Description
1. Introduction
The sterile staple remover forceps with metal tip (ref. 0438119) is the disposable instrument your centre needs to remove skin suture staples quickly, safely and with minimal trauma to the patient. Its scissor-type design, with ergonomic plastic handle and stainless steel mouth, allows clean, jerk-free extraction, reducing procedure discomfort and streamlining the work of healthcare staff in consultations, wound dressings, emergency departments and operating theatres. It is supplied sterile, in an easy-open individual package, ready for immediate use.
It is a single-use solution with excellent value for money for purchasing centres and services that need a constant supply of mechanical suture removal instruments.
2. Technical explanation and instructions for use
The staple remover forceps consists of two asymmetric plastic arms and a tip of anti-corrosive stainless steel, itself composed of two pieces: one in the form of a rounded atraumatic tongue, which is safely inserted under the staple pressing on the skin, and another in the form of a parrot beak, which, when the arms are fully squeezed, catches and bends the staple in half; the staple ends then come out of the skin in an M shape, minimising the pain of the procedure.
Instructions for use in three steps:
- Insert the front part of the forceps under the suture staple and slide the staple into the notch of the lower jaw.
- Squeeze the forceps handle until the upper and lower faces are in place.
- Confirm that the staple has deformed and separated from the skin, and remove it gently.
It is suitable for removing the staples from both skin staplers (medium and large staples) and is free from latex and phthalates. The product is sterilised by ethylene oxide (EO) and is supplied in an easy-open sterile individual package.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference (SKU Cahnos) | 0438119 |
| Manufacturer reference | WZDSS-P1-35W (according to the product technical documentation) |
| Product type | Disposable staple remover forceps, scissor type |
| Handle material | Plastic, two asymmetric arms, ergonomic handle |
| Tip material | Anti-corrosive stainless steel |
| Tip design | Atraumatic rounded tongue + parrot-beak piece |
| Extraction mechanism | Bends the staple in half and removes it in an M shape |
| Sterility | Sterile by ethylene oxide (EO), individual package |
| Composition | Latex-free and phthalate-free |
| Use | Single-use (disposable, not re-sterilisable) |
| Application | Removal of skin suture staples from medium and large skin staplers |
| Presentation | Easy-open individual package; unit on mixed |
| Units per box | Box of 150 units |
| EAN code (unit) | (01)06971222391174 |
| Regulation | Medical device with CE marking |
4. Equivalences and Cross-References
Reference 0438119 corresponds to the distributor’s nomenclature (Cahnos) for the product identified in its technical data sheet with the manufacturer’s reference WZDSS-P1-35W. There is no equivalence table validated by the manufacturer that cross-references this reference with those of other brands; the following alternatives are offered as a functional category comparison verified against official sources from each manufacturer and, unless otherwise indicated, are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| B. Braun (Aesculap) | Single-Use Skin Staple Remover (disposable staple remover) | 783101 (EAN 4045439030712) | Comparable by category (not interchangeable 1:1) | Same concept: plastic handle with metal tip, sterile and single-use; it is marketed in a pack of 6 units and sterilised by gamma radiation. Verified in the official catalogue of B. Braun and authorised distributor. |
| Hartmann | MediSet Staple Remover | 706146 INT | Comparable by category (not interchangeable 1:1) | Sterile single-use staple remover, fully metallic (stainless steel, 10 cm) with a tray for collecting staples; compared to the plastic handle and metal tip design of our forceps. Verified on Hartmann’s official website. |
| SMI | Plastic Staple Remover (plastic staple remover) | ZSR2 | Comparable by category (not interchangeable 1:1) | Disposable plastic staple remover, sterile and individually packaged; usual presentation of 50 units. Same clinical function; verify performance and traceability. Verified at authorised distributor. |
| Catalogue Cahnos | Disposable Staple Remover (KHPF series) | KHPF-CA / KHPF-CB | Comparable by category (not interchangeable 1:1) | Staple remover recommended for its skin staplers (KHPF-CA applicable to types W and B; KHPF-CB to type B); factory-sterilised although described as reusable after disinfection, compared to the single-use of our forceps. Verified on the manufacturer’s official website. |
There is no equivalence table validated by the manufacturer that cross-references this reference with those of other brands; consult the technical department before using in tenders.
5. Selection tips and variants of interest
- Pre-use verification: check the integrity of the sterile individual package and the indicated expiry date; if the package is punctured or damaged, discard the unit.
- Single-use: the forceps are disposable and must not be re-sterilised or reused; dispose of after the procedure in accordance with the centre’s healthcare waste regulations.
- Compatibility: suitable for removing staples from medium and large skin staplers; for KHPF series staplers from the Cahnos catalogue, the complementary references KHPF-CW and KHPF-CB cover the same removal function.
- Purchase optimisation: the box presentation of 150 units allows stock to be standardised and reduces the unit cost in B2B volumes; the single unit is also supplied on mixed orders.
- Intended use environment: although it is classified within disposable gynaecology instruments, its application is universal in any department that performs removal of mechanical sutures: wound dressings, emergency departments, minor ambulatory surgery, hospitalisation wards and the operating theatre.
- For queries about equivalence, approval in tender specifications or special conditions by volume, contact our technical-commercial department.