Description
C624 radiopaque markers for the study of colonic transit
The radiopaque markers of reference C624 allow your gastroenterology department or digestive physiology unit to objectively measure colonic transit time (CTT) without relying on patient history, which is not always reliable. A safe, non-invasive method that is easy to apply in outpatient clinics and hospitals, indicated for the assessment of chronic constipation, intestinal motility disorders, monitoring of digestive therapies, and clinical research in functional gastroenterology.
How the method works
The technique is based on radiographic tracking of the migration of orally ingested radiopaque markers along the colon. The patient ingests one capsule every 24 hours, always at the same time, for 6 consecutive days. On the seventh day (D+7), a single plain abdominal X-ray is taken in the anteroposterior projection without preparation (AXR). By dividing the abdomen into three areas of interest (right colon, left colon and rectosigmoid), the clinician counts the markers present in each segment and obtains the transit time using the formula T = 2.4 × n, where n is the number of markers counted in the segment. The cubic shape of the markers facilitates their identification and quantification on the X-ray, allowing differentiation between segmental and total transit.
Technical specifications
| Characteristic | Specification |
|---|---|
| Family and manufacturer | Transi-Mark® – Marquat Genie Biomedical (France) |
| Marker shape | Cubic (2.5 mm) in C624C and C624-C6; round in C624R |
| Marker material | Medical-grade silicone impregnated with barium sulphate (43%) |
| Capsule material | Vegetable hypromellose (oral dissolution) |
| Markers per capsule | 10 |
| Pack sizes | Blister of 6 capsules (C624-C6 Transi-Mark®); sachets of 100 capsules (C624C / C624R) |
| Ingestion protocol | 1 capsule every 24 hours at a fixed time for 6 days |
| Diagnostic modality | Plain abdominal X-ray (AXR), anteroposterior projection, on day 7 |
| Transit calculation | T = 2.4 × n (n = markers counted in the segment) |
| Certification | In vitro diagnostic medical device with CE marking |
| Instructions | In 6 languages, with a tracking calendar on the packaging |
Indicative normal thresholds (European population, hours)
| Colonic segment | Male (hours) | Female (hours) |
|---|---|---|
| Right colon | 19 | 22 |
| Left colon | 16 | 48 |
| Rectosigmoid | 21 | 38 |
| Total transit | 77 | 91 |
Equivalences and cross-references
Reference C624 belongs to the family of ingestible radiopaque marker systems for measuring colonic transit. Within the same manufacturer range, the references that may be of interest are C624-C6 (kit of 6 capsules, standard format for one patient), C624C (cubic marker in sachets of 100 capsules, for high-volume centres) and C624R (round marker in sachets of 100 capsules).
On the market there are methodologically comparable systems, such as SITZMARKS® markers (ingestible capsules with radiopaque rings for serial colonic transit studies, indicated for chronic constipation, colonic inertia and hypomotility), which are classified as comparable at category level and not interchangeable 1:1, as they differ in the number of markers per capsule, their geometry and the manufacturer.
There is no equivalence table validated by the manufacturer that allows cross-referencing this reference with specific codes from other suppliers; it is recommended to consult the technical department of Cahnos before using this sheet in a tendering process or stock replacement.
Selection tips and variants of interest
- Outpatient diagnostic use: the C624-C6 format (Transi-Mark®) includes exactly the 6 capsules needed to complete the standard protocol in a single patient.
- High-volume centres: the sachets of 100 capsules (C624C or C624R) ensure continuous supply for digestive motility services.
- Marker shape: the cubic markers (C624C and C624-C6) facilitate visual quantification on the X-ray; the round variant (C624R) can be used when it is necessary to differentiate marker series.
- Alternative protocols: for more detailed studies, multiple ingestions and serial X-rays can be combined, a methodology widely documented in the literature on colonic transit.
- Storage: keep in a cool, dry place, in its original packaging and at room temperature.