Description
1. Commercial Introduction
The 5.0 mm internal diameter oral endotracheal tube with cuff and Murphy eye (ref. ETAN50C02) is a single-use airway device designed for orotracheal intubation in anaesthesia, intensive care, emergency and resuscitation. Manufactured in transparent, latex-free medical-grade polyvinyl chloride (PVC), it combines a sealing cuff with the characteristic distal Murphy eye to provide safe, leak-free positive-pressure ventilation when a ventilation face mask is not viable. It is supplied in a box of 10 units, individually packaged and ready for immediate use in the operating theatre, ICU and emergency departments.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, also reducing the risk of aspiration. The Murphy eye, a lateral opening at the distal end, acts as an alternative gas passage if the tip of the tube becomes obstructed by secretions or by the bevel resting against the tracheal wall. The Magill curve, rounded atraumatic tip, radiopaque line and depth marks facilitate safe placement and radiographic verification. It is a single-use device: it must be discarded after each patient to avoid the risk of cross-infection. The 5.0 mm size is frequently used in older paediatric patients or adults with a reduced-calibre airway.
3. Technical Specifications
| Parameter | Specification |
| Reference | ETAN50C02 |
| Type | Oral endotracheal tube (Magill curve) with cuff and Murphy eye |
| Internal diameter (ID) | 5.0 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, inflatable, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral safety opening |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Use | Single-use (sterile, individually packaged) |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Technical note: the outer diameter (OD), total length and recommended cuff inflation pressure for this size could not be verified in official public sources from the manufacturer; they are pending confirmation with the technical department before use in tenders or stock replacement.
Other sizes in the same family (ETAN series, same oral design with cuff and Murphy eye, confirmed in the Cahnos catalogue):
| Inner diameter | SKU (box of 10 units) |
| 2.5 mm | ETAN25C02 |
| 3.0 mm | ETAN30C02 |
| 3.5 mm | ETAN35C02 |
| 4.0 mm | ETAN40C02 |
| 4.5 mm | ETAN45C02 |
| 5.0 mm | ETAN50C02 (this product) |
| 5.5 mm | ETAN55C02 |
| 6.0 mm | ETAN60C02 |
| 6.5 mm | ETAN65C02 |
| 7.0 mm | ETAN70C02 |
| 7.5 mm | ETAN75C02 |
| 8.0 mm | ETAN80C02 |
| 8.5 mm | ETAN85C02 |
| 9.0 mm | ETAN90C02 |
| 9.5 mm | ETAN95C02 |
| 10.0 mm | ETAN10C02 |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; check the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch.
4. Equivalences and Cross-References
SKU ETAN50C02 is Cahnos’s own code and the ETAN family corresponds to the nomenclature of the DEAFLUX line (DEAS S.r.l.) of Magill tracheal tubes with cuff; it must not be confused with other lines from the same manufacturer (preformed ETPO/ETPN, suction lumen ETSL or reinforced ETA) nor with the official part number of any other manufacturer. Therefore, no exact reference equivalence can be declared and there is no manufacturer-validated equivalence table; consult Cahnos’s technical department before using this reference in specifications or tenders.
Comparable at category level (not 1:1 interchangeable):
- Endosid with low-pressure cuff and Murphy eye, ref. 841050 (Cahnos’s own catalogue): same 5.0 mm size and same configuration with cuff and Murphy eye; they may differ in PVC compound, length, cuff inflation pressure and bevel design.
- P. J. Dahlhausen, Magill-type tube with cuff and Murphy eye, ref. 44.000.10.050, and uncuffed version 44.000.11.050 (series documented in the manufacturer’s official catalogue): same indication and general geometry with sealing cuff.
- ISSO PRO-BREATHE, suction line size 5, ref. PB-212050U: comparable by category; verify cuff type, presence of Murphy eye and connector standard before replacing.
- Teleflex (Rüsch) and ICU Medical (Portex) ranges: same functional families of cuffed tracheal tubes; no specific 5.0 mm codes are listed as they have not been verified against an official source, pending confirmation with the manufacturer.
Comparable by category within the Cahnos catalogue (same 5.0 mm size, other configurations): 843050 (Endosid Magill uncuffed with Murphy eye), 840050 (Endosid Magill uncuffed) and 845050 (5 mm emergency intubation kit). All are comparable at category level, not interchangeable 1:1. There is no manufacturer-validated equivalence table for this reference; consult the technical department before use in tenders.
5. Selection tips and variants of interest
Patient selection (usual clinical practice, not manufacturer specification): the 5.0 mm ID size is a common size in older paediatric patients and in adults with a narrow airway; as general guidance, sizes from 3.5 to 5.0 mm are used in children depending on age and weight, and from 7.0 to 9.0 mm in adults. The final choice must be based on the department’s protocol and anaesthetic assessment, always selecting the largest size compatible with the patient’s anatomy.
Cuff pressure: inflate via the pilot balloon with a syringe and maintain a sealing pressure of around 20-30 cmH2O (usual range in clinical practice) to minimise tracheal mucosal damage; monitor with a manometer if the department has one available. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen.
Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For prolonged ventilation with secretion drainage, consider the tube with subglottic suction lumen from the ETSL series; for procedures requiring kink resistance or frequent repositioning, the reinforced tubes in the intubation section (ETA…C02A2 series); and for oral, maxillofacial or ENT surgery where it is desirable to keep the circuit out of the surgical field, the preformed tubes from the ETPO/ETPN series. Contact the Cahnos technical department for the exact code for these variants in size 5.0 mm, as well as samples, volume conditions and hospital supply lead times.