 69 mm
Light centre height (LCL) 39.5 mm
Presentation Unit
SKU Cahnos PHA1261-LM

Applications: projection, cinema lamps, optics, photometry and medical use. Its compact design (35 mm diameter and 69 mm length) adapts to precision optical and projection systems, complying with the international BA20D base standard used in projectors and specialised luminaires.

4. Equivalences and Cross-References

Due to its construction characteristics (12V, 50W and BA20D base), this lamp complies with the international standard for incandescent lamps with BA20D bayonet base used in projection and medical optics, and is interchangeable with spare parts of the same standard from manufacturers such as Osram, Philips, Narva or Raycolt. Always check the base type, the equipment supply voltage and the bulb dimensions before replacement. Within the Cahnos catalogue, it is part of the medical electronics lamp family; if your equipment operates at 12V but requires another fixing base, halogen variants are available in 12V 50W with G6.35 base and ghiera (ref. P093926047E-LM) and with P44S base (ref. Y22815022-LM).

5. Selection tips and variants of interest

Before replacing the lamp, confirm that your equipment operates at 12V and accepts a BA20D base, as well as the available space in the illuminator housing (35 mm diameter and 69 mm length). Always handle the bulb with gloves or a clean, dry cloth: fingerprints or grease on the glass drastically reduce the lamp’s service life. Perform the replacement with the equipment switched off and cold, and do not exceed the nominal voltage of 12V. If your equipment requires another fixing base, consult the halogen variants of 12V 50W with G6.35 base (ref. P093926047E-LM) or P44S (ref. Y22815022-LM); if you need higher power, the ELECTRICAL lamp is available in 12V 100W with GZ9.5 base (ref. AL223-LM) or the surgical version of 20V 180W GZ9.5 (ref. RTBL2-LM). For maintenance orders or large volumes, our technical-commercial team can advise you on identifying the exact spare part for your equipment fleet.

Additional information

Technology

Halogen-free incandescence

Voltage

12V

Power

50W

Base

BA20D

Luminous flux

1200 lumens

Duration

50 hours

LCL light centre height

39.5 mm

Application

Projection, optics, photometry and medical use

Diametro mm

35 mm

Longitud

6.9 cm

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Halogen-Free Incandescent Lamp ELECTRICAL 12V 50W BA20D Base for Projection and Medical Electronics”

Your email address will not be published. Required fields are marked *