FLIR identiFINDER R425 | Portable gamma and neutron radionuclide detector and identifier for Nuclear Medicine and Radiology

Price on request

FLIR identiFINDER R425, the world’s most widely deployed new-generation radionuclide identification device (RID), with 360º coverage to locate and measure gamma and neutron radioactive sources with total confidence. It incorporates a cubic NaI(Tl) detector with silicon photomultiplier, energy range from 20 keV to 3 MeV, resolution ≤7 % FWHM at 662 keV, Geiger-Müller tube for high dose rates (up to 10 Sv/h) and option of higher-resolution LaBr₃(Ce) detector (≤3.5 %). Robust, IP67, with screen readable in full sunlight, battery life of up to 12 hours and cold start in less than 20 seconds. Ideal for Nuclear Medicine, Radiology, radiation protection and radiological surveillance services.

International shipping. Import duties and taxes are payable by the recipient.

Reference
CAH-FLIR IDENT R 425

Description

1. Introduction

The FLIR identiFINDER R425 is the natural evolution of the most widely used radionuclide identification device (RID) in the world, with more than 25,000 units deployed. Designed for the measurement and localisation of gamma and neutron radioactive sources, it offers 360-degree coverage thanks to its cubic detector, allowing healthcare professionals to locate, measure and identify the radioactive source from any orientation and with total safety. It is the ideal companion for Nuclear Medicine and Radiology services, as well as for radiation protection teams, emergency care and environmental radiological surveillance.

2. Technical explanation of the equipment

The identiFINDER R425 combines a cubic NaI(Tl) scintillation detector (45 × 45 × 45 mm) coupled to a silicon photomultiplier (SiPM), providing excellent directional response in all directions and gamma sensitivity up to 3 times higher than the previous generation. In models with neutron detection (GN/LGN), it incorporates moderated zinc sulfide (ZnS) panels with twice the neutron sensitivity. The device performs 1024-channel gamma spectroscopy, automatic radionuclide identification in accordance with ANSI N42.34 and classification into the SNM, IND, MED and NORM categories.

Its energy-compensated Geiger-Müller tube extends the dose rate measurement capability up to 1000 R/h (10 Sv/h), so the device remains fully operational and accurate even in extremely high gamma fields where other systems fail. It incorporates source-free gain stabilisation, real-time linearisation of gamma energy, a 3-button interface inherited from the identiFINDER R400, a sunlight-readable display visible with polarised sunglasses, 8 GB internal memory, dual USB-C port, Bluetooth BLE 5.0 and integrated GPS for recording and remote communication of results.

3. Technical Specifications

Parameter Value
Technology Radionuclide identification device (RID); gamma and gamma/neutron models
Gamma detector Cubic NaI(Tl) 45 × 45 × 45 mm with silicon photomultiplier (SiPM)
Optional gamma detector Cubic LaBr₃(Ce) 35 × 35 × 35 mm with SiPM (LG/LNG models)
High dose rate detector Energy-compensated Geiger-Müller tube (up to 1000 R/h / 10 Sv/h)
Neutron detector 2 moderated ZnS panels of 27 × 58 × 5 mm (GN/LGN models)
Energy range (gamma) 20 keV – 3 MeV
Gamma sensitivity (Cs-137) 1610 cps/µSv/h (G/GN models); 1000 cps/µSv/h (LG/LGN models)
Neutron sensitivity ≥ 15 cps/nv (GN/LGN models)
Gamma spectrum 1024 channels
Dose rate range (Cs-137) 100 nSv/h – 10 mSv/h ± 10 %
High dose rate range 10 mSv/h – 1 Sv/h ± 30 %
Energy resolution ≤ 7 % FWHM at 662 keV (G/GN models); ≤ 3.5 % FWHM (LG/LGN models)
Stabilisation Source-free gain stabilisation; real-time linearisation
Identification According to ANSI N42.34; SNM, IND, MED, NORM categories
Display 2.7″ diagonal (400 × 240 pixels), readable in full sunlight and with polarised sunglasses
Connectivity 2 × USB-C, Bluetooth BLE 5.0, integrated GPS, integrated web server
Storage 8 GB internal; data format according to ANSI N42.42
Power supply Internal Li-ion up to 12 h; external 16650 Li-ion batteries or 2 × CR123 hot-swappable
Cold start ≤ 20 seconds
Operating temperature −30 °C to +60 °C; humidity 0 – 100 %
Protection IP67 according to IEC 60529; compliant with MIL-STD 810G (salt/fog)
Dimensions 235 × 100 × 95 mm
Weight ≤ 1.2 kg
Maintenance Recommended service interval of 5 years

4. Equivalences and Cross-References

The FLIR identiFINDER R425 is the direct successor to the identiFINDER R400, keeping the same 3-button user interface and its identification algorithms, with 15 % less weight and superior performance. Within the same family, the R425 G (gamma), R425 GN (gamma/neutron), R425 LG and R425 LGN variants are marketed (with high-resolution LaBr₃ detector), as well as the underwater version identiFINDER R425 UW, resistant to 20 metres depth and with MIL-STD 810G certification (salt/fog). In the Cahnos catalogue, this equipment can be complemented with the type 44A radiation meter (ref. CAH-RM0000), intended for scanning large contaminated areas using a sodium iodide scintillation probe in Nuclear Medicine services.

5. Selection tips and variants of interest

Select the identiFINDER R425 when your department needs to locate, measure and identify radionuclides in a single portable device, with spectral capability and operation in high-radiation fields. For combined detection of neutron sources (special nuclear materials), choose the GN version. If you prioritise maximum energy resolution to separate close photopeaks, opt for the variant with LaBr₃ detector. For operations in wet or submerged environments, the UW version is the most suitable. The equipment is delivered with the FLIR web interface for remote viewing and operation, connectivity with the FLIR RAD mobile app and universal API for integration into surveillance networks. Consult our commercial team at Cahnos to confirm availability, configuration and training and commissioning options according to the needs of your centre.

Additional information

Product type

Portable radionuclide identification device (RID)

Detection

Gamma and neutrons (GN/LGN models)

Gamma detector

Cubic NaI(Tl) 45×45×45 mm with SiPM; LaBr₃(Ce) 35×35×35 mm option

High rate detector

Energy-compensated Geiger-Müller tube up to 1000 R/h (10 Sv/h)

Neutron detector

2 moderated ZnS panels (27×58×5 mm)

Gamma energy range

20 keV – 3 MeV

Spectrum channels

1024 channels

Energy resolution

≤ 7 % FWHM at 662 keV (≤ 3.5 % with LaBr₃)

Gamma sensitivity

1610 cps/µSv/h (Cs-137)

Neutron sensitivity

≥ 15 cps/nv

Dose rate range

100 nSv/h – 10 mSv/h ±10 %; high rate 10 mSv/h – 1 Sv/h ±30 %

Nuclide identification

ANSI N42.34; SNM, IND, MED, NORM categories

Display

2.7" (400×240 pixels), readable in full sunlight

Connectivity

2× USB-C, Bluetooth BLE 5.0, integrated GPS, web server

Storage

8 GB internal

Battery

Internal Li-ion up to 12 h; external 16650 Li-ion or 2× CR123 hot-swappable

Cold start

≤ 20 seconds

Operating temperature

−30 °C to +60 °C

Protection

IP67 (IEC 60529); MIL-STD 810G salt/fog

Dimensions

235 × 100 × 95 mm

Weight

≤ 1.2 kg

Regulatory standard

ANSI N42.34, ANSI N42.42, IEC 60529

Maintenance

5-year service interval