BabyGuard I-1120 incubator by Dixion for neonatal intensive care
1. Introduction
The BabyGuard I-1120 is the reference closed incubator in the Dixion series for neonatal intensive care units. Designed for the most vulnerable patients, it provides a thermal, humidified and, optionally, controlled oxygen concentration environment, all managed by a microcomputer that ensures exceptional clinical stability. It is the professional choice for hospitals and clinics seeking reliable neonatal technology, a clear interface for the clinician and a robust, functional design for day-to-day NICU use.
2. Technical explanation and operation
The BabyGuard I-1120 incorporates a microcomputer servo-control that independently regulates air temperature, baby skin temperature and air humidity, with a special air circulation system that minimises flow inside the hood and prevents draughts over the neonate. The automatic curtain reduces heat loss on each opening, and the double-walled hood retains heat for 2 hours even without power, a critical safety factor. In optional configuration, the unit incorporates servo-control of oxygen concentration (control range 20–60 % and measurement 0–99 %) for neonatal respiratory support. Its large LCD screen displays real skin and air temperature, set temperature and heater output, with graphical trends of up to 48 hours that allow the clinician to assess the evolution of the environment at a glance. The system features up to 9 configurable alarms (power failure, airflow failure, sensor failure, deviation, overtemperature, high/low humidity, high/low oxygen), RS-232 interface for remote control and monitoring, vertical height adjustment support, X-ray cassette and optional scale.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Set type | Closed incubator for neonatal intensive care |
| Control system | Microcomputer servo-control of air temperature, skin temperature and air humidity |
| Air temperature control range | 25–37 °C (override mode: 37–39 °C) |
| Skin temperature control range | 34–37 °C (override mode: 37–38 °C) |
| Temperature rise time | 40 minutes |
| Humidity control range | 0–90 % |
| Water container capacity | 1–2 litres (up to 12 hours of service per container) |
| Oxygen concentration (optional) | Measurement range 0–99 %; control range 20–60 % |
| Bassinet tilt | ±8° |
| Air flow inside the hood | < 0.2 m/s |
| Noise level inside the hood | < 45 dB |
| Display | Large LCD: real skin and air temperature, set temperature, heater output and graphical trends of up to 48 hours |
| Alarms | Option of 9 alarms: power failure, airflow failure, air and skin temperature sensor failure, sensor deviation, high-temperature sensor failure, high/low skin temperature, high/low humidity, high/low oxygen concentration |
| Interface | RS-232 for remote control |
| Power supply | 220–230 V, 50–60 Hz |
| Dimensions (W x H x D) | 675 x 1650 x 1500 mm (675 x 1800 x 1500 mm with vertical height adjustment support) |
Standard equipment and accessories: double-walled hood with side windows with transparent panels and flexible sleeves, front window with iris diaphragm, automatic curtain, smooth mattress tray adjustment, X-ray film cassette, film control keypad, basic trolley on castors with brakes, 3 drawers for belongings, shelves for additional equipment, IV pole. Optional: built-in scale, oxygen servo-control and vertical height adjustment support.
4. Equivalences and Cross-References
The BabyGuard I-1120 belongs to the Dixion family of closed intensive care incubators, together with the Cahnos catalogue references I-1103 (passive humidification without oxygen control), I-1107 (humidity and oxygen control) and I-1125 (transport version with AC/DC power and battery). As an open resuscitation system, Dixion also offers the radiant warmers W-1140, W-1140-02 and W-1145 for delivery and resuscitation rooms. In the clinical concept, the I-1120 competes directly with closed incubators from other international manufacturers such as Dräger (Isolette/Babytherm series), GE Healthcare, Fanem or Atom Medical, being functionally interchangeable in its role of thermal support, humidity control and oxygen administration in neonatal intensive care. For budgets and tenders, the technical-commercial department of Cahnos can provide you with a detailed comparison with the reference your centre currently uses.
5. Selection tips and variants of interest
Assess the type of care your unit provides: if you care for stable neonates requiring a closed environment with humidity control and, occasionally, oxygen, the I-1120 is the most complete option in the closed series thanks to its humidity servo-control and the oxygen concentration control option. If your centre performs transfers, consider the I-1125 with battery and AC/DC power; if you need an open resuscitation system for delivery rooms, consider the references W-1140, W-1140-02 or W-1145. Complete the equipment with the gel positioners for the incubator tray available at Cahnos (ref. GBSK0022-PS and GBSK0023-PS) and always check electrical compatibility (220–230 V / 50–60 Hz) and the space available in the room. For institutional purchases, supply lead times or tender requirements, consult your technical-commercial advisor at Cahnos.