We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Citovac 4 – Sterile Cornier cannula kit for endometrial sampling by suction, with graduated 5 ml syringe, transport tube and label (Ref. 0438023) · Sterile individual package · Sold per unit

3,14 €

Citovac 4 (Ref. 0438023) is the reference sterile Cornier cannula kit for endometrial sampling by suction in gynaecology practice. Each individual package includes a Cornier-type suction cannula with 1 orifice (Ø 2.9 mm × 20 cm, female luer connection), graduated 5 ml syringe, transport tube with cap and patient identification label. Single-use device sterilised by ethylene oxide, allows quick, comfortable and reliable sampling without the need for cervical dilation. Price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0438023

Description

1. Introduction

The Citovac 4 kit (Ref. 0438023) is the complete solution for endometrial sample collection by suction in the gynaecology clinic. Supplied in sterile individual packaging, it includes everything needed to perform the collection in a single procedure: Cornier-type suction cannula, 5 ml graduated syringe, transport tube with cap and patient identification label. A practical, safe, single-use device designed for outpatient endometrial diagnosis with maximum patient comfort and full autonomy for the professional.

2. Technical explanation of the procedure

Endometrial suction is a minimally invasive diagnostic technique that allows obtaining a sample of the uterine mucosa for cytological and histological study, without prior cervical dilation. In the Citovac 4 kit, the Cornier cannula (with one suction orifice and female Luer connection) is introduced through the cervical canal into the uterine cavity; the 5 ml graduated syringe is then attached via its Luer-Lock connection and, by retracting the plunger, negative pressure is generated that adheres the endometrial tissue to the cannula wall. Gently rotating the device between the fingers while moving it through the cavity achieves optimal contact with the uterine wall and a representative sample in seconds. The sample is then placed in the transport tube with cap included and identified with the patient label before being sent to the laboratory.

3. Technical Specifications

Reference 0438023
Product type Sterile Cornier cannula kit for endometrial suction
Contents Cannula, 5 ml graduated syringe, transport tube with cap and patient identification label
Cannula measurements Length 20 cm · outer diameter 2.9 mm
Tip configuration One suction orifice
Connection Female Luer (for syringe with Luer-Lock connection)
Suction system 5 ml graduated syringe
Material Medical-grade plastic (thermoplastic polymer)
Sterilisation Ethylene oxide (EO) · sterile individual packaging
Use Single-use (disposable)
Presentation Sterile individual packaging · sold per unit
Intended use Endometrial sample collection by suction (cytological and histological study)
Classification Medical device with CE marking

Kit contents:

Component Description
Suction cannula Cornier type, 1 orifice, female Luer connection, graduated (reference guide, no measurement function)
Syringe 5 ml graduated, Luer-Lock connection
Transport tube With cap, for safe sample transport
Label Patient identification

4. Equivalences and Cross-References

There is no cross-reference table validated by the manufacturer for this kit. The alternatives listed below belong to the same clinical category — sterile single-use endometrial suction devices — and may be used as guidance in purchasing and approval processes, subject to technical verification. It should be noted that the Citovac 4 is a complete kit (cannula + syringe + tube + label), while most of the compared products are marketed as individual cannulae, so none is interchangeable 1:1.

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
CooperSurgical Pipelle – Endometrial Suction Curette (Ø 3.1 mm) 8200 Comparable by category (not interchangeable 1:1) Self-contained cannula with internal vacuum piston, Ø 3.1 mm, sterile, single-use, box of 25 units; does not include syringe or transport tube. Verified in the manufacturer’s official catalogue and in GUDID (DI 00888937003475).
Laboratoires CCD Pipelle de Cornier 3.1 mm 1103000 Comparable by category (not interchangeable 1:1) Flexible polypropylene cannula, outer Ø 3.1 mm × 23.5 cm, with lateral orifice; does not include syringe or tube. Verified in GUDID (DI 03700111400719).
MedGyn Pipette 3.1 mm (Endometrial Pipette) 022721 Comparable by category (not interchangeable 1:1) Semirigid disposable cannula Ø 3.1 mm, sterile, single-use, box of 25 units; verified in GUDID (DI M803022721). Does not include syringe, transport tube or label.
MedGyn Pipette IV multi-orifice 3.1 mm 022730 Comparable by category (not interchangeable 1:1) Four-orifice design, Ø 3.1 mm, sterile, single-use, box of 25 units; verified in GUDID (DI M803022730). Does not include syringe, transport tube or label.
GIMA Sterile Pipella with 1 orifice 29826 Comparable by category (not interchangeable 1:1) Sterile single-use gynaecological collector, outer Ø 3.1 mm and cannula 23.5 cm; usually supplied in a box of 100 units. Verified in the manufacturer’s official manual (EAN 8023279298260). Does not include syringe, transport tube or label.

There is no equivalence table validated by the manufacturer; consult the technical department before using in tenders. The references cited have been verified in public sources (official manufacturer website and GUDID database) or in official manuals as support; as these are individual cannulas without syringe or transport tube, none is interchangeable 1:1 with this kit without prior verification of dimensions, material and marking of the specific batch.

5. Selection tips and variants of interest

  • Complete kit vs. individual cannula: the Citovac 4 (Ref. 0438023) includes cannula, syringe, tube and label in a single package, ideal for practices with workload and sample traceability. If you prefer to purchase only cannulas, Cahnos offers the Cornier endometrial suction cannula with one orifice (Ref. 720196) and with two orifices (Ref. 0438107), in a box of 25 units.
  • Sampling technique: previously check the uterine depth with a disposable hysterometer (Ref. 0438019) and withdraw the syringe gently to avoid excessive vacuum on the mucosa.
  • Sample handling: after sampling, place the tissue in the transport tube with cap, identify with the patient label and send to the laboratory; dispose of the device after use.
  • Other endometrial sampling options: for scraping biopsy, Cahnos offers the sterile Endoram (Ref. 720112); for sampling with steel mandrel, the Endocic (Ref. 720195).
  • Storage: keep the package intact in a cool, dry place; use only if the sterile seal is intact and within the expiry date.
  • Volume purchases: for full box requirements (100 units) or tender processes, consult our commercial team for special conditions.

Additional information

Product type

Sterile Cornier cannula kit for endometrial suction

Contents

Suction cannula (1 orifice), 5 ml graduated syringe, transport tube with cap and patient identification label

Cannula measurements

Length 20 cm · outer diameter 2.9 mm

Tip configuration

One suction orifice

Suction system

5 ml graduated syringe

Material

Medical-grade plastic (thermoplastic polymer)

Sterilisation

Ethylene oxide (EO) · sterile individual packaging

Use

Single-use (disposable)

Presentation

Sterile individual packaging · sold per unit

Intended use

Endometrial sample collection by suction (cytological and histological study)

Classification

Medical device with CE marking

Reference

0438023

Connection

Female Luer (for syringe with Luer-Lock connection)

Reviews

There are no reviews yet.

Be the first to review “Citovac 4 – Sterile Cornier cannula kit for endometrial sampling by suction, with graduated 5 ml syringe, transport tube and label (Ref. 0438023) · Sterile individual package · Sold per unit”

Your email address will not be published. Required fields are marked *