We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Preformed Nasal Tracheal Tube with Cuff and Murphy Eye, ID 5.5 mm – Medical-Grade PVC, Single-Use, Box of 10 units (SKU ETPN55C02)

36,45 €

Preformed nasal tracheal tube with cuff and Murphy eye, internal diameter (ID) of 5.5 mm, manufactured from medical-grade polyvinyl chloride (PVC) and single-use. Its preformed nasal curvature follows the anatomy of the airway, facilitates tube fixation and keeps the ventilation circuit away from the surgical field, while the sealing cuff ensures positive-pressure ventilation without significant leaks. Includes Murphy eye, pilot balloon with self-sealing valve, radiopaque line, depth scale and standard 15 mm connector compatible with ISO circuits. Indicated for anaesthesia administration and mechanical ventilation when the use of a face mask is not feasible. Presentation in box of 10 units, ideal for anaesthesia, emergency and intensive care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETPN55C02

Description

1. Introduction

The Preformed Nasal Tracheal Tube with Cuff and Murphy Eye, ID 5.5 mm (SKU: ETPN55C02) is a single-use airway device designed to ensure safe, rapid and reproducible nasotracheal intubation in anaesthesia, intensive care and emergency settings. Its preformed geometry and sealing cuff provide stability and patient comfort, facilitating correct positioning in the nasopharynx and reducing the risk of accidental displacement during ventilation.

2. Technical explanation of the device and procedure

In nasotracheal intubation, the tube is inserted through one of the nostrils, passes through the nasopharynx, the glottis and sits in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The preformed curve follows the anatomy of the upper airway: it facilitates tube fixation, minimises tissue trauma and prevents the circuit from interfering with the surgical field in oral, maxillofacial, ENT and ophthalmic surgery.

The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive pressure ventilation without significant leaks. The Murphy eye, a distal lateral opening, ensures an alternative gas passage if the tube tip becomes obstructed (by secretions or by the bevel resting against the tracheal wall). The continuous radiopaque line and depth scale allow radiographic confirmation of correct placement. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference ETPN55C02
Type Preformed nasal tracheal tube with cuff and Murphy eye
Access route Nasal (nasopharyngeal), preformed curvature
Internal diameter (ID) 5.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent and thermosensitive
Sleeve Yes, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Connector 15 mm standard, compatible with ISO circuits
Marking Radiopaque line and depth scale
Latex Latex-free
Use Single-use (sterile)
Indication Positive pressure ventilation and anaesthesia administration when a ventilation face mask is not viable
Presentation Box of 10 units

Note: the outer diameter (OD) and total length of the 5.5 mm size could not be verified in official public sources; they remain pending confirmation with the manufacturer before use in tenders or stock replacement.

Other sizes in the same family (ETPN series, same design and presentation, confirmed in the Cahnos catalogue):

Inner diameter SKU (box of 10 units)
3.5 mm ETPN35C02
4.5 mm ETPN45C02
5.0 mm ETPN50C02
5.5 mm ETPN55C02 (this product)
6.5 mm ETPN65C02
7.5 mm ETPN75C02

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETPN55C02 is Cahnos’s own code for this generic reference of preformed nasal PVC tube with cuff and Murphy eye; it must not be confused with the official part number of any specific manufacturer, and therefore an exact reference equivalence cannot be declared, nor is there a manufacturer-validated equivalence table. Consult Cahnos’s technical department before using this reference in specifications or tenders.

  • Comparable at category level (not 1:1 interchangeable): preformed nasal tubes with cuff and Murphy eye from lines such as Rüsch® AGT/RAE and Sheridan® (Teleflex), Shiley™ RAE nasal with TaperGuard™ cuff (Medtronic) or BOENMED nasal preformed tubes respond to the same indication and general geometry. Any specific reference (cuff material, length and balloon design may differ) must be checked against the official technical data sheet before use; for the 5.5 mm size, confirmation with the manufacturer is still pending.
  • Comparable by category within the Cahnos catalogue (same ID 5.5 mm, other configurations): ETAN55C02 (oral endotracheal tube with cuff and Murphy eye) and ETPO55C02 (preformed oral endotracheal tube). All are comparable at category level, not 1:1 interchangeable.

5. Selection tips and variants of interest

Patient selection (usual practice in clinical use, not manufacturer specification): the ID 5.5 mm cuffed size is typically used in older paediatric patients, adolescents or adults with a narrow airway; the final choice must always be based on the department’s protocol and anaesthetic assessment (age, weight and estimated airway size).

Cuff pressure: inflate through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal mucosal damage; monitor with a manometer if available in the department.

Preferred indications: oral, maxillofacial, ENT and ophthalmic surgery, where it is important to keep the circuit out of the operative field, as well as mechanical ventilation in intensive care.

Variants of interest in the catalogue: if you need another size, the ETPN series covers from 3.5 mm to 7.5 mm (ETPN35C02 to ETPN75C02). For intubation requiring kink resistance or frequent repositioning, consider the reinforced tubes in the intubation section of Cahnos. Contact Cahnos’s technical department for samples, volume pricing and hospital supply lead times.

Additional information

Reference

ETPN55C02

Product type

Preformed nasal tracheal tube with cuff and Murphy eye

Access route

Nasal (nasopharyngeal), preformed curvature

Inner diameter

5.5 mm

Material

Medical-grade polyvinyl chloride (PVC)

Sleeve

Yes, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Connector

15 mm, compatible with ISO circuits

Marking

Radiopaque line and depth scale

Use

Single-use (sterile)

Presentation

Box of 10 units

Regulatory standard

Compliant with the requirements of ISO 5361 (tracheal tubes and connectors); verify the manufacturer's CE marking per batch

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Preformed Nasal Tracheal Tube with Cuff and Murphy Eye, ID 5.5 mm – Medical-Grade PVC, Single-Use, Box of 10 units (SKU ETPN55C02)”

Your email address will not be published. Required fields are marked *