Oral Endotracheal Tube without Cuff with Murphy Eye – ID 2.0 mm | Medical Grade PVC, Neonatal Intubation, Box of 10 units (Ref. ETAN20002)

16,05 €

Oral endotracheal tube without cuff with Murphy eye with an internal diameter of 2.0 mm, made of transparent medical-grade polyvinyl chloride (PVC) and latex-free. Indicated for positive-pressure ventilation and administration of anaesthesia when the use of a face mask is not feasible, especially in neonatal intubation and very small airways. Its cuffless design fits anatomically against the tracheal wall, while the Murphy eye acts as an alternative ventilation pathway in the event of possible obstruction of the distal lumen. It incorporates a universal 15 mm connector (ISO 5356-1), radiopaque line and depth marks. Presentation in a box of 10 units, sterile and single-use, ideal for NICU, paediatric operating theatre and intubation trolleys. Reference ETAN20002, available for immediate delivery.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN20002

Description

1. Introduction

The Oral Cuffless Endotracheal Tube with Murphy Eye – ID 2.0 mm (ref. ETAN20002) is the airway solution that anaesthesia, emergency and intensive care services need to ensure ventilation of their patients when a face mask is not a viable option. Manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines durability, controlled flexibility and biocompatibility for critical procedures in small patients. It is supplied in a box of 10 units, individually packaged and sterile, designed to maintain a hospital stock always available in high-turnover units such as the NICU, the paediatric operating theatre and emergency bays.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. As it is a cuffless tube, sealing is achieved by the anatomical fit of the size against the tracheal wall, a common practice in very small airway sizes and in neonatal and premature patients, where cuff inflation is contraindicated or unnecessary.

The Murphy eye, a lateral opening located at the distal end, acts as an alternative ventilation route: if the main lumen becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, ensuring continuity of ventilation. The Magill curve, the rounded atraumatic tip, the radiopaque contrast line and the depth markings facilitate safe placement and radiographic verification. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.

3. Technical Specifications

The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETAN20002 (Cahnos own code)
Type Oral endotracheal tube (orotracheal), Magill curve
Access route Oral
Internal diameter (ID) 2.0 mm
Material Medical-grade polyvinyl chloride (PVC), transparent, flexible and durable
Latex Natural latex-free
Sleeve Cuffless (sealed by anatomical fit of the size)
Murphy eye Present, distal lateral safety orifice
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth markings
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, disposable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Indicative population Neonates and premature infants (sizes of 2.0 to 3.5 mm are commonly used)
Presentation Box of 10 units

The ETAN series of oral cuffless tracheal tubes with Murphy eye, to which this reference belongs, covers the following sizes in the same configuration and presentation of a box of 10 units:

Inner diameter Reference (box of 10 units)
2.0 mm ETAN20002 (this product)
2.5 mm ETAN25002
3.0 mm ETAN30002
3.5 mm ETAN35002
4.0 mm ETAN40002
4.5 mm ETAN45002
5.0 mm ETAN50002
5.5 mm ETAN55002
6.0 mm ETAN60002
7.0 mm ETAN70002
8.0 mm ETAN80002
9.0 mm ETAN90002
10.0 mm ETAN10002

Note: tracheal tubes are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch. The outer diameter (OD) and total length in this size could not be verified from official public sources of the manufacturer; they are pending confirmation with the technical department before use in tendering or stock replacement.

4. Equivalences and Cross-References

The SKU ETAN20002 is Cahnos’ own code (ETAN series) for this generic oral tracheal tube in PVC; it should not be confused with the official part number of any other specific manufacturer. To date, there is no equivalence table validated by the manufacturer for this reference, so we classify the following options according to their degree of correspondence:

Manufacturer / line Reference (ID 2.0 mm) Verification status
Cahnos – ENDOSID Magill cuffless with Murphy eye (own catalogue) 843020 Comparable confirmed in own catalogue: same configuration, size and indication; may differ in manufacturer and supply format
P. J. Dahlhausen – Magill cuffless endotracheal tube with Murphy eye (manufacturer’s official catalogue, article 4400011020) 44.000.11.020 Confirmed in the manufacturer’s official catalogue for 2.0 mm (newborn, sterile, with graduation, Murphy eye and depth mark)
Teleflex / Rüsch – Safety Clear® cuffless with Murphy eye 100382020 Confirmed in authorised distribution sources for 2.0 mm (single-use, sterile, with Murphy eye); verify against the manufacturer’s official datasheet

These references share clinical indication, size and general configuration (oral endotracheal tube without cuff, Magill curve, with Murphy eye), but may differ in the exact PVC compound, total length, outer diameter, bevel profile and marking system; therefore they should not be treated as direct equivalents without item-by-item verification against the manufacturer. There is no manufacturer-validated equivalence table for this generic distributor reference; consult the technical department of Cahnos before using it as an equivalence in specifications, tenders or direct substitution of another brand.

5. Selection tips and variants of interest

Size selection (usual practice in clinical use, not manufacturer specification): the 2.0 mm ID size is intended for premature and very low birth weight neonates; as a general guide, sizes from 2.0 to 3.5 mm are used in premature and neonatal patients depending on gestational age, weight and departmental protocol. The final choice must be based on the individual anaesthetic assessment of each patient, always selecting the largest size compatible with their anatomy. As it has no cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and the risk of aspiration in protocols where sealing is critical.

Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the 15 mm connector to the circuit; after placement, confirm the position using the radiopaque line and the depth marks. Single-use product: do not re-sterilise or reuse.

Variants of interest in the Cahnos catalogue: if you need another size, the uncuffed ETAN series covers from 2.0 mm to 10.0 mm (ETAN20002 to ETAN10002) in the same configuration; for the next size up, ETAN25002 (2.5 mm) and ETAN30002 (3.0 mm). In the ENDOSID airway management family, Ref. 843020 offers the same Magill configuration without cuff with Murphy eye, Ref. 842020 the version without Murphy eye (completely smooth internal lumen) and Ref. 845020 the emergency intubation kit of the same size. For procedures requiring an airtight seal or prolonged ventilation, consider the cuffed version of the same size; and for guiding the tube in very small airways, combine with the 2.0 mm PVC-coated aluminium intubation stylet (Ref. MA2023001). Consult our technical-commercial team at Cahnos for samples, volume conditions and the approval of references for your tender.

Additional information

Reference

ETAN20002 (Cahnos own code)

Product type

Oral endotracheal tube (orotracheal), Magill curve

Access route

Oral

Inner diameter

2.0 mm

Material

Medical-grade polyvinyl chloride (PVC), transparent, natural latex-free

Sleeve

Cuffless (sealed by anatomical fit of the size)

Murphy eye

Present, distal lateral safety orifice

Tip

Atraumatic, rounded and gently bevelled

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque contrast line and depth markings

Sterilisation

Ethylene oxide (EO), sterile, individually packaged

Use

Single-use, disposable

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Population

Neonates and premature infants (usual sizes 2.0–3.5 mm)

Presentation

Box of 10 units

Regulatory standard

Connector conforming to ISO 5356-1; tracheal tube conforming to ISO 5361