Description
1. Commercial Introduction
The endotracheal tube with cuff in size Ø 5.0 mm is a single-use medical device, manufactured in polyvinyl chloride (PVC) and supplied in sterile packaging, designed to ensure a patent airway and reliable sealing during positive-pressure ventilation and administration of anaesthesia. It is the indicated solution for anaesthesia, intensive care and emergency services that need a resistant tube, with a high-volume, low-pressure cuff that protects the patient’s tracheal mucosa. Its presentation in a box of 100 units makes it a high-turnover format for intubation carts and hospital consumables.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The cuff, cylindrical or barrel-shaped, high volume and low pressure, is inflated via the pilot balloon and seals the tracheal lumen: it prevents gas leaks, prevents aspiration of secretions and stabilises the device during mechanical ventilation. The smooth Murphy eye, located in the distal zone, acts as a safety route: if the tip were to rest against the tracheal wall, respiratory flow continues through that opening and occlusion is never total. The break-resistant radiopaque line and the atraumatic rounded tip facilitate position verification and less traumatic insertion. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer reference | 57654 (SKU Cahnos: GM57654) |
| Manufacturer | GIMA |
| Tube diameter | 5.0 mm |
| Tube length | 24.5 cm |
| Material | Polyvinyl chloride (PVC), resistant and heat-sensitive walls |
| Cuff type | High volume, low pressure, cylindrical (barrel) shape, heat-sealed |
| Pilot balloon | Sensitive, quick response |
| Tip | Atraumatic rounded (bull-nose type) |
| Murphy eye | Present, smooth |
| Radiopaque line | Yes, resistant to breakage (split-resistant) |
| Sterilisation | Sterile, individual packaging |
| Use | Single-use (disposable) |
Product data
| Sales unit | Box of 100 units |
|---|---|
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920069 |
Key design features:
- Cylindrical high-volume, low-pressure cuffs.
- Sensitive pilot balloons with quick response.
- Finely heat-sealed cuffs.
- Atraumatic rounded tips (bull-nose).
- Break-resistant radiopaque lines.
- Smooth Murphy eyes.
- Heat-sensitive, kink-resistant tubes.
4. Equivalences and Cross-References
Reference 57654 corresponds to the manufacturer’s official catalogue (internal SKU Cahnos GM57654). There is no equivalence table validated by the manufacturer for this reference, so an exact 1:1 correspondence with other manufacturers cannot be declared. By clinical indication (cuffed endotracheal tube, size 5.0 mm), it is comparable at category level with the ETAN series tubes from the Cahnos catalogue (ETAN50C02, 5.0 mm, and adjacent sizes such as ETAN55C02, 5.5 mm), as well as with market lines from manufacturers such as Teleflex (Rüsch), Medtronic (Shiley) or ICU Medical (Portex). These brands do not publish an official equivalence table for this code and may differ in outer diameter, total length and cuff material; this must be checked sheet by sheet before replacing a specific product. Consult the Cahnos technical department before using it as an equivalence in tenders or bids.
5. Selection tips and variants of interest
- The Ø 5.0 mm cuffed size is intended for older paediatric patients, adolescents or adults with a reduced airway calibre; the final selection must be based on the anaesthetic assessment of each patient and on the service protocol.
- After inflation, keep the cuff pressure within the usual clinical range (ideally 20–30 cmH2O) with a manometer if the service has one, to minimise damage to the tracheal mucosa during prolonged ventilation.
- Before intubation, check the integrity of the tube, the patency of the Murphy eye and the correct condition of the cuff and pilot balloon.
- This tube is single-use: do not re-sterilise or reuse.
- If you need another size, consult the full range of cuffed and uncuffed endotracheal tubes available in the Cahnos catalogue, as well as the reinforced, guided or preformed variants for head and neck surgery.