Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 5.0 mm – Box of 10 units (Ref. ETA050C02A2)

99,80 €

Reinforced oral endotracheal tube with cuff and Murphy eye, internal diameter (ID) 5.0 mm, manufactured from medical-grade polyvinyl chloride (PVC) with an integrated helical reinforcement that resists compression and kinking. Indicated for positive-pressure ventilation and administration of anaesthesia when face mask ventilation is not possible. Includes a high-volume, low-pressure inflatable cuff with pilot balloon, Murphy eye and universal 15 mm connector. Presentation: box of 10 sterile units for restocking ICU, operating theatre and emergency departments. Ref. ETA050C02A2.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA050C02A2

Description

1. Introduction

The oral reinforced endotracheal tube with cuff and Murphy eye ID 5.0 mm (ref. ETA050C02A2) is a single-use medical device designed to ensure a patent and stable airway in critical situations: positive pressure ventilation, administration of general anaesthesia and management of the patient in intensive care when mask ventilation is not possible. Its helical reinforcing armour makes it the reference option when tube movement, special positioning, head and neck surgery or risk of kinking are anticipated.

It is supplied in a box of 10 sterile units, ready for restocking intubation carts, ICU bays and operating theatres, ensuring a uniform and reliable standard in every airway procedure.

2. Technical explanation of the device and procedure

Orotracheal intubation consists of introducing the tube orally, through the glottis, until its distal end is placed in the trachea, below the vocal cords. The reinforced body (spiral incorporated in the PVC wall) prevents tube collapse under external compression, biting or kinking, maintaining airway patency in complex positions.

The high-volume, low-pressure cuff, inflated via the pilot balloon, seals the tracheal lumen and allows positive pressure ventilation without leaks, as well as preventing aspiration of secretions. The Murphy eye, a lateral opening near the distal tip, acts as a safety route: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this opening, preventing total occlusion.

3. Technical Specifications

Parameter Specification
Reference ETA050C02A2
Type Reinforced oral endotracheal tube with cuff
Internal diameter (ID) 5.0 mm
Access route Oral (orotracheal)
Material Medical-grade polyvinyl chloride (PVC), transparent
Reinforcement Integrated helical spiral, kink resistance
Sleeve High-volume, low-pressure cuff, with pilot balloon and Luer-Lock syringe valve
Murphy eye Present (distal lateral safety opening)
Connector Universal 15 mm (ISO 5356-1)
Radiopacity Radiopaque contrast line
Sterilisation Ethylene oxide (EO), sterile
Use Single-use
Indications Positive pressure ventilation and anaesthesia administration
Presentation Box of 10 units

Range of sizes available in Cahnos (ETA family, reinforced with cuff, without stylet):

Reference Internal diameter (ID)
ETA030C02A2 3.0 mm
ETA040C02A2 4.0 mm
ETA050C02A2 (this product) 5.0 mm
ETA055C02A2 5.5 mm
ETA060C02A2 6.0 mm
ETA070C02A2 7.0 mm
ETA080C02A2 8.0 mm
ETA010C02A2 10.0 mm

4. Equivalences and Cross-References

Functional category equivalence (not interchangeable 1:1). By clinical indication (oral reinforced endotracheal tube with cuff and Murphy eye, ID 5.0 mm) this product is comparable to helical reinforced tubes from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™ / Mallinckrodt™) and ICU Medical (Portex® Blue Line®). All these brands offer armoured oral tubes to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared specification by specification before replacing a specific product.

Comparable by category with official manufacturer catalogue: reference 44.000.20.050 (P. J. Dahlhausen & Co. GmbH, Woodbridge endotracheal tube series with cuff, ID 5.0 mm) is verified in the manufacturer’s official catalogue. It includes a stylet (Woodbridge model), unlike this product without stylet, so it is considered comparable at category level and not interchangeable 1:1.

The reference ETA050C02A2 is a proprietary code of Cahnos; it does not correspond to an official manufacturer part number published in public sources, so it must be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before use in tenders or as stock replacement.

Comparable by category within the Cahnos catalogue (same ID 5.0 mm, other configurations):

Reference Description
ETAM50C02A1 Oral reinforced endotracheal tube with cuff, stylet and Murphy eye (reinforcement + stylet)
ETAN50C02 Oral endotracheal tube with cuff and Murphy eye, without reinforcement (pending confirmation)
ETPN50C02 Preformed nasal tracheal tube with cuff and Murphy eye (pending confirmation)
ETSL50C02 Oral endotracheal tube with cuff and subglottic suction lumen (pending confirmation)

These references are comparable at category level, not interchangeable 1:1: each configuration addresses a specific indication (reinforcement, subglottic suction, nasal route, etc.).

5. Selection tips and variants of interest

The 5.0 mm ID is a size commonly used in paediatric patients and small-built adults; always select the largest size compatible with the patient’s anatomy and the centre’s protocol. As a clinical reference, paediatric sizes typically range from 3.0 to 6.0 mm depending on age and weight.

Verify the integrity of the cuff and pilot balloon before insertion and control the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).

The reinforced tube without stylet is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated. If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL50C02). For procedures requiring insertion assistance, the reinforced tube with stylet ETAM50C02A1 can be selected; for nasal approaches, the preformed ETPN50C02.

For volume conditions, samples or hospital supply lead times, contact the technical and commercial department of Cahnos.

Additional information

Material

Medical-grade polyvinyl chloride (PVC), transparent

Inner diameter

5.0 mm (ID)

Access route

Oral (orotracheal)

Product type

Reinforced with integrated helical spiral, without stylet

Sleeve

High-volume, low-pressure cuff with pilot balloon and Luer-Lock valve

Murphy eye

Present (distal lateral safety opening)

Connector

Universal 15 mm (ISO 5356-1)

Radiopaque

Yes, radiopaque contrast line

Sterilisation

Ethylene oxide (EO), sterile, single-use

Presentation

Box of 10 units

Indications

Positive pressure ventilation and anaesthesia administration

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 5.0 mm – Box of 10 units (Ref. ETA050C02A2)”

Your email address will not be published. Required fields are marked *