We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Oral Endotracheal Tube with Cuff and Murphy Eye – ID 9.0 mm | Medical Grade PVC, Single-use, Box of 10 (Ref. ETAN90C02)

16,05 €

Oral endotracheal tube with cuff and Murphy eye, with an internal diameter (ID) of 9.0 mm, made of medical-grade polyvinyl chloride (PVC), transparent, latex-free and single-use. Its sealing cuff guarantees a hermetic fit in the trachea during positive pressure ventilation and administration of anaesthesia, while the distal Murphy eye ensures the passage of air even if the tip becomes occluded. It incorporates a universal 15 mm connector (ISO 5356-1), pilot balloon and radiopaque line for position verification. Indicated for orotracheal intubation of large adult patients in the operating theatre, intensive care, emergency and resuscitation. Presentation in a box of 10 units with individual sterile packaging. Reference ETAN90C02.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN90C02

Description

1. Introduction

The oral endotracheal tube with cuff and Murphy eye of 9.0 mm (ref. ETAN90C02) is a single-use airway management device, designed for orotracheal intubation of large adult patients in the operating theatre, intensive care units, emergency departments and resuscitation. Its sealing cuff configuration makes it the reference option when a tight and stable airway is required for positive pressure ventilation or general anaesthesia. It is presented in a box of 10 units with individual sterile packaging, ideal for the service stock and the intubation trolley.

2. Technical explanation of the device

The tube is inserted orally, passes through the glottis and is placed in the trachea, connecting at its proximal end to the ventilator, the anaesthesia circuit or the resuscitation bag via the universal 15 mm connector (conforming to ISO 5356-1). The cuff (pneumatic tamponade), once inflated through the pilot balloon, creates a hermetic seal against the tracheal wall that allows ventilation with positive pressure without significant leaks and reduces the risk of aspiration of gastric or pharyngeal contents. The Murphy eye, a distal lateral orifice, acts as an alternative ventilation pathway: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, the airflow continues. The radiopaque line and depth graduation facilitate clinical and radiological verification of position. It is a single-use device, not reusable.

3. Technical Specifications

Reference ETAN90C02
Access route Oral (orotracheal)
Internal diameter (ID) 9.0 mm
Configuration With sealing cuff (pneumatic tamponade)
Murphy eye Yes, distal lateral safety opening
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Connector Universal 15 mm (ISO 5356-1)
Cuff inflation Pilot balloon with one-way valve
Marking Radiopaque line and depth graduation
Use Single-use, non-reusable
Sterilisation Ethylene oxide (EO), individual sterile packaging
Presentation Box of 10 units
Indicative population Large adult

This 9.0 mm size is part of the ETAN range of oral endotracheal tubes with cuff and Murphy eye from Cahnos, available in several diameters to complete the service stock:

Reference ID (mm)
ETAN25C02 2.5
ETAN30C02 3.0
ETAN35C02 3.5
ETAN40C02 4.0
ETAN45C02 4.5
ETAN50C02 5.0
ETAN55C02 5.5
ETAN60C02 6.0
ETAN65C02 6.5
ETAN70C02 7.0
ETAN75C02 7.5
ETAN80C02 8.0
ETAN85C02 8.5
ETAN90C02 (this product) 9.0
ETAN95C02 9.5
ETAN10C02 10.0

4. Equivalences and Cross-References

The reference ETAN90C02 is a proprietary code of the Cahnos catalogue (nomenclature of the ETAN range of generic PVC tracheal tubes) and could not be compared with an official third-party manufacturer code in public sources: there is no equivalence table validated by the manufacturer; consult the technical department of Cahnos before use in tenders or in replacement of stock from other brands.

Comparable by category within the Cahnos catalogue (same 9.0 mm size, not 1:1 interchangeable):

Reference Description Key difference
ETAN95C02 Oral tube with cuff and Murphy eye ID 9.5 mm Larger size in the same range
ETAN85C02 Oral tube with cuff and Murphy eye ID 8.5 mm Smaller size in the same range
ETSL90C02 Oral tube with cuff, subglottic suction lumen and Murphy eye ID 9.0 mm Adds subglottic suction (indicated in prolonged ventilation)
ETPO90C02 Preformed oral tube (RAE) with balloon and Murphy eye ID 9.0 mm Preformed curve for head and neck surgery
ETA090C02A2 Reinforced oral tube with cuff and Murphy eye ID 9.0 mm Adds helical anti-kink reinforcement
ETAM90C02A1 Reinforced oral tube with cuff, guide and Murphy eye ID 9.0 mm Includes insertion stylet and helical reinforcement
ETAN90002 Oral tube without cuff and Murphy eye ID 9.0 mm Without balloon; sealed by size contact

At market level, oral endotracheal tubes with a 9.0 mm cuff fall into the same functional category as lines from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™), ICU Medical (Portex®) or Intersurgical: same general clinical indication, but it is essential to verify in each technical data sheet the internal diameter, material, presence of Murphy eye, type of cuff and sterilisation standard before replacing the device in a care protocol.

5. Selection tips and variants of interest

The 9.0 mm ID is reserved for large adult patients; as a general guide, in adults tubes of 7.0 to 9.0 mm are used depending on build and airway, always selecting the largest size compatible with the patient’s anatomy. Before intubation, check the integrity of the cuff and pilot balloon, completely deflate the balloon and inflate the minimum necessary to achieve an effective seal; the usual recommended cuff pressure on the market is 20–30 cmH₂O (usual use, verify the centre’s protocol). The cuff configuration is the appropriate option for prolonged positive pressure ventilation, general anaesthesia and situations requiring a tight seal and prevention of aspiration. If the procedure requires resistance to kinking or frequent repositioning, consider the reinforced variant (ETA090C02A2) or with guide (ETAM90C02A1); for prolonged ventilation with subglottic drainage, the ETSL range (ETSL90C02); and for oral, maxillofacial or head and neck surgery, the preformed (ETPO90C02). Complete the intubation trolley stock with the adjacent sizes of the range (ETAN85C02, ETAN95C02) and consult your technical-commercial delegate at Cahnos for volume conditions and hospital supply times.

Additional information

Reference

ETAN90C02

Access route

Oral (orotracheal)

Inner diameter

9.0 mm

Configuration

With sealing cuff (pneumatic tamponade)

Murphy eye

Yes, distal lateral safety opening

Material

Medical-grade polyvinyl chloride (PVC), transparent, latex-free

Connector

Universal 15 mm (ISO 5356-1)

Cuff inflation

Pilot balloon with one-way valve

Marking

Radiopaque line and depth graduation

Use

Single-use, non-reusable

Sterilisation

Ethylene oxide (EO), individual sterile packaging

Presentation

Box of 10 units

Indicative population

Large adult

Reviews

There are no reviews yet.

Be the first to review “Oral Endotracheal Tube with Cuff and Murphy Eye – ID 9.0 mm | Medical Grade PVC, Single-use, Box of 10 (Ref. ETAN90C02)”

Your email address will not be published. Required fields are marked *