Description
1. Introduction
The uncuffed endotracheal tube (Ref. 57640) is the airway solution that anaesthesia, intensive care and emergency departments need to ensure positive-pressure ventilation and administration of anaesthesia when a ventilation face mask cannot be used. Manufactured in medical-grade PVC, sterile and single-use, it offers the controlled flexibility and biocompatibility required in critical procedures with small patients.
With a diameter of 3.0 mm and a length of 17.0 cm, it is especially indicated for intubation of neonates, infants and paediatric patients with a reduced-calibre airway. It is presented in a box of 100 units, a format designed for restocking NICUs, paediatric operating theatres, emergency bays and high-turnover intubation trolleys.
2. Technical explanation of the device
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, conducting gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. As it is an uncuffed tube, sealing is achieved by the anatomical fit of the calibre against the tracheal wall, a common practice in reduced-calibre airways and in patients in whom cuff inflation is contraindicated or unnecessary.
This model incorporates a bull-nose tip that facilitates atraumatic insertion, a crack-resistant radiopaque line for radiographic verification of position, a smooth Murphy eye as an alternative ventilation route if the main lumen becomes obstructed, and a temperature-sensitive, kink-resistant material that keeps the lumen patent throughout ventilation. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the data published in the manufacturer’s original catalogue for this reference:
| Manufacturer | GIMA |
|---|---|
| Reference | 57640 |
| Diameter | 3.0 mm |
| Tube length | 17.0 cm |
| Sleeve | Uncuffed |
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920199 |
Design features
- Bull-nose tip for atraumatic insertion.
- Crack-resistant radiopaque line (split-resistant).
- Smooth Murphy eye.
- Temperature-sensitive tube resistant to kinking (kink-resistant).
Note: verify the declaration of conformity, the CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
SKU 57640 is the manufacturer’s official reference for this 3.0 mm uncuffed endotracheal tube. To date, there is no equivalence table validated by the manufacturer for this reference; the following options are classified as comparable at category level (same product type and clinical indication, not interchangeable 1:1), checked against official sources:
| Manufacturer / line | Reference (ID 3.0 mm) |
|---|---|
| P. J. Dahlhausen – uncuffed Magill endotracheal tube, with Murphy eye, sterile | 44.000.11.030 |
| Teleflex (Rüsch® Safety Clear®) – uncuffed endotracheal tube, Murphy eye | 100382030 |
| Asid Bonz / Well Lead (ENDOSID®) – Magill tube without cuff with Murphy eye | 843030 |
These references share indication, calibre and general configuration, but may differ in the exact PVC compound, length, outer diameter, bevel geometry and Murphy eye design; they must be checked sheet by sheet against the manufacturer before any direct substitution in tenders. Consult the technical department of Cahnos before using them as equivalence in specifications or tenders.
5. Selection tips and variants of interest
Calibre selection: the 3.0 mm uncuffed diameter is intended for neonates, infants and small paediatric patients. As a general clinical practice guideline (not a manufacturer specification), calibres from 2.0 to 3.5 mm are used in premature infants and neonates. The final choice should be based on the department’s protocol and anaesthetic assessment (age, weight and estimated airway calibre).
Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the sterility expiry date. As it lacks a cuff, pay special attention to the fit of the tube in the trachea to minimise leaks and the risk of aspiration. Single-use product: do not re-sterilise or reuse.
Catalogue variants of interest: if you need another calibre, the Cahnos range of uncuffed endotracheal tubes covers diameters from 2.0 mm (e.g. Ref. ETAN20002) upwards. For procedures requiring an airtight seal or prolonged ventilation, consider the cuffed version of the same calibre; in the event of kinking risk or external compression, the reinforced uncuffed tube (Ref. ETA030002A2). Consult our technical-commercial team at Cahnos for reference approval, volume conditions and the configuration of the size stock most suitable for your department.




Reviews