Sterile atraumatic bevelled latex tracheal suction tube for tracheostomy – 6 diameters (2.6–6 mm)

Price on request

Bevelled atraumatic tracheal suction tube in sterile latex, single-use, for draining secretions from the airways in patients with a tracheostomy cannula or endotracheal tube. Its bevelled distal end allows smooth and atraumatic progression through the cannula, minimising the risk of mucosal injury; the proximal end incorporates a conical cup with vacuum stop that ensures a sealed connection with syringe, surgical suction unit or vacuum system. Available in 6 diameters from 2.6 to 6 mm (sizes 8 to 18 French/channels), with an approximate length of 40 cm. Reference A06S.

International shipping. Import duties and taxes are payable by the recipient.

Reference
A06S

Description

1. Introduction

The bevelled atraumatic tracheal suction tube (ref. A06S) is a sterile single-use latex catheter, designed to keep the airways of tracheostomised or intubated patients who cannot expectorate on their own clear and patent. It is the reference technical solution in intensive care units, resuscitation, pulmonology and endoscopy services where effective, safe and reproducible tracheal suction is required, with a hospital consumption of high-turnover consumable material.

2. Technical explanation of the device

The catheter is introduced through the already placed tracheostomy cannula or endotracheal tube and is connected at its proximal end to a vacuum-generating system (surgical suction unit, wall outlet or syringe orifice). The bevelled distal end favours atraumatic advancement through the lumen of the cannula, reducing traumatic contact with the tracheal mucosa and the risk of injury during the manoeuvre. The proximal end with conical cup acts as a vacuum stop, ensuring a sealed connection of the system that prevents pressure leaks and optimises suction efficiency. Suction of tracheal and bronchial secretions is an essential life-support technique in patients with an artificial airway: it removes mucus, blood and secretions accumulated over the cannula balloon, prevents tube obstructions and reduces the risk of pneumonia associated with aspiration of contaminated content.

3. Technical Specifications

Sterile single-use latex catheter, with atraumatic bevelled distal end and proximal end with conical cup (vacuum stop). Approximate length 40 cm. It is marketed in 6 diameters, each identified by its diameter in millimetres and its gauge in French (channels):

Diameter (mm) French gauge (channels) Indicative use
2.6 mm 8 Paediatric / small cannulas
3.3 mm 10 Paediatric
4.0 mm 12 Paediatric / small adult
4.6 mm 14 Adult
5.3 mm 16 Adult
6.0 mm 18 Adult / large-gauge cannulas

Selection rule: the diameter of the suction catheter must be, at most, equal to half the internal diameter of the tracheal cannula, to allow air passage during the manoeuvre and avoid collapse of respiratory flow.

4. Equivalences and Cross-References

This tube belongs to the family of single-use latex tracheal suction catheters, with a bevelled profile and proximal vacuum connection. Its function is comparable to single-use tracheal suction catheters from manufacturers such as Vygon (tracheal suction catheters for nasal, oral or through tracheotomy cannula), Flexicare (sterile suction catheters with rounded tip and vacuum control), BOENMED (latex suction catheters to keep the airway clear) and Mevesur (disposable suction catheters). Unlike PVC catheters with lateral vacuum control, the latex model with conical cup is oriented towards a sealed connection with conventional suction units and use in long-stay tracheostomised patients. For endotracheal tubes with integrated suction lumen, Cahnos has references ETSL60C02 to ETSL90C02.

5. Selection tips and variants of interest

Select the size according to the internal diameter of the patient’s cannula or tube, always applying the rule of half the internal diameter; for adults, sizes 14–18 French are usually used and for paediatrics sizes 8–12 French. Perform short, intermittent suctions, with moderate vacuum pressure, and using sterile technique (gloves and single-use catheter) to avoid cross-contamination. If the patient has very viscous secretions, consider combining suction with prescribed lavage and humidification solutions. In endoscopy and gastroenterology settings, this catheter is also of interest as an accessory suction element in procedures that require clearing the patient’s airway during the examination. Check availability of boxes and ordering conditions per unit by requesting a quote at Cahnos.

Additional information

Material

Natural latex, sterile

Presentation

Sterile single-use unit

Length

Approx. 40 cm

Available diameters

2.6 / 3.3 / 4 / 4.6 / 5.3 / 6 mm (sizes 8 to 18 French)

Distal end

Atraumatic bevel

Proximal end

Conical cup with vacuum stop (sealed connection)

Compatibility

Syringes, surgical suction units and vacuum systems with stop; tracheostomy cannulas and endotracheal tubes

Selection rule

Catheter diameter equal to or less than half the internal diameter of the cannula

Intended use

Tracheal suction of secretions in tracheostomised or intubated patients

Sterilisation

Sterilised, ready to use (single-use)