Description
1. Introduction
The oral endotracheal tube with cuff and Murphy eye of 9.0 mm (ref. ETAN90C02) is a single-use airway management device, designed for orotracheal intubation of large adult patients in the operating theatre, intensive care units, emergency departments and resuscitation. Its sealing cuff configuration makes it the reference option when a tight and stable airway is required for positive pressure ventilation or general anaesthesia. It is presented in a box of 10 units with individual sterile packaging, ideal for the service stock and the intubation trolley.
2. Technical explanation of the device
The tube is inserted orally, passes through the glottis and is placed in the trachea, connecting at its proximal end to the ventilator, the anaesthesia circuit or the resuscitation bag via the universal 15 mm connector (conforming to ISO 5356-1). The cuff (pneumatic tamponade), once inflated through the pilot balloon, creates a hermetic seal against the tracheal wall that allows ventilation with positive pressure without significant leaks and reduces the risk of aspiration of gastric or pharyngeal contents. The Murphy eye, a distal lateral orifice, acts as an alternative ventilation pathway: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, the airflow continues. The radiopaque line and depth graduation facilitate clinical and radiological verification of position. It is a single-use device, not reusable.
3. Technical Specifications
| Reference | ETAN90C02 |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 9.0 mm |
| Configuration | With sealing cuff (pneumatic tamponade) |
| Murphy eye | Yes, distal lateral safety opening |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Connector | Universal 15 mm (ISO 5356-1) |
| Cuff inflation | Pilot balloon with one-way valve |
| Marking | Radiopaque line and depth graduation |
| Use | Single-use, non-reusable |
| Sterilisation | Ethylene oxide (EO), individual sterile packaging |
| Presentation | Box of 10 units |
| Indicative population | Large adult |
This 9.0 mm size is part of the ETAN range of oral endotracheal tubes with cuff and Murphy eye from Cahnos, available in several diameters to complete the service stock:
| Reference | ID (mm) |
| ETAN25C02 | 2.5 |
| ETAN30C02 | 3.0 |
| ETAN35C02 | 3.5 |
| ETAN40C02 | 4.0 |
| ETAN45C02 | 4.5 |
| ETAN50C02 | 5.0 |
| ETAN55C02 | 5.5 |
| ETAN60C02 | 6.0 |
| ETAN65C02 | 6.5 |
| ETAN70C02 | 7.0 |
| ETAN75C02 | 7.5 |
| ETAN80C02 | 8.0 |
| ETAN85C02 | 8.5 |
| ETAN90C02 (this product) | 9.0 |
| ETAN95C02 | 9.5 |
| ETAN10C02 | 10.0 |
4. Equivalences and Cross-References
The reference ETAN90C02 is a proprietary code of the Cahnos catalogue (nomenclature of the ETAN range of generic PVC tracheal tubes) and could not be compared with an official third-party manufacturer code in public sources: there is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tenders or in replacement of stock from other brands.
Comparable by category within the Cahnos catalogue (same 9.0 mm size, not 1:1 interchangeable):
| Reference | Description | Key difference |
| ETAN95C02 | Oral tube with cuff and Murphy eye ID 9.5 mm | Larger size in the same range |
| ETAN85C02 | Oral tube with cuff and Murphy eye ID 8.5 mm | Smaller size in the same range |
| ETSL90C02 | Oral tube with cuff, subglottic suction lumen and Murphy eye ID 9.0 mm | Adds subglottic suction (indicated in prolonged ventilation) |
| ETPO90C02 | Preformed oral tube (RAE) with balloon and Murphy eye ID 9.0 mm | Preformed curve for head and neck surgery |
| ETA090C02A2 | Reinforced oral tube with cuff and Murphy eye ID 9.0 mm | Adds helical anti-kink reinforcement |
| ETAM90C02A1 | Reinforced oral tube with cuff, guide and Murphy eye ID 9.0 mm | Includes insertion stylet and helical reinforcement |
| ETAN90002 | Oral tube without cuff and Murphy eye ID 9.0 mm | Without balloon; sealed by size contact |
At market level, oral endotracheal tubes with a 9.0 mm cuff fall into the same functional category as lines from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™), ICU Medical (Portex®) or Intersurgical: same general clinical indication, but it is essential to verify in each technical data sheet the internal diameter, material, presence of Murphy eye, type of cuff and sterilisation standard before replacing the device in a care protocol.
5. Selection tips and variants of interest
The 9.0 mm ID is reserved for large adult patients; as a general guide, in adults tubes of 7.0 to 9.0 mm are used depending on build and airway, always selecting the largest size compatible with the patient’s anatomy. Before intubation, check the integrity of the cuff and pilot balloon, completely deflate the balloon and inflate the minimum necessary to achieve an effective seal; the usual recommended cuff pressure on the market is 20–30 cmH₂O (usual use, verify the centre’s protocol). The cuff configuration is the appropriate option for prolonged positive pressure ventilation, general anaesthesia and situations requiring a tight seal and prevention of aspiration. If the procedure requires resistance to kinking or frequent repositioning, consider the reinforced variant (ETA090C02A2) or with guide (ETAM90C02A1); for prolonged ventilation with subglottic drainage, the ETSL range (ETSL90C02); and for oral, maxillofacial or head and neck surgery, the preformed (ETPO90C02). Complete the intubation trolley stock with the adjacent sizes of the range (ETAN85C02, ETAN95C02) and consult your technical-commercial delegate at Cahnos for volume conditions and hospital supply times.





Reviews