Description
1. Continuous, safe infusion without electronic equipment
The ELASPUMP® 60 ml Elastomeric Infusion Pump with UV protection (Ref. 093001/1/B) is the ideal solution for the continuous and controlled administration of medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free of DEHP, PVC and latex, which allows drugs to be infused at a calibrated flow rate of 0.5 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment and no risk of cross-contamination between patients.
Its UV protection design makes it especially recommended for photosensitive medications, common in oncology treatments, and its minimally invasive flow rate of 0.5 ml/hour offers the greatest autonomy of the entire 60 ml range: approximately 5 days at full volume. Its ease of use makes it a practical option for both healthcare professionals and patients themselves in slow, prolonged infusion regimens and ambulatory therapy.
2. Technical description and operating principle
The ELASPUMP® pump works through the elastic recovery pressure of a silicone elastomer housed inside a hermetic, rigid and transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. This pressure drives the medication through the tubular system at a constant, factory-calibrated flow rate of 0.5 ml/hour, resulting in an approximate autonomy of 5 days + 0 hours (120 hours) with the full 60 ml volume. The integrated UV protection preserves the stability of the drug throughout the infusion period.
- Silicone elastomer: encapsulated in a hermetic, rigid and transparent casing with UV protection, leak-free and with visual level inspection.
- One-way filling valve: closed-circuit with flat bottom, compatible with a standard syringe, facilitating elastomer loading.
- Hydrophobic filter: on the male luer-lock connector cap; allows priming the line without removing the cap and preserves internal sterility until actual use.
- In-line particle filter: retains impurities and ensures the purity of the administered drug.
- Removable sliding clamp: easy to remove when necessary.
- Colour-coded label: with flow rate printed for quick and immediate flow identification.
- Patient label: designed for easy treatment personalisation.
- Full traceability: variable data and product code printed on the external casing and on the pump body.
3. Technical Specifications
The main technical specifications of the ELASPUMP® 60 ml pump with UV protection and continuous flow at 0.5 ml/hour are detailed below:
| Characteristic | Specification |
|---|---|
| Brand | ELASPUMP® |
| Reference | 093001/1/B |
| Capacity | 60 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 0.5 ml/hora |
| Approximate duration | 5 days + 0 hours (approx. 120 hours at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-Lock connector with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Protection | UV protection for photosensitive drugs |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
Indicative infusion duration according to flow rate (60 ml volume):
| Flow rate | Approximate duration |
|---|---|
| 0.5 ml/hour (current product) | 5 days + 0 hours (approx. 120 hours) |
| 1 ml/hora | 2 days + 12 hours (approx. 60 hours) |
| 1.5 ml/hora | 1 day + 16 hours (approx. 40 hours) |
| 2 ml/hora | 1 day + 6 hours (approx. 30 hours) |
| 2.5 ml/hora | 1 day + 0 hours (approx. 24 hours) |
| 4 ml/hora | 0 days + 15 hours (approx. 15 hours) |
| 5 ml/hora | 0 days + 12 hours (approx. 12 hours) |
| 10 ml/hora | 0 days + 6 hours (approx. 6 hours) |
ELASPUMP® continuous flow range with UV protection in 60 ml available at Cahnos:
| Reference | Capacity | Flow rate | Approximate duration |
|---|---|---|---|
| 093001/1/B (current product) | 60 ml | 0.5 ml/hora | 5 days + 0 hours |
| 093001/2/B | 60 ml | 1 ml/hora | 2 days + 12 hours |
| 093001/3/B | 60 ml | 1.5 ml/hora | 1 day + 16 hours |
| 093001/4/B | 60 ml | 2 ml/hora | 1 day + 6 hours |
| 093001/41/B | 60 ml | 2.5 ml/hora | 1 day + 0 hours |
| 093001/5/B | 60 ml | 4 ml/hora | 0 days + 15 hours |
| 093001/6/B | 60 ml | 5 ml/hora | 0 days + 12 hours |
| 093001/8/B | 60 ml | 10 ml/hora | 0 days + 6 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.
4. Equivalences and Cross-References
The ELASPUMP® 60 ml with UV protection (Ref. 093001/1/B) belongs to the range of continuous flow elastomeric pumps with UV protection from the ELASPUMP® family and is complementary to the following references available at Cahnos:
- 093002/1/B: ELASPUMP® 100 ml with UV protection, same flow rate of 0.5 ml/hour (8 days + 8 hours), same speed with larger volume for even longer therapies.
- 093001/2/B: ELASPUMP® 60 ml with UV protection, 1 ml/hour (2 days + 12 hours), same capacity with higher flow rate.
- 093001/3/B: ELASPUMP® 60 ml with UV protection, 1.5 ml/hour (1 day + 16 hours).
- 093001/4/B: ELASPUMP® 60 ml with UV protection, 2 ml/hour (1 day + 6 hours).
- 093001/41/B: ELASPUMP® 60 ml with UV protection, 2.5 ml/hour (1 day + 0 hours).
- 093001/5/B, 093001/6/B and 093001/8/B: 60 ml versions with UV protection at 4, 5 and 10 ml/hour for shorter-duration regimens.
- 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour = 1 day + 6 hours), same capacity without UV protection.
- 093001/M1 · M2 · M3: ELASPUMP® 60 ml variable flow, DEHP-free, for protocols with adjustable flow rate.
Due to its 60 ml capacity, pressurised elastomer system with luer-lock connector, hydrophobic filter, fixed calibrated flow rate and UV protection, this device is comparable to disposable continuous flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most clinical protocols for low-speed continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.
5. Selection tips and variants of interest
- Volume and duration: the 60 ml version at 0.5 ml/hour offers the greatest autonomy in the 60 ml range, ideal for prolonged therapies of approximately 120 hours (5 days) at full volume, very useful in very slow, continuous and long-duration ambulatory infusion regimens.
- Required flow rate: if your protocol is fixed and very low flow, this version at 0.5 ml/hour offers the best cost-benefit ratio. If you need more speed, consider references 093001/2/B, 093001/3/B, 093001/4/B, 093001/41/B, 093001/5/B, 093001/6/B and 093001/8/B.
- Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093001/1/B, 093001/2/B, 093001/3/B, 093001/4/B, 093001/41/B, 093001/5/B, 093001/6/B, 093001/8/B and 093002/1/B, among others).
- Longer therapies: for longer durations with the same flow rate of 0.5 ml/hour, the 100 ml version is available (Ref. 093002/1/B). If you need to adjust the speed during treatment, consider the variable flow versions of 60 ml (Refs. 093001/M1, M2 and M3).
- Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
- Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.