We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Preformed Nasal Endotracheal Tube with Cuff and Murphy Eye – ID 7.5 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETPN75C02)

36,45 €

Preformed nasal endotracheal tube with cuff and Murphy eye, ID 7.5 mm (ref. ETPN75C02), manufactured in medical-grade polyvinyl chloride (PVC), transparent, latex-free and single-use. Its preformed nasal curvature follows the anatomy of the airway, facilitates tube fixation and keeps the ventilation circuit away from the surgical field, while the sealing cuff, inflated via the pilot balloon with self-sealing valve, ensures positive-pressure ventilation without significant leaks. Includes Murphy eye, standard 15 mm connector compatible with ISO circuits, radiopaque line and depth scale. Indicated for anaesthesia and mechanical ventilation when a face mask is not viable. Presentation in a box of 10 units, ideal for anaesthesia, emergency and intensive care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETPN75C02

Description

1. Introduction

The preformed nasal endotracheal tube with cuff and Murphy eye of ID 7.5 mm (ref. ETPN75C02) is a single-use airway device designed to ensure safe, rapid and reproducible nasotracheal intubation in anaesthesia, intensive care and emergency settings. Its preformed geometry and sealing cuff provide stability and patient comfort, facilitate correct positioning in the nasopharynx and reduce the risk of accidental displacement during ventilation. It is supplied in a box of 10 units, individually packaged and sterile, ready for immediate use in the operating theatre, ICU and emergency departments.

2. Technical explanation of the device and procedure

In nasotracheal intubation, the tube is inserted through one of the nostrils, passes through the nasopharynx, the glottis and sits in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The preformed curve follows the anatomy of the upper airway: it facilitates fixation of the tube over the patient’s forehead, minimises tissue trauma and prevents the circuit from interfering with the surgical field in oral, maxillofacial, ENT and ophthalmic surgery.

The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive pressure ventilation without significant leaks. The Murphy eye, a distal lateral orifice, ensures an alternative gas passage if the tube tip becomes obstructed (by secretions or by the bevel resting against the tracheal wall). The continuous radiopaque line and depth scale allow radiographic confirmation of correct placement. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference ETPN75C02
Type Preformed nasal tracheal tube with cuff and Murphy eye
Access route Nasal (nasopharyngeal), preformed RAE-type curvature
Internal diameter (ID) 7.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Yes, inflatable, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Connector 15 mm standard, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque line and depth scale
Latex Natural rubber latex-free
Use Single-use (sterile, individually packaged)
Indication Positive pressure ventilation and anaesthesia administration when a ventilation face mask is not viable
Presentation Box of 10 units

Note: the outer diameter (OD) and total length of the 7.5 mm size of the ETPN series could not be verified in official public sources; they are pending confirmation with the manufacturer before use in tenders or stock replacement.

Other sizes in the same family (ETPN series, same design and presentation, confirmed in the Cahnos catalogue):

Inner diameter SKU (box of 10 units)
3.5 mm ETPN35C02
4.5 mm ETPN45C02
5.0 mm ETPN50C02
5.5 mm ETPN55C02
6.5 mm ETPN65C02
7.0 mm ETPN70C02
7.5 mm ETPN75C02 (this product)

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETPN75C02 is own code of Cahnos for this generic reference of preformed nasal tube in PVC with cuff and Murphy eye; it must not be confused with the official part number of any specific manufacturer, so no exact reference equivalence can be declared and there is no manufacturer-validated equivalence table. Consult the technical department of Cahnos before using this reference in specifications or tenders.

Comparable at category level (not 1:1 interchangeable): preformed nasal tubes with cuff and Murphy eye from lines such as Rüsch® AGT Nasal Cuffed from Teleflex (the 7.5 mm reference, 111781075, appears confirmed in the manufacturer’s online catalogue for the US market), Shiley™ RAE nasal with TaperGuard™ cuff from Medtronic, RAE preformed tubes from Pinmed or preformed nasal tubes from BOENMED respond to the same clinical indication and general geometry. They differ in cuff material, length, cuff design and inflation pressure, so they must be checked against the official technical data sheet before use. In the Dahlhausen catalogue (Magill preformed line, ref. 44.000.30.xxx, distributed by Cahnos) there is a configuration with cuff in size 7.5 mm as a reference for the same functional category.

Comparables by category within the Cahnos catalogue (same ID 7.5 mm, other configurations): ETAN75C02 (oral endotracheal tube with cuff and Murphy eye), ETPO75C02 (preformed oral endotracheal tube), ETSL75C02 (oral endotracheal tube with subglottic suction lumen) and ETA075C02A2 (reinforced tube). All are comparable at category level, not 1:1 interchangeable. There is no manufacturer-validated equivalence table for this reference; consult the technical department before use in tenders.

5. Selection tips and variants of interest

Patient selection (usual practice in clinical use, not manufacturer specification): the ID 7.5 mm size is a common size in adult patients; as a general guide, tubes of 7.0 to 9.0 mm are usually used depending on build, always selecting the largest size compatible with the patient’s anatomy. The final choice should be based on the department’s protocol and anaesthetic assessment.

Cuff pressure: inflate through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal mucosal damage; monitor with a manometer if available in the department.

Preferred indications: oral, maxillofacial, ENT and ophthalmic surgery, where it is important to keep the circuit out of the operative field, as well as mechanical ventilation in intensive care. Before intubation, check the integrity of the cuff, pilot balloon and lumen patency.

Variants of interest in the catalogue: if you need another size, the ETPN series covers from 3.5 mm to 7.5 mm (ETPN35C02 to ETPN75C02). For intubation requiring kink resistance or frequent repositioning, consider the reinforced tubes in the intubation section of Cahnos. Contact the technical department of Cahnos for samples, volume conditions and hospital supply lead times.

Additional information

Reference

ETPN75C02

Product type

Preformed nasal tracheal tube with cuff and Murphy eye

Access route

Nasal (nasopharyngeal), preformed RAE-type curvature

Inner diameter

7.5 mm

Material

Medical-grade polyvinyl chloride (PVC), transparent, latex-free

Sleeve

Yes, inflatable, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Connector

15 mm standard (ISO 5356-1)

Marking

Radiopaque line and depth scale

Use

Single-use, sterile

Sterilisation

Ethylene oxide (EO), individually packaged

Regulatory standard

ISO 5361 (tracheal tubes); CE per MDR (verify batch)

Presentation

Box of 10 units

Indications

Positive-pressure ventilation and anaesthesia when a face mask is not viable

Reviews

There are no reviews yet.

Be the first to review “Preformed Nasal Endotracheal Tube with Cuff and Murphy Eye – ID 7.5 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETPN75C02)”

Your email address will not be published. Required fields are marked *