Description
1. Introduction
The SEG G18 1.3 × 45 mm-PUR Introcan Safety Braun Catheter (Ref. 4251679-01) is a peripheral intravenous safety catheter designed to provide reliable vascular access that is comfortable for the patient and especially safe for the healthcare professional. Its integrated passive protection system significantly reduces the risk of accidental needlestick injury during puncture and needle withdrawal, in line with current biological safety standards in healthcare settings.
2. Technical explanation
The Introcan Safety® is a single-use peripheral catheter that provides intravascular access for infusing fluids, administering medication and blood products, as well as for taking blood samples. It incorporates a fully automatic and passive safety mechanism: when the metal stylet is withdrawn, a safety clip deploys to cover the needle tip without requiring any additional action from the professional, eliminating the human factor in the activation of the protection.
The catheter is made of polyurethane (PUR), a material that provides flexibility, tensile strength and good vascular tolerance, allowing a more comfortable dwell time in the vein and a stable flow. The female Luer-Lock connection ensures a tight fit with three-way stopcocks, extension lines and infusion sets, preventing accidental disconnections during treatment.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Manufacturer reference | 4251679-01 (Introcan Safety® PUR 18G, 1.3 × 45 mm, EU version) |
| Gauge (gauge) | 18G |
| Catheter outer diameter | 1.30 mm |
| Catheter inner diameter | 1.00 mm |
| Catheter length | 45 mm (1¾ inches) |
| Catheter material | Polyurethane (PUR) |
| Connection | Female Luer-Lock |
| Maximum flow rate | 100 ml/min |
| Residual volume | 0.125 ml |
| Colour code | Green (standard 18G identification) |
| Wings | No (straight catheter, without wings) |
| Injection port | No |
| Safety system | Automatic passive anti-needlestick safety clip |
| Use | Single-use, sterile |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references this product with products from other brands; consult the technical department before use in tenders. Verification against the official B. Braun catalogue confirms code 4251679-01 as Introcan Safety® PUR 18G, 1.3 × 45 mm, without wings and without injection port, with a flow rate of 100 ml/min and female Luer-Lock connector.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun | Introcan Safety® with wings | 4253590-01 | Comparable by category (not interchangeable 1:1) | Same gauge (G18), length (45 mm) and material (PUR), but includes fixation wings; the product analysed is straight, without wings. |
| B. Braun | Vasofix Safety® PUR | 4269136S-01 | Comparable by category (not interchangeable 1:1) | Same gauge (G18), length (45 mm) and material (PUR); includes wings and injection port, compared to the straight model without port of this reference. |
As for other brands, passive protection safety catheters such as Nipro SafeTouch® cover the same clinical indication, but their 18G variants are offered in lengths of 32 mm and 50 mm (not 45 mm), so they are considered comparable at category level and not interchangeable 1:1. Before any substitution, verify in the candidate’s technical data sheet the material, gauge, length, connector and the presence of wings or injection port.
5. Selection tips and variants of interest
The 18G (green) gauge is the usual choice for blood product transfusions, rapid volume administration and higher-viscosity drugs in adult patients. For higher flows or larger-gauge access, consider the 16G (1.7 × 50 mm) and 14G (2.2 × 50 mm) versions; for paediatrics or small-calibre veins, the 20G (1.1 × 32 mm), 22G (0.9 × 25 mm) and 24G (0.7 × 19 mm) versions.
If the protocol requires fixation with wings or additional medication administration without puncturing the system, consult the variants with wings and injection port from the same family. Always check the batch and sterility date upon receipt: the product is single-use and must not be re-sterilised.





Reviews