Description
1. Echocardiography couch with electric elevation: comfort and precision in the cardiology consulting room
The echocardiography couches AGA with electric elevation (SKU AGA-H-EKA-E) are the ideal solution for cardiology consulting rooms, non-invasive diagnostic units and echocardiography rooms that need to position the patient quickly, comfortably and with total stability during the examination. Compared with manual and hydraulic versions, the electromotive drive allows the height (650–850 mm) to be adjusted effortlessly, adapting the working surface to each professional and each procedure.
Available in two frame finishes (lacquered or chrome-plated) and two tabletop widths (650 and 800 mm), these couches come as standard with a specific cut-out for the echocardiography transducer, which facilitates access of the ultrasound scanner to the patient’s thorax and side during cardiac studies. It is the reference choice for departments seeking German manufacturing quality, high load capacity and ergonomics for healthcare staff.
2. Technical explanation: why choose an echo couch with an electric motor
Echocardiographic examination requires the patient to remain in the lateral decubitus or supine position while the transducer rests on the acoustic window. The opening made in the upholstered tabletop allows the transducer to be inserted from the patient’s lower area, improving the specialist’s working angle and image quality without forcing postures.
The electric motor of these couches is maintenance-free and sealed (IPX4 protection), controlled by hand control or pedal (the latter at no extra cost). The system incorporates double-press safety lock and raises or lowers the tabletop at a speed of 11 mm/s even with patients up to 200 kg. The guide is carried out with precision double right-angle profiles that prevent swaying and lateral displacement of the tabletop, while the reinforcement plates at the corners of the frame and the chrome-plated crossbars with levelling feet provide outstanding structural stability. The headrest is continuously adjustable up to +40° and is fixed by means of a handle with a locking rod mechanism.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Length | 1900 mm |
| Head section / main board | 500 / 1400 mm |
| Height adjustment | 650 – 850 mm (electric motor) |
| Upholstery sections | 3 sections |
| Upholstery thickness | 64 mm |
| Head section adjustment | +40° (locking rods) |
| Maximum load | 200 kg |
Electric motor data: 230 V, 50/60 Hz, 3.7 A, 850 W, IPX4 protection, speed 11 mm/s, force 10,000 N, with push-button lock deactivated by double pressing. Proximity to a power outlet (ideally floor-mounted) next to the couch is recommended.
Available references
| Reference AGA | Frame | Width | Echocardiography opening |
|---|---|---|---|
| H-EKA 1065/E | Lacquered | 650 mm | 315 x 250 mm (L x W) |
| H-EKA 2065/E | Chrome-plated | 650 mm | 315 x 250 mm (L x W) |
| H-EKA 1080/E | Lacquered | 800 mm | 405 x 300 mm (L x W) |
| H-EKA 2080/E | Chrome-plated | 800 mm | 405 x 300 mm (L x W) |
Standard version: removable (sliding) upholstered insert to close the echocardiography opening and levelling feet on chrome-plated crossbars. The lifting mechanism is supplied only in lacquered finish and the crossbars with levelling feet in chrome-plated finish.
