We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Graduated 5-channel anorectal manometry catheter – Perfusion catheter for anal motility recording (distension balloon 200 ml, L 120 cm, Ø 6.6 mm / 20 CV) | C66U

Price on request

Graduated 5-channel anorectal manometry catheter (ref. C66U) for reliable recording of anal motility by perfusion of sterile water. It incorporates four perfusion ports located at 1.5, 5, 6 and 7 cm from the distal end and a 200 ml distension balloon that allows controlled studies of pelvic floor function. With a calibre of 6.6 mm (20 CV) and a length of 120 cm, it is the reference tool for gastroenterology departments, digestive physiology units, motility laboratories and urodynamics clinics seeking precise and reproducible measurements.

International shipping. Import duties and taxes are payable by the recipient.

Reference
C66U
Tags

Description

1. Introduction

The graduated 5-channel anorectal manometry catheter (ref. C66U) is the technical solution that your gastroenterology department, digestive physiology unit or motility laboratory needs to accurately record anal motility and assess pelvic floor disorders. Its graduated design, multichannel configuration and 200 ml distension balloon allow complete manometric studies to be performed with stable, reproducible and clinically reliable pressure curves. A professional reference choice for functional anorectal diagnostics in adult patients.

2. Technical explanation of the equipment and procedure

During anorectal manometry, the catheter is inserted rectally and, once positioned, the four perfusion ports are connected to the transducers of the recording system. Each port is perfused with sterile water at a constant flow rate, allowing pressure curves to be obtained at specific points of the anorectal canal: the positions closest to the distal end record the pressure of the proximal rectal region, while the ports located further away assess the pressure in the anal sphincter area. The distension balloon, with a maximum capacity of 200 ml, is inflated in a controlled manner to study the response of the rectal wall and the reflexes related to defecation. The independent lumens prevent interference between the inflation and measurement channels, ensuring clinically reliable signals throughout the examination. The graduated scale allows the position and depth of insertion to be controlled in each test.

3. Technical Specifications

The main features of the C66U catheter are summarised in the following table:

Characteristic Specification
Configuration 5 channels (4 perfusion ports for pressure recording + distension balloon channel)
Perfusion ports 4 separate ports for pressure recording at specific distances
Port distances 1.5 cm, 5 cm, 6 cm and 7 cm from the distal end
Distension balloon Maximum injected volume of 200 ml for controlled distension
Gauge 6.6 mm (20 CV)
Total length 120 cm
Measurement system Constant-flow sterile water perfusion
Graduation Graduated scale for controlling insertion position and depth
Indication Anorectal manometry, anal motility recording and diagnostics of pelvic floor disorders

Functional distribution of ports and channels:

Channel / Port Function
Ports at 1.5 cm and 5 cm from the distal end Pressure recording in the proximal rectal region
Ports at 6 cm and 7 cm from the distal end Pressure recording in the anal sphincter area
Balloon channel Inflation of the distension balloon (max. 200 ml) for controlled distension studies

4. Equivalences and Cross-References

The C66U meets the standard of multichannel perfusion catheter with balloon for anorectal manometry used by the main manufacturers of digestive motility equipment. It has functional correspondence with the water-perfused balloon-type catheters from companies such as Laborie and Albyn Medical in 5-channel configurations for simultaneous recording of rectal pressure, sphincter pressure and distension, as well as with the perfused anorectal measurement catheters of the urodynamics series from the Rüsch / Teleflex group (colour-coded accessory connection, sterile and latex-free). Within the Cahnos catalogue, its closest equivalent is the graduated manometry and compliance catheter C56U, which adds radiopaque markers and rectal distensibility study, and the non-graduated version C74U of the same 5-channel configuration. For exclusive compliance studies, it is complemented with the bidirectional compliance rectal tube C55U.

5. Selection tips and variants of interest

Select the C66U when your protocol requires a graduated 5-channel catheter with a 200 ml distension balloon for standard recording of anal motility and sphincter pressure. If you also need to measure rectal distensibility with radiographic localisation of the measurement points, consider the graduated C56U catheter; if you do not need graduation or radiographic reference, the C74U offers the same functional configuration. For higher resolution in adult patients, the 7-channel C91AU catheter and the 4-channel Arhan C54U model are available; for the paediatric population, the graduated C69U catheter with a 100 ml balloon. For bubble-free filling of the balloons, complement the equipment with the C57U filling needle. Always verify the compatibility of connectors and transducers with your manometry system; at Cahnos we supply on request and with a formalised quotation under special conditions for B2B professionals.

Additional information

Reference

C66U

Configuration

5 channels (4 perfusion ports + distension balloon channel)

Perfusion ports

4

Port distances

1.5 cm, 5 cm, 6 cm and 7 cm from the distal end

Distension balloon

200 ml maximum injected volume

Gauge

6.6 mm (20 CV)

Measurement system

Constant-flow sterile water perfusion

Graduations

Graduated scale for position and depth control

Indications

Anorectal manometry, anal motility and diagnostics of pelvic floor disorders

Numero vias

5

Longitud

120 cm

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Graduated 5-channel anorectal manometry catheter – Perfusion catheter for anal motility recording (distension balloon 200 ml, L 120 cm, Ø 6.6 mm / 20 CV) | C66U”

Your email address will not be published. Required fields are marked *