Description
Rapid hepatitis C test: reliable serological screening at the point of care
The Hepatitis C HCV-Test Hep C (RTHC02) is a rapid lateral flow immunochromatography test for the qualitative detection of antibodies against the hepatitis C virus (anti-HCV) in whole blood, serum or plasma samples (S/S/P format). It is designed for clinical laboratories, gynaecology and obstetrics clinics, primary care, occupational health units, blood banks and serological screening campaigns, and provides a visual result in 15-20 minutes without the need for additional instrumentation.
Supplied in a box of 40 units (ref. V05C-INFO), it allows the cost per test to be optimised in centres with medium and high demand, with the guarantee of a product with CE marking for in vitro diagnostics and easy handling by qualified healthcare personnel, without requiring advanced training or automated readers.
How the anti-HCV antibody test works
The HCV-Test Hep C is a chromatographic lateral flow immunoassay that uses recombinant antigens corresponding to the conserved regions of the HCV genome (Core, NS3, NS4 and NS5). When the sample together with the buffer solution is placed in the device well, the anti-HCV antibodies present migrate by capillary action and react with the conjugates, generating a coloured line in the test (T) zone.
A control line (C) validates in each test the correct migration of the sample and the volume applied: the appearance of two lines indicates a positive result (reactive), while a single line in the control zone confirms a negative result (non-reactive). If the control line does not appear, the result is considered invalid and must be repeated with a new device. Positive or doubtful results must be confirmed with reference laboratory methods (ELISA or immunoblot) before making clinical decisions.
By detecting antibodies against the conserved regions of the virus, the test covers the different HCV genotypes, with a declared performance by the manufacturer of 100 % sensitivity and 100 % specificity.
Technical specifications
| Parameter | Specification |
|---|---|
| Test type | Lateral flow chromatographic immunoassay (cassette format) |
| Manufacturer reference | RTHC02 |
| Reference Cahnos | V05C-INFO |
| Analyte detected | Anti-HCV antibodies (anti-HCV) against conserved regions Core, NS3, NS4 and NS5 |
| Sample type | Whole blood, serum or plasma (S/S/P) |
| Result type | Qualitative, visual reading (test T line and control C line) |
| Time to result | 15-20 minutes |
| Presentation | Box of 40 units (price per box) |
| Sensitivity | 100 % (according to manufacturer’s data) |
| Specificity | 100 % (according to manufacturer’s data) |
| Use | In vitro diagnostics (IVD) by qualified healthcare personnel, single-use |
| Storage | Ambient or refrigerated temperature (2-30 °C); do not freeze; protect from moisture |
| Marking | CE for in vitro diagnostics |
Interpretation of results
| Reading | Interpretation |
|---|---|
| Two lines (T and C) | Positive (reactive): presence of anti-HCV antibodies; confirm with reference method |
| Only control line (C) | Negative (non-reactive) |
| No control line | Invalid: repeat the test with a new device |
Contents per test unit
| Item | Description |
|---|---|
| Test device | Immunochromatography cassette with individual packaging |
| Buffer solution | Assay reagent (well application) |
| Disposable dropper | For sample application |
| Instruction manual | Instructions for use and reading |
Note: the sensitivity and specificity data correspond to the values published by the manufacturer and disseminated by authorised distributors; consult the declaration of conformity and the complete technical documentation on request. The acronym S/S/P stands for the accepted sample matrices (Whole Blood / Serum / Plasma).
Equivalences and cross-references
The reference RTHC02 is the manufacturer code for the anti-HCV test in cassette format for whole blood, serum or plasma, marketed in the Cahnos catalogue as V05C-INFO (box of 40 units). The references from other manufacturers indicated below are functional category comparisons verified against official catalogues, IFUs and regulatory databases of the respective manufacturers; they are not 1:1 interchangeable and must be validated property by property (format, analyte, sample type, reading time and presentation) before any substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Hangzhou Alltest Biotech (JusChek range) | HCV Rapid Test Cassette (Whole Blood/Serum/Plasma) | IHC-402 (also 146250200) | Comparable by category (not interchangeable 1:1) | Same analyte (anti-HCV antibodies) in the same matrices (whole blood, serum, plasma); lateral flow cassette with CE marking; presentation of 40 kits per box with buffer, dropper and manual. Official reference confirmed in the manufacturer’s IFU (REF IHC-402 / 146250200). Available in the Cahnos catalogue as ref. IHC-402. |
| SD Biosensor | STANDARD Q HCV Ab | 09HCV10D | Comparable by category (not interchangeable 1:1) | Immunochromatography for anti-HCV antibodies in serum, plasma or whole blood; rapid reading (around 5-20 minutes depending on kit); prequalified by the WHO (PQDx 0360-117-00); variable presentations depending on presentation. Code confirmed in the WHO prequalification database and in the manufacturer’s official catalogue; confirm the presentation reference. |
| CTK Biotech | OnSite HCV Ab Plus Combo Rapid Test | R0024C | Comparable by category (not interchangeable 1:1) | Double antigen immunoassay for anti-HCV IgG, IgM and IgA antibodies in whole blood, serum or plasma; reading in 15-20 minutes; sensitivity 100 % and specificity 99.9 % according to published data. Code confirmed on the manufacturer’s official website; verify presentation reference. |
| BTNX Inc | Rapid Response™ Hepatitis C Virus (HCV) Test Cassette | HCV-13C40 | Comparable by category (not interchangeable 1:1) | Chromatographic immunoassay for qualitative detection of anti-HCV antibodies in whole blood, serum or plasma; presentation of 40 tests per box; reading in 10 minutes and declared accuracy of 99 %. Code confirmed on the manufacturer’s official website; verify CE marking/MDR of the presentation. |
There is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in a tender. The equivalences indicated are functional category comparisons, not 1:1 interchangeable: before substituting, verify in each technical data sheet the device format, the analyte detected (anti-HCV), the authorised sample type, the reading time, the scope of use (professional) and the performance data against the serological reference method. Within the hepatitis panel, this test is complemented in the catalogue by the hepatitis B tests (HBsAg, ref. V05-INFO / IHBSG-402), Anti-HBs antibodies (ref. V05-1-INFO) and hepatitis E (ref. IHE-302), allowing complete hepatic serological screening from a single supplier.
Selection tips and variants of interest
- S/S/P format: accepts whole blood, serum or plasma, allowing sample collection to be adapted to each workflow (finger prick, serum or plasma tube).
- Care volume: the box of 40 units balances cost per test and storage; for centres with lower demand or occasional demand, consult the individual presentations of the same anti-HCV cassette family (ref. IHC-402).
- Serological panel: for hepatitis screening in gynaecology and obstetrics, combine this anti-HCV test with the determination of HBsAg (hepatitis B) and Anti-HBs, and consider the hepatitis E test if the epidemiological profile advises it.
- Confirmation: positive or equivocal results must be confirmed by reference laboratory techniques (ELISA, immunoblot or PCR) before making clinical decisions.
- Storage: keep the kit between 2-30 °C, protected from heat, humidity and direct sunlight; do not freeze and respect the expiry date printed on each sealed package.
- Professional use: intended for qualified healthcare personnel; do not reuse the device and treat all samples as potentially infectious.





Reviews