We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 8.0 mm | Medical-Grade PVC, Single-Use | Ref. ETA080C02A2 | Box of 10 units

99,80 €

Reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.0 mm (Ref. ETA080C02A2), manufactured from medical-grade polyvinyl chloride (PVC), transparent and latex-free. Its anti-kink helical spiral keeps the airway patent and stable during head and neck movements, external compression or complex surgical positions, being the usual choice in anaesthesia, emergency and intensive care for positive-pressure ventilation when a face mask is not viable. It includes a sealing cuff with pilot balloon and self-sealing valve, universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation. Presentation in a box of 10 units, sterile and single-use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA080C02A2

Description

1. Introduction

The reinforced oral endotracheal tube with cuff and Murphy eye of 8.0 mm (Ref. ETA080C02A2) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables, ensuring a uniform and reliable standard in every procedure.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents collapse of the tube under external compression, biting or kinking, making it especially suitable for head and neck, ENT, maxillofacial, thyroid surgeries, prone positioning and complex surgical positions.

The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety route: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through that opening and occlusion is never complete. The universal 15 mm connector (ISO 5356-1), radiopaque line and depth graduation allow connection to the circuit and radiographic verification of position. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference (SKU) ETA080C02A2 (distributor’s own code Cahnos; ETA series: reinforced with cuff, without stylet)
Type Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced
Access route Oral (orotracheal)
Internal diameter (ID) 8.0 mm (standard adult size)
Reinforcement Anti-kink helical spiral integrated into the tube wall
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Sealing (cuff inflation), with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units
Indicative population Adult
Regulatory standard ISO 5361 (tracheal tubes); connector ISO 5356-1; sterilisation according to EN ISO 11135-1; verify CE/MDR marking of each batch

Range of sizes available at Cahnos (ETA family, reinforced with cuff and Murphy eye, without stylet):

Reference Internal diameter (ID) Indicative patient
ETA030C02A2 3.0 mm Newborn
ETA040C02A2 4.0 mm Child
ETA050C02A2 5.0 mm Child
ETA055C02A2 5.5 mm Child / small adult
ETA060C02A2 6.0 mm Small adult
ETA070C02A2 7.0 mm Adult
ETA080C02A2 (this product) 8.0 mm Adult
ETA010C02A2 10.0 mm Large adult

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, the CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

4. Equivalences and Cross-References

The reference ETA080C02A2 is an own code from the Cahnos catalogue (ETA series: reinforced oral tracheal tubes with cuff, without stylet) and must not be confused with the official reference number of any specific manufacturer. As of today, there is no equivalence table validated by the manufacturer for this reference, so the following options are classified as comparable at category level (not interchangeable 1:1), pending technical verification against the official data sheet of each manufacturer:

Reference / Line Description Degree of correspondence
849080 / 849080-M (ENDOSID® / Asid Bonz) Spiral reinforced endotracheal tube with high-volume low-pressure cuff and Murphy eye, 8.0 mm; the -M variant includes an intubation stylet Comparable by category; verify inflation system, outer diameter and guide
44.000.20.080 (P. J. Dahlhausen) Reinforced endotracheal tube with cuff (Woodbridge type), ID 8.0 mm, PVC, sterile Comparable by category; verify presence of Murphy eye and connector
44.000.10.080 (P. J. Dahlhausen) Magill-type endotracheal tube with cuff and Murphy eye, 8.0 mm Comparable by category; differs in reinforcement (without helical armouring)
118-80M (Safety-Flex, Mallinckrodt/Teleflex) Reinforced endotracheal tube with cuff and Murphy tip, 8.0 mm, 15 mm connector Comparable by category; pending verification of official data sheet
Rüsch® / Sheridan® (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical Reinforced cuffed endotracheal tube lines on the market Comparable by category; not interchangeable 1:1 without verification of datasheet and IFU

Criteria verified before comparison: internal diameter (8.0 mm), material (medical grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands.

Comparable by category within the Cahnos catalogue (same size 8.0 mm, not interchangeable 1:1):

Reference Description Key difference
ETAM80C02A1 Reinforced oral tube with cuff, insertion stylet and Murphy eye, ID 8.0 mm Adds included insertion stylet
ETA080002A2 Reinforced oral tube without cuff, with Murphy eye, ID 8.0 mm Without cuff
ETAN80C02 Oral tube with cuff and Murphy eye, ID 8.0 mm Without helical reinforcement
ETSL80C02 Oral tube with cuff and subglottic suction lumen, ID 8.0 mm Adds subglottic suction for prevention of VAP
ETPN80C02 Preformed nasal tracheal tube with cuff and Murphy eye, ID 8.0 mm Preformed geometry, nasal approach

5. Selection tips and variants of interest

Size selection: the ID of 8.0 mm is one of the most demanded sizes in adult intubation. As a general clinical practice guideline (not manufacturer specification), tubes of 7.0 to 9.0 mm are used depending on build and airway (7.0–7.5 mm in women and 7.5–8.5 mm in men), always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.

Cuff pressure: check the integrity of the cuff, pilot balloon and patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range; confirm service protocol) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one.

Variants of interest: if insertion assistance is required, consider Ref. ETAM80C02A1 (same size, with guide); if the procedure is short and it is preferred to avoid the balloon, Ref. ETA080002A2 (reinforced without cuff); in case of risk of ventilator-associated pneumonia (VAP) during prolonged intubations, consult the line with subglottic suction lumen (ETSL80C02). Complete the intubation trolley stock with the adjacent sizes of the range (ETA070C02A2, ETA085C02A2). Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department of Cahnos for samples, volume conditions and the approval of references for your tender.

Additional information

Reference

ETA080C02A2 (distributor's own code Cahnos)

Product type

Reinforced oral (orotracheal) endotracheal tube, with cuff

Access route

Oral (orotracheal)

Inner diameter

8.0 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Reinforcement

Anti-kink helical spiral integrated into the tube wall

Intubation guide

Not included

Sleeve

Sealing, with pilot balloon and self-sealing valve

Murphy eye

Present, distal lateral safety orifice

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque line and depth graduation

Sterilisation

Ethylene oxide (EO), sterile, individual packaging

Use

Single-use, non-reusable

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Presentation

Box of 10 units

Regulatory standard

ISO 5361; connector ISO 5356-1; sterilisation according to EN ISO 11135-1

Tipo paciente

Adult

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 8.0 mm | Medical-Grade PVC, Single-Use | Ref. ETA080C02A2 | Box of 10 units”

Your email address will not be published. Required fields are marked *