We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 10.0 mm | Medical-Grade PVC, Single-Use | Ref. ETA010C02A2 | Box of 10 units

99,80 €

Reinforced oral endotracheal tube with cuff and Murphy eye, ID 10.0 mm (Ref. ETA010C02A2), manufactured from medical-grade polyvinyl chloride (PVC), transparent and latex-free. Its helical anti-kink spiral keeps the airway patent and stable during head and neck movements, external compression or complex surgical positions, being the usual choice in anaesthesia, emergency and intensive care for positive-pressure ventilation when a face mask is not viable. It includes a sealing cuff with pilot balloon and self-sealing valve, 15 mm universal connector (ISO 5356-1), radiopaque line and depth graduation. Presentation in a box of 10 units, sterile and single-use; verify the CE/MDR marking of each batch before use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA010C02A2

Description

1. Introduction

The reinforced oral endotracheal tube with cuff and Murphy eye of 10.0 mm (Ref. ETA010C02A2) is the airway solution that anaesthesia, emergency and intensive care services need when mask ventilation is not viable and the largest size in the range is required for large adult patients. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the resistance of the anti-kink helical reinforcement with the airtight sealing of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is presented in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables, guaranteeing a uniform and reliable standard in each procedure.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents the tube from collapsing under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial, thyroid, prone positioning and complex surgical positions.

The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral orifice, acts as a safety pathway: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through that opening and occlusion is never total. The universal 15 mm connector (ISO 5356-1), the radiopaque line and the depth graduation allow connection to the circuit and radiographic verification of position. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETA010C02A2 (Cahnos distributor’s own code; ETA series: reinforced with cuff, without guide)
Type Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced
Access route Oral (orotracheal)
Internal diameter (ID) 10.0 mm (maximum size in the range; large adult)
Reinforcement Anti-kink helical spiral integrated into the tube wall
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Sealing (cuff inflation), with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units
Indicative population Large adult (larger size in the range for large-built adult patients)
Regulatory standard ISO 5361 (tracheal tubes); connector ISO 5356-1; verify CE/MDR marking of each batch

This size belongs to the Cahnos range of reinforced oral endotracheal tubes with cuff and Murphy eye (ETA…C02A2 series, without guide), available in various diameters to complete the service’s stock:

Reference Internal diameter (ID) Indicative patient
ETA030C02A2 3.0 mm Newborn
ETA040C02A2 4.0 mm Child
ETA050C02A2 5.0 mm Child
ETA055C02A2 5.5 mm Child / small adult
ETA060C02A2 6.0 mm Small adult
ETA070C02A2 7.0 mm Adult
ETA075C02A2 7.5 mm Adult
ETA080C02A2 8.0 mm Adult
ETA085C02A2 8.5 mm Adult / large adult
ETA010C02A2 (this product) 10.0 mm Large adult

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

4. Equivalences and Cross-References

The reference ETA010C02A2 is a Cahnos catalogue own code (ETA series: reinforced oral tracheal tubes with cuff, without guide) and should not be confused with the official reference number of any specific manufacturer. For this maximum size (10.0 mm, oral, reinforced, with cuff and Murphy eye) there is no equivalence table validated by the manufacturer in the official sources consulted; therefore, the following references are offered as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official data sheet:

Manufacturer / Line Reference Description Degree of correspondence
Intersurgical (InTube™) 8060100 Tracheal tube with wire reinforcement and cuff, ID 10.0 mm, box of 10 units (manufacturer’s official catalogue) Comparable by category; same size and configuration, another manufacturer; verify HVLP cuff, Murphy eye and connector
P. J. Dahlhausen (Woodbridge) 4400020100 Reinforced endotracheal tube with cuff and guide (integrated stylet), ID 10.0 mm, PVC, sterile (manufacturer’s official catalogue) Comparable by category; differs in including insertion guide; verify Murphy eye and inflation system
ENDOSID® / Asid Bonz (Medline) Range 849xxx (spiral with cuff) The spiral line reinforced with cuff and Murphy eye is officially documented up to 9.0 mm, with no coverage in 10.0 mm No direct correspondence in 10.0 mm according to official catalogue; not applicable as an equivalent in this size
Teleflex (Rüsch® / Sheridan®), Medtronic (Shiley™), ICU Medical (Portex®) No verified code for 10.0 mm Families of reinforced cuffed tubes on the market that cover large adult sizes Comparable by category; pending confirmation of reference and technical data sheet for 10.0 mm

Fields to be checked before comparing: internal diameter (10.0 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement. There is no equivalence table validated by the manufacturer for this reference; consult the Cahnos technical department before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands.

Alternatives within the Cahnos catalogue with the same 10.0 mm size (not interchangeable 1:1):

Reference Description Key difference
ETA010002A2 Reinforced oral tube without cuff, with Murphy eye, ID 10.0 mm Without cuff
ETAM10C02A1 Reinforced oral tube with cuff, insertion guide and Murphy eye, ID 10.0 mm Adds included insertion stylet
ETA085C02A2 Reinforced oral tube with cuff and Murphy eye, ID 8.5 mm Smaller size, adult / large size

5. Selection tips and variants of interest

Size selection: the 10.0 mm ID is the largest size in this family and is reserved for large adult patients or wide airways. As a general clinical practice guideline (not a manufacturer specification), tubes of 7.0 to 10.0 mm are used in adults depending on build and airway, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol: an excessive size can damage the tracheal mucosa and an insufficient one causes leaks and loss of sealing pressure.

Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range; confirm the department’s protocol) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the department has one.

Variants of interest: if insertion assistance is required, consider Ref. ETAM10C02A1 (same size, with guide); if the procedure is short and avoiding the cuff is preferred, Ref. ETA010002A2 (reinforced without cuff). To complete the adult intubation trolley, cover the adjacent sizes in the range (ETA080C02A2 and ETA085C02A2) and, in the event of risk of ventilator-associated pneumonia (VAP) in prolonged intubations, consult the lines with subglottic suction lumen (ETSL series). Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department at Cahnos for samples, volume pricing and approval of references for your tender.

Additional information

Reference

ETA010C02A2

Product type

Oral endotracheal tube (orotracheal) reinforced with cuff, Magill curve

Access route

Oral (orotracheal)

Inner diameter

10.0 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Reinforcement

Helical anti-kink spiral integrated into the wall

Sleeve

Sealing (cuff inflation), with pilot balloon and self-sealing valve

Murphy eye

Present (distal lateral safety opening)

Tips

Atraumatic, rounded and gently bevelled

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque contrast line and depth graduation

Sterilisation

Ethylene oxide (EO), sterile

Use

Single-use, non-reusable

Presentation

Box of 10 units

Indicative population

Large adult (maximum size in the range)

Regulatory standard

ISO 5361; connector ISO 5356-1; verify CE/MDR per batch

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 10.0 mm | Medical-Grade PVC, Single-Use | Ref. ETA010C02A2 | Box of 10 units”

Your email address will not be published. Required fields are marked *