Description
Thermal paper block for cardiotocographs Wakeling Medical FM 60 / IM 88
The Wakeling Medical thermal paper pad, model FM 60 / IM 88, is the recording consumable that keeps the Wakeling Medical cardiotocograph family operational in obstetric clinics, delivery rooms and maternal-fetal monitoring units. Its folded format of 120×100 mm with 150 sheets and red grid ensures a clear, stable and perfectly measurable recording of fetal heart rate (FHR) and uterine activity (UA) at each attendance. A reliable paper supply ensures continuity of care and correct clinical documentation for each patient, supplied in a box of 20 units, reference 0553173-WM.
Technical product explanation
This pad uses direct thermal printing technology: the cardiotocograph’s thermal head transfers heat to the paper’s thermosensitive layer and produces the trace without the need for ink, toner or ribbon, which reduces equipment maintenance and allows the recording to be obtained immediately after each test. The pre-printed red grid acts as a millimetric reference on the paper itself: it allows the heart rate scale (bpm), uterine dynamics and recording speed to be assessed, facilitating clinical interpretation of the cardiotocogram. The folded pad format (z-fold) is placed directly in the equipment tray, avoiding cuts and handling during continuous monitoring. The highly sensitive thermosensitive layer offers a friction-resistant trace, ideal for preservation and filing in the clinical record.
Technical specifications
| Characteristic | Detail |
| Brand | Wakeling Medical |
| Model / compatible equipment | FM 60 / IM 88 |
| Reference Cahnos (SKU) | 0553173-WM |
| OEM / manufacturer reference | 9088-0005 (stated on supply label) |
| Internal code | 7868 |
| Block dimensions | 120 mm × 100 mm (folded sheet) |
| Contents | 150 sheets per block (Z-fold / z-fold format) |
| Grid colour | Red |
| Paper type | High-sensitivity thermal paper |
| Printing system | Direct thermal by printhead (no ink or toner) |
| Application | Cardiotocography (CTG): fetal recording and maternal-fetal monitoring |
| Presentation | Box of 20 units |
| Classification | Class I medical device (with measuring function) · CE marking |
| Storage | Cool, dry place (5–40 °C), away from direct sunlight and excessive humidity |
| Trace shelf life | 5 years after printing (follow product instructions) |
Note: the designation ‘150 mts’ in the original commercial data sheet corresponds to 150 folded sheets of 120×100 mm, as confirmed by the sector’s technical data sheets. The OEM code 9088-0005 could not be verified in public regulatory databases (GUDID/EUDAMED); confirm with the manufacturer before use in tenders.
Equivalences and cross-references
The 120×100 mm × 150-sheet format with red grid is an international standard in CTG recording for fetal monitoring. The alternatives listed below share the same format and have been verified in manufacturer and authorised distributor catalogues; before replacing, always check the grid colour, number of sheets and paper weight against your monitor’s manual.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Kranzbühler | CTG paper FetaControl / FetaSave 2-10 · AM 66 (OEM 3002-016) | EKG 3002016 | Comparable by category (not interchangeable 1:1) | Same format 120×100 mm × 150 sheets and same OEM reference 3002-016; confirm grid colour and paper weight against the original pad. Confirmed on the manufacturer’s website (GTIN 4250123603299). |
| TecnoCarta (authorised distributor) | Thermal fanfold 120×100×150sh for Wakeling Med. IM 88 | ZM44120015100KN | Comparable by category (not interchangeable 1:1) | Same format 120×100 mm × 150 sheets and same equipment family (IM 88); confirm grid colour and presentation before replacement. Confirmed in the distributor’s official online catalogue. |
| TecnoCarta (authorised distributor) | Thermal fanfold 120×100×150sh for Kranzbühler FETASAFE / Kontron AMS 66 (OEM 3002-016) | ZM37120015100KN | Comparable by category (not interchangeable 1:1) | Same format and same OEM reference 3002-016; verify red grid and paper weight against the original pad. Confirmed in the distributor’s official online catalogue. |
| Medizintechnik Patz (specialised distributor) | CTG-Papier for Kranzbühler FetaControl / FetaSave 2-10, 150 sheets 120×100 | E1017 | Comparable by category (not interchangeable 1:1) | Same OEM reference 3002-016 and same format; confirm pad presentation and red grid. Source: distributor’s online store. |
| First Medical Shop (specialised distributor) | CTG Faltbücher Kranzbühler 3002-016 for FetaControl / FetaSave 2-10 | FM0003551 | Comparable by category (not interchangeable 1:1) | Same original reference 3002-016 and 150 sheets per pad; supplied in a pack of 10 pads versus Cahnos’s box of 20; verify presentation and fit in the equipment. |
Within the same format family, pads that differ in width, number of sheets or grid colour are not 1:1 interchangeable: e.g. Kranzbühler 3002-007 (95×100×500 sheets, green), 3002-015 (142×100×400 sheets, green) and 3002-025 (150×100×150 sheets, red), as well as the Wakeling AFM 210 formats (100×100×150 sheets, blue, OEM 9210-0006) and 9260-0005 (144×100×150 sheets). Always consult the monitor manual before using any reference as a replacement. There is no manufacturer-validated equivalence table; consult the technical department before use in tenders.
Selection tips and variants of interest
Verify the format before replacing: the three parameters that define this consumable are the 120 mm width, the 100 mm sheet length and the red grid. A different format (e.g. 100×100, 144×100 or 150×100 mm) will not fit in the equipment compartment and will cause misaligned or illegible recordings. Confirm in the manual that your cardiotocograph prints via a thermal head and that the grid colour is the one indicated in your protocol: versions with a blue grid or other colours are not interchangeable without prior verification. In the Cahnos catalogue you will find variants of the same fetal recording family: the 120×100×150-sheet pad with red grid for the Advanced M. Systems FHR 240 / IM 76 / IM 88 / AM 56 families (ref. 0992808) and Kranzbühler AM 66 / FetaControl (ref. 0553173-KB), the 100×100×150-sheet pad for Wakeling AFM 210 (ref. 0992006) and other CTG formats of 150×100 and 152×90 mm. Store the pads in a cool, dry place (5–40 °C), away from direct sunlight and heat sources, to preserve the paper’s thermal sensitivity and prevent fogging of the thermosensitive layer; correct storage guarantees the sharpness and durability of the trace in the clinical record throughout its 5-year service life. For hospitals and maintenance contracts we can schedule periodic deliveries; request a formal quotation from our technical-commercial team.