Description
Cytological aluminium swab with STUART medium
The cytological aluminium swab with STUART transport medium (ref. 0330507) is the sampling device that your gynaecology practice, microbiology service or clinical laboratory needs to guarantee the integrity of each sample, from collection to analysis. Its aluminium shaft combines rigidity and lightness with controlled flexibility: it can be slightly bent to adapt the access angle without fracturing, facilitating cervical, vaginal, urethral or pharyngeal collection even in hard-to-reach areas. Each unit is supplied in an individual peel-pack with a polypropylene tube containing the transport medium, ready to use, sterile and disposable.
Available in a box of 100 units, it is the continuous stock solution for centres that process a high volume of samples and need a reliable, traceable collection system that complies with European regulations.
What it is and how to use it
The cytological swab is a single-use brush consisting of an applicator shaft and an absorption area at the tip, used to collect cells and microorganisms from mucosal surfaces. After collection, the brush is inserted into the tube with modified STUART medium: a semi-solid, reduced transport medium with thioglycolate, which inhibits autolysis enzymatic reactions and lacks a nitrogen source, preventing the proliferation of accompanying flora. In this way, it preserves a wide spectrum of pathogens —Neisseria gonorrhoeae, Haemophilus influenzae, Neisseria meningitidis, Bordetella pertussis, Corynebacterium diphtheriae, Trichomonas vaginalis, Staphylococcus aureus, Streptococcus sp., Salmonella sp., Shigella sp., among others— during transport to the laboratory. The most labile microorganisms remain viable for approximately 24 hours and other species for several days, allowing subsequent processing for culture, bacteriology or molecular techniques. The procedure is simple: open the sterile peel-pack, take the sample, reinsert the brush into the tube, close the safety cap and label with the patient’s data before sending.
Technical specifications
| Reference | 0330507 |
| Product type | Cytological swab (brush) with transport medium |
| Shaft | Thin and adaptable aluminium, can be bent to create access angles |
| Transport medium | Modified STUART (semi-solid), in polypropylene tube |
| Sample preservation | Labile microorganisms: approx. 24 h; other species: several days, at room temperature |
| Sterility | Sterile by radiation |
| Expiry | 30 months from the date of sterilisation |
| Individual packaging | Peel-pack of 38 x 210 mm |
| CE classification | Swab: CE MDD Class IIa · Tube: CE IVD |
| Use | Single-use · disposable |
| Presentation | Box of 100 units |
| Applications | Cervical and vaginal cytology, urethral and pharyngeal exudates, clinical microbiology |
Note: the stated viability comes from the manufacturer’s technical data sheet; the actual preservation time depends on the microorganism and transport conditions.
Equivalences and cross-references
Below are listed references from other manufacturers that correspond to the same product category (swab or brush with aluminium shaft and STUART transport medium, sterile, in tube). The codes have been cross-checked against official catalogues or technical data sheets of the cited manufacturers.
| Manufacturer / Brand | Reference | Equivalence level | Technical differences / Remarks |
| Deltalab® | 300291 | Comparable by category (not interchangeable 1:1) | Stuart Swab sterile aluminium and cotton, peel-pack 38 x 210 mm, modified STUART medium, expiry 30 months; commercial presentation of 600 units (does not match the 100-unit presentation). |
| Copan® Transystem™ | 142C | Comparable by category (not interchangeable 1:1) | Regular aluminium wire brush with liquid Stuart medium, rayon tip, orange cap; presentation of 50 units. |
| Vacutest Kima® (distributor Securlab) | K230507 | Comparable by category (not interchangeable 1:1) | Cervical/urethral brush with flexible aluminium shaft (149 mm, Ø 0.9 mm) with polypropylene tube and STUART medium, sterile (CE 0373), box of 100 units. Presentation format very similar to ref. 0330507. |
There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders.
Selection tips and variants of interest
Choose the sampling system according to the transport medium required by your laboratory protocol and the type of sample. This swab with STUART medium is the ideal option for the preservation and transport of a broad bacterial spectrum at room temperature; if your laboratory works with Amies-based gelled media or with charcoal, consider the variants with AMIES medium. Within our catalogue you will find complementary alternatives: the plastic cytological swab with STUART medium (ref. 0330111) and with AMNIES medium (ref. 0330108) for protocols that prefer a rigid plastic shaft; the swab in a tube without medium, sterile (ref. 0658019) for direct collection with immediate plating; or the sterile (ref. 0438003) and non-sterile (ref. 0658001) wood and cotton swabs for general examination and topical application uses. Complement sampling with vaginal specula, endocervical brushes and cytological fixatives, available at Cahnos. For institutional orders, the box of 100 units allows efficient stock rotation and dispensing.





Reviews
There are no reviews yet.