We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

TITANOX 60 l electronic forced-air warmer for physiological solutions and instrument drying (Ref. 35555)

1.615,00 €

TITANOX electronic forced-air warmer with 60 l capacity, designed to warm physiological solutions in their original containers before use and to function as a drying chamber for washed surgical instruments. Housing and internal structure in stainless steel with 3 shelves, door with tempered glass and lock, fibreglass insulation and continuously operating fan that ensures a uniform temperature throughout the chamber. C.P.S. electronic control with continuous (standby) and timed modes, adjustable temperature range from 30 °C to 70 °C (preset to 37 °C) and safety thermostat included. Compliant with Regulation MDR 2017/745 and manufactured in Italy. Ideal for emergency departments, operating theatres and intensive care units.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35555

Description

1. Introduction

The TITANOX electronic forced-air heater, in its 60-litre version, is the professional solution for keeping physiological solutions at the appropriate temperature before administration and for drying previously washed surgical instruments. Thanks to its fully stainless steel construction and forced ventilation system, it offers homogeneous and reliable heat distribution, designed for daily use in hospitals, clinics and emergency and intensive care services. At Cahnos we make it available to you with technical-commercial advice for equipment, institutional purchases and tenders.

2. Technical explanation of the equipment

The 60 l TITANOX is a forced-air hot air unit: a stainless steel sheathed heating element heats the chamber while a wired fan remains in continuous operation during both the heating and cooling cycles, thus ensuring a uniform temperature throughout the entire internal volume. The internal structure, including the three shelves, the door and the inner door panel, is made of stainless steel; the door incorporates toughened glass that allows visual monitoring of the load and a non-toxic silicone rubber gasket, while insulation is provided by fibreglass.

The unit incorporates adjustable ventilation tunnels located on the lower right side and the upper left side, which facilitate the release of moisture, making it especially suitable as a drying chamber for washed surgical instruments. Operation is electronic with a C.P.S. system, with selectable continuous (standby) or timed modes, and includes a safety thermostat. In the event of a power supply interruption, the unit indicates this automatically and the programme restarts from the beginning. The device complies with Regulation MDR 2017/745 and is manufactured in Italy.

3. Technical Specifications

Technical specifications

Parameter Specification
Capacity 60 l
Temperature range Adjustable from 30 °C to 70 °C (preset to 37 °C)
Timer Adjustable from 0 to 250 minutes
External dimensions 705 x 450 x h 475 mm
Internal dimensions 535 x 320 x h 345 mm
Voltage 230 V – 50/60 Hz

Product data

Parameter Value
Manufacturer GIMA
Factory reference 35555
Sales unit 1 unit
Device type Medical device
Device class I
CND Z12019099
Material Stainless steel (casing, internal structure, 3 shelves, door and inner panel); toughened glass in the door; non-toxic silicone rubber gasket; fibreglass insulation; stainless steel sheathed heating element
Number of shelves 3 internal shelves
Closure Door with lock
Ventilation Adjustable ventilation tunnels (lower right and upper left); continuous-operation fan
Control Electronic C.P.S. with continuous (standby) and timed modes
Safety Safety thermostat; automatic indication of power supply problems and programme restart after power failure
Regulatory standard MDR 2017/745
Origin Made in Italy

4. Equivalences and Cross-References

There is no manufacturer-validated equivalence table cross-referencing this equipment with other brands; market alternatives must be compared at category level and verified field by field (voltage, temperature range, chamber dimensions, type of ventilation and MDR/CE certification) before any substitution.

Within the TITANOX family itself, reference 35555 (60 l electronic forced-air heater) shares capacity and external and internal dimensions (705 x 450 x h 475 mm / 535 x 320 x h 345 mm) with the 60 l TITANOX hot-air fan-assisted steriliser (ref. 35584), although the latter is intended for dry heat sterilisation cycles. For budgets and tenders, the technical-commercial department of Cahnos can provide you with a detailed comparison with the reference your centre currently uses.

5. Selection tips and variants of interest

  • Capacity: the 60 l format is suitable for emergency services, operating theatres and intensive care units with a medium workload; for larger loads, consider the higher-capacity TITANOX series.
  • Dual use: in addition to heating physiological solutions in their original containers, the unit functions as a drying chamber for washed surgical instruments; plan the load according to the temperature and time programmed for each application.
  • Operating modes: use the continuous (standby) mode with the 37 °C preset to have solutions ready immediately, and the timed mode (0-250 minutes) for programmed drying or heating cycles.
  • Electrical safety: verify that the mains voltage (230 V – 50/60 Hz) matches the equipment label; the safety thermostat protects against overheating and the automatic programme restart preserves cycle traceability in the event of a power failure.
  • Maintenance: clean the stainless steel surfaces and toughened glass with non-abrasive hospital-grade products; periodically check the condition of the silicone rubber gasket and the ventilation tunnels.
  • For institutional purchases, supply lead times or tender requirements, consult your technical-commercial advisor at Cahnos.

Additional information

Manufacturer reference

35555

Heating type

Electronic forced air with forced ventilation

Temperature range

30 °C to 70 °C (preset 37 °C)

Timer

0 to 250 minutes

Dimensions

705 x 450 x h 475 mm

Internal dimensions

535 x 320 x h 345 mm

Material

Stainless steel; toughened glass; non-toxic silicone rubber gasket; fibreglass

Number of shelves

3

Control

Electronic C.P.S., continuous (standby) and timed modes

Safety

Safety thermostat; automatic programme restart after power failure

Door closure

Key lock

Ventilation

Adjustable ventilation tunnels and continuous-operation fan

CND code

Z12019099

Regulatory standard

MDR 2017/745

Origin

Made in Italy

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

I

Capacidad

60 L

Alimentacion

Mains power

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF

Reviews

There are no reviews yet.

Be the first to review “TITANOX 60 l electronic forced-air warmer for physiological solutions and instrument drying (Ref. 35555)”