Description
1. Introduction
We offer you the PREMIUM electrode handles with integrated cable (HF-pencil) from REGER Medizintechnik GmbH (Germany), the reusable handle onto which the active electrodes of your high-frequency (HF) surgery system are attached. The cable already integrated into the handle eliminates intermediate connections, simplifies assembly in the operating theatre and ensures stable current transmission to the electrode. Its reusable and autoclavable design withstands up to 300 sterilisation cycles, reducing the cost per procedure compared with disposable pencils. They are the ideal choice for operating theatres, ambulatory major surgery, minor surgery practices, gynaecology and dermatology.
2. Technical explanation
In monopolar electrosurgery, the electrosurgical generator (ESU) sends high-frequency current through the electrode handle to the active electrode, which concentrates the current density at the tip to cut, coagulate or combine both effects; the circuit is closed by the dispersive neutral plate. This PREMIUM handle secures the electrode via the housing for shafts of Ø 4 and 2.4 mm and distributes the energy through the integrated cable, with direct connection of the specific connector to each generator (Erbe, Storz, Erbe T-Serie, Martin, Berchtold, Integra or Valleylab depending on the chosen reference).
The hexagonal anti-twist protection (hexagon anti-twist protection) of the Ø 4 and 2.4 mm shafts prevents accidental rotation of the tip during the surgical procedure, ensuring a stable and safe orientation of the electrode at all times. Being guaranteed for up to 300 sterilisation cycles, these handles offer a very long service life with consistent cutting and coagulation performance in each cycle.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | REGER Medizintechnik GmbH (Germany) |
| Product type | Electrode handle (HF-pencil) PREMIUM with integrated cable |
| System | High-frequency (HF) monopolar electrosurgery |
| Compatible shaft diameter | 4 mm and 2.4 mm |
| Fixation system | Hexagonal anti-twist protection (shafts Ø 4 and 2.4 mm) |
| Integrated cable length | 3 m and 5 m (depending on reference) |
| Re-sterilisation | Up to 300 cycles |
| Maximum voltage (Umax) | 4.3 kVp |
| Units per pack | 1 |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Length | Connection to the generator | Shaft | Units per pack | Compatible with |
|---|---|---|---|---|---|
| 92247 | 5 m | Erbe, Storz | 4 mm | 1 | Erbe, Storz |
| 92240 | 5 m | Erbe T-Serie | 4 mm | 1 | Erbe T-Serie |
| 92241 | 3 m | Martin, Berchtold, Integra | 4 mm | 1 | Martin, Berchtold, Integra |
| 92243 | 5 m | Martin, Berchtold, Integra | 4 mm | 1 | Martin, Berchtold, Integra |
| 92246 | 3 m | Valleylab, Int. Models 3 Pin | 4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92245 | 5 m | Valleylab, Int. Models 3 Pin | 4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92251 | 5 m | Erbe, Storz | 2.4 mm | 1 | Erbe, Storz |
| 92248 | 5 m | Martin, Berchtold, Integra | 2.4 mm | 1 | Martin, Berchtold, Integra |
| 92242 | 3 m | Valleylab, Int. Models 3 Pin | 2.4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92244 | 5 m | Valleylab, Int. Models 3 Pin | 2.4 mm | 1 | Valleylab, Int. Models 3 Pin |
4. Equivalences and Cross-References
References 92247, 92240, 92241, 92243, 92246, 92245, 92251, 92248, 92242 and 92244 are the original catalogue designations from REGER Medizintechnik for the PREMIUM electrode handles with integrated cable; at Cahnos they are marketed under the RGR-MANGO-PREMIUM-INTEGRADO family (base SKU) with the RGR- prefix per reference.
There is no 1:1 equivalence table validated by the manufacturer with handles from other brands. Reusable electrode handles from other manufacturers (with a 4 or 2.38 mm / 3/32″ shaft) may be comparable by category, but must be validated field by field (shaft diameter, generator connector and fixation system) before any substitution. Within the same HF electrosurgery system from REGER, the cable family for PREMIUM electrode handles (refs. 92070, 92071, 92041, 92040 and 92072), the PREMIUM electrode handles with detachable cable and the electrode handles without buttons (base SKU RGR-MANGO-SIN-BOTONES) are available.
5. Selection tips and variants of interest
Select the reference according to the shaft diameter of your electrodes (4 mm or 2.4 mm) and the connection of your generator:
- For Ø 4 mm shaft: refs. 92247 (Erbe, Storz; 5 m), 92240 (Erbe T-Serie; 5 m), 92241 (Martin, Berchtold, Integra; 3 m), 92243 (Martin, Berchtold, Integra; 5 m), 92246 (Valleylab 3 Pin; 3 m) and 92245 (Valleylab 3 Pin; 5 m).
- For Ø 2.4 mm shaft: refs. 92251 (Erbe, Storz; 5 m), 92248 (Martin, Berchtold, Integra; 5 m), 92242 (Valleylab 3 Pin; 3 m) and 92244 (Valleylab 3 Pin; 5 m).
Choose the 5 m length if the generator is far from the operating table, or the 3 m length for more contained cable management. After each use, subject the handle to sterilisation following the recommended cycle (up to 300 re-sterilisations) and periodically inspect the integrated cable and connection points. For B2B conditions, tenders or volume configurations, consult your technical-commercial advisor at Cahnos.