Description
1. Commercial Introduction
The Elastomeric Infusion Pump ELASPUMP® 60 ml with UV protection (Ref. 093001/5/B) is the ideal solution for the continuous and controlled administration of medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free of DEHP, PVC and latex, which allows drugs to be infused at a calibrated flow rate of 4 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment and no risk of cross-contamination between patients.
Its UV-protected design makes it especially recommended for photosensitive medications, common in oncology treatments, and its ease of use makes it a practical option for both healthcare professionals and patients themselves, with an approximate autonomy of 15 hours at full volume, ideal for short-to-medium duration infusion regimens and outpatient therapy.
2. Technical description and operating principle
The ELASPUMP® pump operates through the elastic recovery pressure of a silicone elastomer housed inside a hermetic, rigid and transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. This pressure drives the medication through the tubular system at a constant, factory-calibrated flow rate of 4 ml/hour, resulting in an approximate autonomy of 0 days + 15 hours with the full 60 ml volume. The integrated UV protection preserves drug stability throughout the infusion period.
- Silicone elastomer: encapsulated in a hermetic, rigid and transparent casing with UV protection, leak-free and with visual level inspection.
- One-way filling valve: closed-circuit with flat bottom, compatible with a standard syringe, which facilitates elastomer filling.
- Hydrophobic filter: on the male luer-lock connector cap; allows priming the line without removing the cap and preserves internal sterility until actual use.
- In-line particle filter: retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp: easy to remove when necessary.
- Colour-coded label: with flow rate printed for quick and immediate identification of the flow.
- Patient label: designed for easy personalisation of the treatment.
- Full traceability: variable data and product code printed on the outer casing and on the pump body.
3. Technical Specifications
The main technical specifications of the ELASPUMP® 60 ml pump with UV protection and continuous flow at 4 ml/hour are detailed below:
| Characteristic | Specification |
| Brand | ELASPUMP® |
| Reference | 093001/5/B |
| Capacity | 60 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 4 ml/hora |
| Approximate duration | 0 days + 15 hours (approx. 15 hours at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-Lock connector with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Protection | UV protection for photosensitive drugs |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
Indicative duration of the ELASPUMP® continuous flow range with UV protection at 4 ml/hour:
| Reference | Capacity | Flow rate | Approximate duration |
| 093001/5/B (current product) | 60 ml | 4 ml/hora | 0 days + 15 hours |
| 093002/5/B | 100 ml | 4 ml/hora | 1 day + 1 hour |
| 093004/5/B | 200 ml | 4 ml/hora | 2 days + 2 hours |
| 093005/5/B | 275 ml | 4 ml/hora | 2 days + 21 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.
4. Equivalences and Cross-References
The ELASPUMP® 60 ml with UV protection (Ref. 093001/5/B) belongs to the range of continuous-flow elastomeric pumps with UV protection from the ELASPUMP® family and is complementary to the following references available at Cahnos:
- 093001/6/B: ELASPUMP® 60 ml with UV protection, continuous flow of 5 ml/hour (0 days + 12 hours), same capacity with a slightly higher flow rate.
- 093001/8/B: ELASPUMP® 60 ml with UV protection, continuous flow of 10 ml/hour (0 days + 6 hours), same capacity for faster infusions.
- 093002/5/B: ELASPUMP® 100 ml with UV protection, continuous flow of 4 ml/hour (1 day + 1 hour), same flow rate with larger volume.
- 093004/5/B: ELASPUMP® 200 ml with UV protection, continuous flow of 4 ml/hour (2 days + 2 hours), same flow rate with larger volume.
- 093005/5/B: ELASPUMP® 275 ml with UV protection, continuous flow of 4 ml/hour (2 days + 21 hours), for longer therapies.
- 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour = 1 day + 6 hours), same capacity without UV protection.
- 093001/M1 · M2 · M3: ELASPUMP® 60 ml variable flow, DEHP-free, for protocols with adjustable flow rate.
Due to its 60 ml capacity, pressurised elastomer system with luer-lock connector, hydrophobic filter, fixed calibrated flow rate and UV protection, this device is comparable to disposable continuous-flow elastomeric pumps from other manufacturers used in outpatient infusion, controlled analgesia and home intravenous therapy, and is interchangeable in most clinical protocols for continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.
5. Selection tips and variants of interest
- Volume and duration: the 60 ml version at 4 ml/hour is ideal for therapies of approximately 15 hours at full volume. For longer regimens with the same flow rate, versions of 100 ml (Ref. 093002/5/B), 200 ml (Ref. 093004/5/B) and 275 ml (Ref. 093005/5/B) are available.
- Required flow rate: if your protocol is fixed, this continuous-flow version at 4 ml/hour offers an excellent balance between duration and cost per treatment. If you need to adjust the speed during treatment, consider the variable-flow versions of 60 ml (Refs. 093001/M1, M2 and M3).
- Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093001/5/B, 093001/6/B, 093001/8/B, 093002/5/B, 093004/5/B and 093005/5/B).
- Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
- Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.