We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Elastomeric Infusion Pump ELASPUMP® Single-Use, Variable Flow Rate of 8 Speeds (0-2-4-6-8-10-12-14 ml/h), 100 ml, Free from DEHP | Ref. 093002/M3

40,50 €

Elastomeric infusion pump ELASPUMP® 100 ml single-use with variable flow rate of 8 speeds (0-2-4-6-8-10-12-14 ml/h). Designed for the administration of medications via intravenous, arterial, epidural and subcutaneous routes in chemotherapy, pain therapy, antiviral and antibiotic treatments. It operates without battery or maintenance: its silicone elastomer in a sealed housing drives the drug at a calibrated and selectable flow rate, with a one-way filling valve, hydrophobic filter on male luer-lock connector and in-line particle filter. Includes colour-coded labelling and printed flow rate for immediate identification. Free from DEHP, PVC and latex, sterile and biocompatible, eliminates the risk of cross-contamination. Ideal for hospitals, clinics and home hospitalisation, with a very competitive cost per treatment.

Pedido mínimo de 60 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
093002/M3

Description

1. Reliable elastomeric infusion without electronic equipment

The ELASPUMP® elastomeric infusion pump of 100 ml with variable flow of 8 speeds is the ideal solution for the administration of drugs in treatments requiring precise and safe dosing, without depending on batteries, electricity or maintenance. Designed for hospitals, clinics, home hospitalisation units and outpatient care centres, this single-use device offers a very competitive cost per treatment and eliminates the risk of cross-contamination between patients. Being manufactured free of phthalates (DEHP), without PVC and without latex, it is especially suitable for oncological therapies, pain therapy, antiviral treatments and antibiotics.

2. Technical description of the device

The ELASPUMP® pump consists of a silicone elastomer contained inside a hermetic, rigid and transparent housing that prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. Its operating principle is based on the elastic recovery pressure of the elastomer, which drives the drug through the tubular system at a constant and calibrated flow rate, selectable between 8 infusion speeds (0, 2, 4, 6, 8, 10, 12 and 14 ml/h) by means of a regulator integrated into the infusion line.

Its technical features include:

  • One-way closed-circuit filling valve with flat bottom, which facilitates loading of the elastomer using a standard syringe.
  • Hydrophobic filter on the male luer-lock connector cap, which allows priming of the tubular set once the elastomer has been filled without removing the cap, preserving internal sterility until actual use.
  • In-line particle filter, which retains impurities and guarantees the purity of the administered medication.
  • Removable sliding clamp, easy to remove if necessary.
  • Label with colour code and flow rate printing, for quick and immediate identification of the selected flow.
  • Patient label, for easy personalisation of the treatment.
  • Printing of all variable data and the product code on both the external housing and the pump body, ensuring complete traceability.

3. Technical Specifications

Characteristic Value
Capacity 100 ml
Flow type Variable with 8-speed selector
Infusion speeds 0 – 2 – 4 – 6 – 8 – 10 – 12 – 14 ml/h
Drive mechanism Silicone elastomer in rigid and transparent casing
Filling system Closed-circuit one-way valve, compatible with standard syringe
Connection Male Luer-lock with cap and hydrophobic filter
Filtration Hydrophobic filter + in-line particle filter
Routes of administration Intravenous, arterial, epidural and subcutaneous
Clinical indications Chemotherapy, pain therapy, antiviral and antibiotic treatments
Power supply Does not require battery or electrical power source
Use Single-use, sterile
Composition DEHP-free, PVC-free, latex-free
Brand ELASPUMP®
Reference 093002/M3

Indicative infusion duration (100 ml)

Selected flow rate Approximate duration
2 ml/h Approx. 2 days and 2 hours
4 ml/h Approx. 1 day and 1 hour
6 ml/h Approx. 16 hours and 40 minutes
8 ml/h Approx. 12 hours and 30 minutes
10 ml/h Approx. 10 hours
12 ml/h Approx. 8 hours and 20 minutes
14 ml/h Approx. 7 hours and 10 minutes

Indicative values calculated at full volume; the actual duration may vary slightly depending on the conditions of use and the characteristics of the drug.

4. Equivalences and Cross-References

The ELASPUMP® 100 ml variable flow (Ref. 093002/M3) belongs to the range of elastomeric pumps of the ELASPUMP® family and is complementary to the following references available at Cahnos:

  • 093004/M3: ELASPUMP® 200 ml variable flow with the same 8-speed selector (0-2-4-6-8-10-12-14 ml/h).
  • 093005/M3: ELASPUMP® 275 ml variable flow of 8 speeds (0-2-4-6-8-10-12-14 ml/h), for larger volumes.
  • 093005/M2: ELASPUMP® 275 ml variable flow with 8-speed selector (0-1-2-3-4-5-6-7 ml/h).
  • 093005/M1: ELASPUMP® 275 ml variable flow of 4 speeds (2-5-7-12 ml/h).
  • 093002/5/B: ELASPUMP® 100 ml continuous flow with UV protection (4 ml/h = 1 day + 1 hour).
  • 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/h = 1 day + 6 hours).
  • 093005/8/B: ELASPUMP® 275 ml continuous flow with UV protection (10 ml/h = 1 day + 3 hours).

Due to its 100 ml capacity, its pressurised elastomer system with luer-lock connector and flow regulator, this device is comparable to disposable elastomeric pumps with adjustable flow used in controlled analgesia and ambulatory infusion from other manufacturers (elastomer-type systems with flow dial), being interchangeable in most clinical protocols for continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.

5. Selection tips and variants of interest

  • Volume to infuse: the 100 ml version is ideal for short and medium duration therapies (from about 7 hours to 2 days depending on the selected flow rate). For smaller volumes, the 60 ml version is available, and for longer therapies, the 200 ml and 275 ml versions.
  • Required flow rate: if you need to adjust the speed during treatment or standardise different regimens, the variable flow model with 8 speeds (0-14 ml/h) offers maximum flexibility. If your protocol is fixed, the continuous flow versions may be more economical.
  • Photosensitive drugs: for light-sensitive medications, choose the ELASPUMP® versions with UV protection (Refs. 093002/5/B and 093005/8/B).
  • Accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.

Contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.

Additional information

Flow type

Variable with 8-speed selector (0-2-4-6-8-10-12-14 ml/h)

Drive mechanism

Silicone elastomer in rigid and transparent casing

Filling system

Closed-circuit one-way valve, compatible with standard syringe

Connection

Male Luer-lock with cap and hydrophobic filter

Filtration

Hydrophobic filter + in-line particle filter

Routes of administration

Intravenous, arterial, epidural and subcutaneous

Indications

Chemotherapy, pain therapy, antiviral and antibiotic treatments

Power supply

Does not require battery or electrical power source

Use

Single-use, sterile

Composition

DEHP-free, PVC-free, latex-free

Brand

ELASPUMP®

Reference

093002/M3

Capacidad

100 ml

Flujo por hora

8 Speeds (0-2-4-6-8-10-12-14)

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Elastomeric Infusion Pump ELASPUMP® Single-Use, Variable Flow Rate of 8 Speeds (0-2-4-6-8-10-12-14 ml/h), 100 ml, Free from DEHP | Ref. 093002/M3”

Your email address will not be published. Required fields are marked *