Description
1. Product Presentation
The Disposable Wound Retractor Ring Size L (180/190-180/220), reference WZIPS-AL-180-220, is a single-use incision protector-retractor designed to keep the wound open, widen the surgical field and protect the operative site throughout the procedure. It advantageously replaces metal retractors: it distributes tension evenly around the entire incision contour, without aggressive traction or localised pressure points. It is the reference option for wide incision access in endoscopic surgery, assisted laparoscopy and assisted open surgery, highly valued in general surgery, digestive surgery, abdominal surgery and obstetrics and gynaecology departments, with particular indication in the prevention of surgical site infection (SSI) and secondary endometriosis after caesarean section. Immediate availability and B2B price per unit.
2. What it is and how it works
The device comprises three functional elements: the outer ring, which remains outside the incision and acts as a stop on the skin, distributing retraction evenly; the insertion ring (green), which is introduced into the cavity and expands inside; and the channel or tunnel, which passes through the abdominal wall, lines the incision edges and connects both rings. Once in place, the insertion ring expands internally and the outer ring folds outward, opening the incision 360° with tension distributed around the entire contour without damaging the tissues.
- Opens the incision and expands the surgical field without the need for continuous manual traction.
- Maintains moisture and temperature in the wound bed, promoting healing.
- Reduces bleeding from the incised edge through uniform containment and prevents exogenous contamination of the wound.
- Protects tissue against accidental burns from electrodes and electric scalpel, and against tumour seeding or implantation in the incision.
- Allows the introduction of curved instruments and the extraction of bulky specimens through the channel.
3. Technical Specifications
This unit corresponds to size L of the family, with factory dimensional code 180/190-180/220 (tunnel 180 mm / inner ring 190 mm – outer ring 180 mm / length 220 mm) and dimensional tolerance of ±8.0 mm.
| Parameter | Value |
| Reference (SKU) | WZIPS-AL-180-220 |
| Factory dimensional code | 180/190-180/220 |
| Size | L |
| Inner ring diameter (D1) | 190 mm |
| Tunnel / channel diameter (D2) | 180 mm |
| Outer ring diameter (D3) | 180 mm |
| Tunnel length | 220 mm |
| Dimensional tolerance | ± 8.0 mm |
| Models / materials | Model A: IPS-1 series (polymers); Model B: IPS-B series (silicone) |
| Use | Single-use (disposable) |
| Presentation | Unit |
Materials of the available series:
| Series / Model | Material | Configuration |
| IPS-1 (Model A) | Medical-grade polymers | Variable tunnel length: adapts to different abdominal wall thicknesses |
| IPS-B (Model B) | Medical-grade silicone | Fixed length: stable geometry for defined incisions |
Size family and series references (factory codes):
| Size / Model | Dimensional code | Inner ring D1 (mm) | Tunnel D2 (mm) | Outer ring D3 (mm) | Tunnel length (mm) |
| WZIPS-A (S) | 50/50-50/220 | 50 | 50 | 50 | 220 |
| WZIPS-A (S) | 60/70-60/220 | 70 | 60 | 60 | 220 |
| WZIPS-A (S) | 60/70-60/150 | 70 | 60 | 60 | 150 |
| WZIPS-A (S) | 80/90-80/150 | 90 | 80 | 80 | 150 |
| WZIPS-A (M) | 120/130-120/220 | 130 | 120 | 120 | 220 |
| WZIPS-A (M·L) | 150/160-150/220 | 160 | 150 | 150 | 220 |
| WZIPS-A (L) – this product | 180/190-180/220 | 190 | 180 | 180 | 220 |
| WZIPS-A (XL) | 220/230-220/250 | 230 | 220 | 220 | 250 |
| WZIPS-A (XL) | 250/260-250/100 | 260 | 250 | 250 | 100 |
4. Equivalences and Cross-References
The SKU WZIPS-AL-180-220 is a catalogue code of Cahnos (WZIPS family, IPS-1 polymer series or IPS-B silicone series depending on the model). The dimensional code 180/190-180/220 follows the factory nomenclature D1 (inner ring) / D2 (tunnel) / D3 (outer ring) / tunnel length, in millimetres, shared by several manufacturers of incision protectors-retractors. There is no manufacturer-validated equivalence table cross-referencing this reference 1:1 with other manufacturers; the matches shown below are functional comparisons verified against public sources and sector catalogues, and must be confirmed with the technical department before use in tendering.
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
| Applied Medical (USA) | Alexis O (incision protector-retractor, medium-large range) | Alexis series, intermediate and large sizes (according to the manufacturer’s official tables) | Comparable by category (not interchangeable 1:1) | Same 360° retraction principle and surgical site protection; polyurethane sheath, rigid or flexible outer ring and sizing by incision length. Verify material, dimensions and registration before substituting. |
| Grena Ltd. (United Kingdom) | RingProtect™ Disposable Wound Protector/Retractor | Dimensional coding by size (e.g. verified for size S: 0221-060070150) | Comparable by category | Medical-grade silicone and adjustable height; European distribution. Confirm the specific reference for size L in the manufacturer’s official catalogue before use. |
| Another manufacturer | WQA / WQB series | Equivalent dimensional coding by size | Comparable by category | Polyurethane rings; silicone pin (fixed height, WQB series) or polyurethane pin (variable height, WQA series). |
| Another manufacturer | Incision protector-retractor, CSQA series | Equivalent dimensional coding by size | Comparable by category | Variable length series; medical-grade polymer; check the incision range of the equivalent size. |
| CITEC Group | Disposable incision protector | CITEC series by size (verified for small sizes: CIT-QKB) | Comparable by category | Silicone series; presentations in multi-unit packaging; verify dimensions of size L. |
| Asian series such as QYK-II / PQB | Large-format incision protectors-retractors | References such as 180/190-250/260 in distribution channels | Not verified / pending confirmation | Found on marketplaces and distribution channels; not verified against the manufacturer’s official datasheet. Confirm before use in tendering. |
Note: the literal match of the dimensional code between manufacturers does not imply automatic clinical interchangeability: before substituting one reference for another, the material, height (fixed or variable), actual diameters and regulatory classification of each product must be checked. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before use in tendering or hospital substitution process.
5. Selection tips and variants of interest
Size selection: size L (180/190-180/220) is the recommended option for wide incisions in endoscopic surgery, assisted laparoscopy and large access sites, including the removal of bulky specimens. For smaller incisions, consider sizes M (120/130-120/220) and M·L (150/160-150/220); for large-format access, size XL (220/230-220/250) from the same family.
Model A vs. Model B: model A (IPS-1 series, polymers) offers variable tunnel length and is preferable when abdominal wall thickness requires adjusting the height; model B (IPS-B series, silicone) provides maximum flexibility and stable geometry for defined incisions. If a low profile is required, refer to the WZIPS-BS silicone references.
Canal compatibility: verify that the tunnel diameter (180 mm) accommodates curved instruments or the specimen to be removed in single-incision or assisted procedures.
Single-use: do not re-sterilise; respect the expiry date and storage conditions of the sterile packaging.
Accessories: combine with disposable trocars and the rest of the laparoscopic equipment in the catalogue to complete the surgical field.
For quotations, specifications and tenders, contact the technical department at Cahnos for validation of the reference and its equivalents.








Reviews