Description
1. Commercial Introduction
The intrauterine insemination catheter PM-LIFE® IU CH5 with stylet (ref. PS2380545) is the ideal disposable and sterile solution for assisted reproduction clinics, gynaecology units and fertility laboratories performing intrauterine inseminations (IU). With CH5 calibre (1.6 mm), length of 175 mm and useful volume of 1.1 ml, this device combines a flexible body with a stylet-guided system, allowing stable, atraumatic insertion perfectly adapted to each patient’s anatomy. Each unit is supplied sterile in an individual package, latex-free, ensuring the highest biosafety conditions in the laboratory.
2. Technical explanation of the procedure
Intrauterine insemination consists of depositing a sample of washed, capacitated and prepared sperm directly into the uterine cavity at the optimal time of the ovulatory cycle. This catheter connects to a syringe or standard transfer system and advances through the cervical canal into the uterus. The included stylet allows the distal end to be pre-formed of the catheter, adapting its angulation to the patient’s uterine morphology and axis, minimising discomfort and trauma during cervical passage.
The centimetre graduations printed along the catheter body allow the clinician to control the insertion depth with total precision, optimising the effectiveness of the seminal deposit. The configuration of the distal orifices (1.1 mm) favours a uniform distribution of the sample in the uterine cavity. As a single-use, sterile, class Is device, the risk of cross-contamination between procedures is completely eliminated, ensuring traceability and patient safety in each cycle.
3. Technical Specifications
Data verified according to the manufacturer’s technical data sheet for reference PS2380545:
| Characteristic | Specification |
|---|---|
| Type | Intrauterine insemination catheter (IU) |
| Gauge | CH5 (5 French) |
| Diameter | 1.6 mm |
| Usable volume | 1.1 ml |
| Length | 175 mm |
| Hole diameter | 1.1 mm |
| Distal end length | 45 mm |
| Inserter (introducer) | No |
| Mandrel | Yes |
| Graduations | Centimetric |
| Single-use | Yes |
| Device class | Is |
| Sterile | Yes |
| Sterilisation method | Gamma radiation |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2002 |
| Presentation | Box of 25 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
4. Equivalences and Cross-References
This PM-LIFE® IU CH5 catheter with stylet belongs to the brand’s range of intrauterine insemination catheters, which complement each other according to calibre and guide system:
- PS4130500 – Mini CH5 catheter with stylet (Ø 1.65 mm, volume 1.1 ml): direct equivalent without introducer, of the same pre-forming concept.
- PS4160500 – CH5 catheter with introducer and stylet (Ø 1.65 mm, volume 1.1 ml): complete configuration with additional cervical guide.
- PS1270500 – Mini CH5 catheter with introducer (Ø 1.65 mm, volume 1.1 ml): without stylet.
- PS1260500 – Mini CH5 catheter without introducer or stylet (Ø 1.65 mm, volume 1.1 ml).
- PS4160600 – CH6 catheter with introducer and stylet (Ø 2 mm, volume 1.6 ml): same configuration in a larger calibre.
Due to its functional characteristics (diameter 1.6 mm, length 175 mm, tip with orifices and depth graduations) it falls into the same category as single-use cannulas and catheters for intrauterine insemination from other manufacturers on the European market, such as Frydman-type seminal transfer systems or the AINSEBLUE series cannulas (references 770113 and 770408). To confirm an exact equivalence with another manufacturer’s reference according to your protocol, contact our technical-commercial department.
5. Selection tips and variants of interest
To choose the most suitable catheter, assess the calibre of the cervical canal and the patient’s uterine morphology. This CH5 model with stylet (PS2380545) is the recommended option when the distal end needs to be pre-formed to adapt to anatomies with marked angulations, without the need for a cervical introducer. If an additional cervical guide is preferred, reference PS4160500 (CH5 with introducer and stylet) is the most complete option.
For narrower cervical canals or more sensitive patients, the mini CH5 range offers smaller-calibre alternatives; if greater flow of the seminal sample is required, the CH6 range (Ø 2 mm) with a larger useful volume is the recommended choice. All models share gamma radiation sterility, single-use, absence of latex and presentation in a box of 25 units. It is recommended to store the boxes in a cool, dry place and respect the expiry date of each individual sterile package. For volume orders or specific protocols for your centre, consult special conditions with our commercial team.