Accessories and available options
| Reference | Item | Detail | Type |
|---|---|---|---|
| EKA-AA | Folding upholstered insert | Instead of the removable version, it remains permanently connected to the couch; only possible on couches 800 mm wide. Retrofit not possible. | Factory option |
| GS-1710 | Facial opening in the head section | On the head section, oval, dimensions approx. 205 x 105 mm (L x W). Retrofit not possible. | Factory option |
| EfGS | Upholstery insert | To close the facial opening, oval, dimensions approx. 200 x 100 mm (L x W); see upholstery colours. | Factory option |
| KVG | Head section adjustment | By means of a gas spring (instead of the locking rod mechanism), operable with one hand, release button located directly on the headrest cushion. Retrofit not possible. | Factory option |
| LR-75 | Wheel set | Wheels Ø 75 mm — four swivel castors, two of them fully lockable. | Accessory |
| LR-125 | Wheel set | Wheels Ø 125 mm — four swivel castors, two of them fully lockable. | Accessory |
| LR/Z-125 | Central locking castor system | Twin swivel castors Ø 125 mm — mobility via centralised locking system, the four castors connected to each other by rods, pedals arranged diagonally at head and foot, with colour marking (green = ready to move, red = locked). Retrofit not possible. | Factory option |
| P-2065/A | Paper roll holder | For 650 mm width — chrome-plated, consisting of two fixing kits, two brackets, two clamps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
| P-2080/A | Paper roll holder | For 800 mm width — chrome-plated, consisting of two fixing kits, two brackets, two clamps and a roll holder bar (length 615 / 795 mm, Ø 20 x 1 mm), for mounting on the upholstery frame. | Accessory |
4. Equivalences and Cross-References
The four AGA references in this family (H-EKA 1065/E, H-EKA 2065/E, H-EKA 1080/E and H-EKA 2080/E) are variants from the same manufacturer (AGA Sanitätsartikel, Germany) that differ only in frame finish and width; any reference in the series can be considered a direct equivalent within the brand itself if the required width matches. The version with scissor mechanism (H-EKA …/E 965, travel 535–965 mm) is the variant with the greatest travel within the same family.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| MPI – Medical Positioning (USA) | EchoBed® X examination table – Echo Table | EchoBed® X | Comparable by category (not interchangeable 1:1) | Echocardiography table with transducer access and design oriented to specialist ergonomics. Verify electric height adjustment, opening dimensions (315×250 or 405×300 mm), maximum load and material before replacement. Verified in the manufacturer’s catalogue (MedicalExpo). |
| Mirion (USA) | Echo Pro™ Echocardiography Table | Echo Pro™ | Comparable by category (not interchangeable 1:1) | Open chassis with folding cardiac examination cushion allowing transducer access from both sides. Check the electric height range, maximum load and tabletop dimensions against the AGA H-EKA. Verified on Mirion’s official website. |
| Oakworks Medical (USA) | Ultrasound/echocardiography table series | 65258-Txx (series) | Comparable by category (not interchangeable 1:1) | Ultrasound table with cut-out for transducer and positioning accessories. Series code published by the manufacturer; confirm the specific reference, electric travel and maximum load before use in tenders. |
There is no equivalence table validated by the manufacturer that cross-references the AGA H-EKA reference with third-party codes on a 1:1 basis; for any substitution in tenders or competitions, it is recommended to verify field by field (tabletop length and width, height range, opening dimensions, maximum load and included accessories) and consult the technical department before use in tenders.
5. Selection tips and variants of interest
- Tabletop width: the 650 mm version (H-EKA 1065/E or H-EKA 2065/E) is ideal for practices with limited space; the 800 mm version (H-EKA 1080/E or H-EKA 2080/E) offers a larger support surface and a wider echocardiography opening (405×300 mm), recommended for larger patients or prolonged examinations.
- Frame finish: the chrome finish (20xx series) offers greater resistance to impacts and external agents; the lacquered finish (10xx series) is the more economical option while maintaining the same stability.
- Need for greater travel: if you need to lower the stretcher to wheelchair height (535 mm) or adapt to lower surfaces, select the electric scissor variant H-EKA …/E 965 from the same family.
- Mobility: the stretcher is supplied with fixed levelling feet; if you need to move it around the practice, request the wheel set LR-75 or LR-125, or the centralised braking system LR/Z-125 (factory option, not retrofittable).
- Additional equipment: paper roll holder P-2065/A (650 mm) or P-2080/A (800 mm), facial opening GS-1710 with EfGS insert, or headrest adjustment via KVG gas spring for one-handed operation. These factory options must be decided at the time of purchase.
- Electrical installation: provide a power outlet (ideally floor-mounted) near the stretcher; the motor operates at 230 V and the control can be by hand control or foot pedal, both included according to preference.
For special configurations, upholstery colours, tender documents or volume quotations, our technical-commercial team is at your disposal.

















Reviews
There are no reviews yet.