Description
1. Orotracheal endotracheal tube ID 8.5 mm with cuff and Murphy eye
The endotracheal tube ETAN85C02 is a single-use device designed to ensure safe and effective ventilation in critical clinical settings: intensive care, emergency, anaesthesia and resuscitation. Its body is made of medical-grade polyvinyl chloride (PVC), a material with sufficient rigidity for guided placement and the flexibility needed to adapt to the patient’s anatomy. It is supplied in a box of 10 units, intended for restocking intubation trolleys, ICU bays and operating theatres with a very competitive value for money.
2. Technical explanation of the product and procedure
Orotracheal intubation involves introducing the tube orally until its distal end is positioned in the trachea, below the vocal cords, creating a patent airway for positive pressure ventilation and administration of anaesthesia when a face mask cannot be used. The cuff (inflated via the pilot balloon with a syringe) seals the tracheal lumen against the tube: it prevents gas leaks, prevents aspiration of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral hole near the tip, acts as a safety pathway: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this hole and occlusion is never complete. The internal diameter (ID) of 8.5 mm is characteristic of tubes for medium-large adults and allows good gas flow with acceptable resistances.
3. Technical Specifications
| Material | Medical-grade polyvinyl chloride (PVC) |
| Type | Orotracheal (oral route) with cuff and Murphy eye |
| Internal diameter (ID) | 8.5 mm |
| Sleeve | Inflatable, sealed via pilot balloon |
| Murphy eye | Present (lateral safety hole) |
| Connector | 15 mm universal (ISO 5356-1) |
| Indications | Positive pressure ventilation and anaesthesia |
| Presentation | Box of 10 units |
Range of sizes available at Cahnos (ETAN family):
| Reference | Internal diameter (ID) |
| ETAN25C02 | 2.5 mm |
| ETAN35C02 | 3.5 mm |
| ETAN45C02 | 4.5 mm |
| ETAN55C02 | 5.5 mm |
| ETAN65C02 | 6.5 mm |
| ETAN75C02 | 7.5 mm |
| ETAN85C02 | 8.5 mm |
4. Equivalences and Cross-References
ETAN85C02 is a proprietary code of Cahnos; it does not correspond to an official manufacturer part number published in public sources, so it should be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code.
Functional category comparison (not interchangeable 1:1): by clinical indication (endotracheal tube with cuff and Murphy eye, ID 8.5 mm for adults) it is comparable to tubes from manufacturers such as DEAS S.r.l. (DEAFLUX line) or Teleflex (Rüsch). However, these brands do not publish a validated equivalence table for the ETAN85C02 code: they differ in outer diameter (OD), total length, geometry and cuff material, so it must be cross-checked spec sheet by spec sheet before replacing a specific product.
Reference data for dimension comparison (ETSL line from DEAS S.r.l. with subglottic suction, available at Cahnos as ETSL85C02):
| Reference | ID (mm) | OD (mm) | Length (mm) | Cuff diameter (mm) |
| ETSL60C02 | 6.0 | 9.6 | 285 | 20 |
| ETSL65C02 | 6.5 | 10.2 | 295 | 20 |
| ETSL70C02 | 7.0 | 10.8 | 310 | 25 |
| ETSL75C02 | 7.5 | 11.5 | 315 | 25 |
| ETSL80C02 | 8.0 | 12.2 | 330 | 26 |
| ETSL85C02 | 8.5 | 12.9 | 330 | 26 |
| ETSL90C02 | 9.0 | 13.6 | 330 | 28 |
There is no equivalence table validated by the manufacturer for ETAN85C02; consult the technical department of Cahnos before using in a tender.
5. Selection tips and variants of interest
- The ID 8.5 mm size is appropriate for medium-large adults; the usual intubation range in adults is ID 7.0-8.5 mm. The final selection should be based on assessment of the patient’s glottic diameter and the usual practice of the department.
- After inflation, maintain the cuff pressure within the usual clinical range (ideally 20-30 cmH2O) with a manometer, to minimise damage to the tracheal mucosa during prolonged ventilation.
- Verify the outer diameter (OD) and total length against the spec sheet of the product you wish to replace: two tubes with the same ID may have different OD and length.
- Variants of interest at Cahnos in the same ID 8.5 mm size: with subglottic suction lumen ETSL85C02 (prolonged intubations and prevention of ventilator-associated pneumonia), reinforced ETA085C02A2, reinforced with stylet ETAM85C02A1 and preformed ETPO85C02.
- The ETAN family is available in sizes from 2.5 to 8.5 mm (ETAN25C02 to ETAN85C02), covering from paediatric patients to tall adults.