Description
1. Continuous, safe infusion without electronic equipment
The ELASPUMP® 100 ml elastomeric infusion pump with UV protection (Ref. 093002/2/B) is the ideal solution for the constant and controlled administration of medication in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free from DEHP, PVC and latex, which allows drugs to be infused at a calibrated flow rate of 1 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment and no risk of cross-contamination between patients. Its UV protection design makes it especially recommended for photosensitive drugs, common in oncology treatments and prolonged infusion regimens.
2. Technical description and operating principle
The ELASPUMP® pump works through the elastic recovery pressure of a silicone elastomer contained inside a hermetic, rigid and transparent housing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. This pressure drives the medication through the tubular system at a constant flow rate calibrated at the factory of 1 ml/hour, resulting in an approximate autonomy of 4 days + 4 hours (100 hours) with the full 100 ml volume. The integrated UV protection preserves the stability of the drug throughout the infusion period.
- Silicone elastomer: encapsulated in a hermetic, rigid and transparent housing with UV protection, leak-free and with visual level inspection.
- One-way filling valve: closed-circuit with flat bottom, compatible with standard syringe.
- Hydrophobic filter: on the male luer-lock connector cap; allows priming of the line without removing the cap and preserves internal sterility until actual use.
- In-line particle filter: retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp: easy to remove when necessary.
- Colour-coded label: flow rate printed for quick and immediate identification of the flow.
- Patient label: designed for easy personalisation of the treatment.
- Full traceability: variable data and product code printed on the external housing and on the pump body.
3. Technical Specifications
| Characteristic | Specification |
| Brand | ELASPUMP® |
| Reference | 093002/2/B |
| Capacity | 100 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 1 ml/hora |
| Approximate duration | 4 days + 4 hours (approx. 100 hours at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-lock with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Protection | UV protection for photosensitive drugs |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
Indicative infusion duration by flow rate (100 ml volume):
| Flow rate | Approximate duration |
| 1 ml/hour (current product) | 4 days + 4 hours (approx. 100 hours) |
| 1.5 ml/hora | 2 days + 19 hours (approx. 67 hours) |
| 2.5 ml/hora | 1 day + 16 hours (approx. 40 hours) |
| 4 ml/hora | 1 day + 1 hour (approx. 25 hours) |
| 5 ml/hora | 0 days + 20 hours |
| 8 ml/hora | 0 days + 12 hours |
| 10 ml/hora | 0 days + 10 hours |
ELASPUMP® continuous flow range with UV protection available at Cahnos:
| Reference | Capacity | Flow rate | Approximate duration |
| 093002/2/B (current product) | 100 ml | 1 ml/hora | 4 days + 4 hours |
| 093002/3/B | 100 ml | 1.5 ml/hora | 2 days + 19 hours |
| 093002/41/B | 100 ml | 2.5 ml/hora | 1 day + 16 hours |
| 093002/5/B | 100 ml | 4 ml/hora | 1 day + 1 hour |
| 093002/6/B | 100 ml | 5 ml/hora | 0 days + 20 hours |
| 093002/7/B | 100 ml | 8 ml/hora | 0 days + 12 hours |
| 093002/8/B | 100 ml | 10 ml/hora | 0 days + 10 hours |
| 093004/2/B | 200 ml | 1 ml/hora | 8 days + 8 hours |
| 093004/4/B | 200 ml | 2 ml/hora | 4 days + 4 hours |
| 093005/2/B | 275 ml | 1 ml/hora | 11 days + 11 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.
4. Equivalences and Cross-References
The ELASPUMP® 100 ml with UV protection (Ref. 093002/2/B) belongs to the range of continuous flow elastomeric pumps of the ELASPUMP® family and is complementary to the following references available at Cahnos:
- 093004/2/B: ELASPUMP® 200 ml with UV protection, same flow rate of 1 ml/hour (8 days + 8 hours), for larger volume.
- 093005/2/B: ELASPUMP® 275 ml with UV protection, same flow rate of 1 ml/hour (11 days + 11 hours), for very long-duration therapies.
- 093002/3/B, 093002/41/B, 093002/5/B, 093002/6/B, 093002/7/B and 093002/8/B: 100 ml versions with UV protection at higher flow rates (1.5 to 10 ml/hour).
- 093004/4/B and 093004/41/B: 200 ml versions with UV protection (2 and 2.5 ml/hour).
- 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour = 1 day + 6 hours), for smaller volumes.
- 093002/M1, 093002/M2 and 093002/M3: 100 ml variable flow versions, free from DEHP, for protocols with adjustable flow rate.
Due to its 100 ml capacity, its pressurised elastomer system with luer-lock connector, hydrophobic filter, fixed calibrated flow rate and UV protection, this device is comparable to disposable continuous flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most clinical protocols for low-rate continuous infusion. Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.
5. Selection tips and variants of interest
- Volume and duration: the 100 ml version at 1 ml/hour is ideal for prolonged therapies of approximately 4 days and 4 hours, very useful in multi-day outpatient regimens. For smaller volumes, the 60 ml version (Ref. 093001/4) is available, and for even longer therapies, the 200 ml and 275 ml versions with UV protection (Refs. 093004/2/B and 093005/2/B).
- Required flow rate: the 1 ml/hour model is the lowest flow rate in the 100 ml range, designed for slow and prolonged regimens. If your protocol requires a higher speed, consider the continuous flow versions from 1.5 to 10 ml/hour or the 100 ml variable flow versions (Refs. 093002/M1, M2 and M3).
- Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093002/2/B, 093002/3/B, 093002/5/B, 093004/2/B, 093004/4/B and 093005/2/B, among others).
- Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
- Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.




Reviews