Description
Introduction
The tracheostomy tube with cuff in 6.0 mm diameter (Ref. 57679) is a sterile, single-use airway device designed to provide a patent airway quickly and safely in emergency situations. Its curved tube is inserted directly through the tracheostomy stoma, a surgically created opening in the neck and trachea, and is particularly indicated for intensive care units, emergency departments, anaesthesia and airway units. Made of medical-grade PVC, transparent, non-toxic and kink-resistant, it protects the delicate mucosal tissue during use.
Technical explanation of the device and procedure
These curved tubes are designed to create an airway within seconds by insertion into the tracheostomy stoma. The hollow tube, with or without cuff, is placed directly into the trachea through a surgical incision, using a wire-guided progressive dilatation technique. The high-volume, low-pressure cuff provides an effective airway seal, while the non-return valve allows the cuff to be inflated and deflated easily via the pilot balloon, ensuring atraumatic intubation and extubation.
- Medical-grade PVC tube, non-toxic, transparent and kink-resistant, which protects mucosal tissue.
- Smooth, rounded obturator tip that reduces trauma during insertion.
- Cervical plate with printed size for quick and easy identification.
- Standard connector.
- Radiopaque line that helps determine the exact position of the tube.
The tube includes: cuff, inflation line, valve, pilot balloon, obturator, cervical plate, connector and fixation tapes. The thin, soft-walled cuff ensures an effective seal and trauma-free intubation and extubation manoeuvres.
Technical specifications
| Characteristic | Specification |
|---|---|
| Device type | Tracheostomy tube with cuff |
| Diameter | 6.0 mm |
| Material | Medical-grade PVC, non-toxic, transparent and kink-resistant |
| Sleeve | High volume and low pressure, with pilot balloon and non-return valve |
| Connector | Standard |
| Marking | Cervical plate with printed size and radiopaque line |
| Contents | Cuff, inflation line, valve, pilot balloon, obturator, cervical plate, connector and fixation tapes |
| Sterility | Sterile, single-patient |
| Latex | Without natural rubber or latex |
| Phthalates | DEHP-free |
| Classification | Class IIa |
| Presentation | Box of 10 units |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 10 units |
| Device type | Medical device |
| Device class | II A |
| CND | R0105020102 |
| EAN | 6972091921240 |
Equivalences and cross-references
The reference 57679 is the manufacturer’s own code for this tracheostomy tube with cuff of Ø 6.0 mm. There is no manufacturer-validated equivalence table that allows it to be cross-referenced directly 1:1 with codes from other suppliers; it is recommended to consult with the technical department of Cahnos before using it in tenders or stock replacement protocols.
Comparable at category level (not interchangeable 1:1): within the Cahnos catalogue, the SUMI tracheostomy tube compatible with magnetic resonance imaging (SuMRI range, series 37-xx60 with cuff and 38-xx60 without cuff) performs the same clinical function in the 6.0 mm size (ref. 37-6060 with cuff), although it incorporates a plastic spiral reinforcement suitable for MRI. Also comparable by category are the percutaneous tracheostomy kits from the TP02 series, which include low-pressure cuffed tracheostomy tubes and a universal 15 mm connector.
Selection tips and variants of interest
- The 6.0 mm size is a size commonly indicated for patients with a small airway or as an access tube in adults of smaller build; the final selection should be based on the service protocol and the patient’s clinical assessment.
- The cuff should be inflated through the valve with a syringe and maintain a sealing pressure within the usual clinical practice range (20-30 cmH2O) to minimise tracheal mucosal damage; monitoring with a manometer is recommended when the service has one available.
- Before use, check the integrity of the cuff, the pilot balloon and the patency of the lumen, as well as the validity of the sterile packaging and its expiry date.
- Single-use item: after each patient it must be discarded to avoid the risk of cross-infection, following the current healthcare waste management regulations.
- For percutaneous dilatation tracheostomy procedures with all instruments included, please refer to the TP02 series kits available in the Cahnos catalogue.