We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable and sterile electrosurgery pencil with footswitch control, 3.2 mm unipolar PLUG connector, 320 cm cable and removable F4052 needle electrode — FIAB · Ref. F4390/AL (box of 50 units)

Price on request

Monopolar electrosurgery pencil, disposable and sterile, with footswitch control for high-frequency electrosurgery systems. It features a universal unipolar 3.2 mm PLUG connector and 320 cm cable, and is supplied with a removable F4052 needle electrode, ready for precision cutting and coagulation. Footswitch activation frees the surgeon’s hands during the procedure. Manufactured by FIAB (Italy), it comes in a box of 50 individual units, the ideal format for operating theatres, outpatient major surgery and minor surgery with continuous consumption. Official reference F4390/AL.

International shipping. Import duties and taxes are payable by the recipient.

Reference
FIAB-F4390-AL
Brand
FIAB

Description

1. Product Presentation

We offer you the disposable electrosurgery pencil with footswitch control Ref. F4390/AL from FIAB, a renowned European manufacturer of electrosurgery equipment. This is a single-use, sterile, ready-to-use monopolar handpiece designed for those who prefer to activate cutting and coagulation via the generator footswitch, freeing the surgeon’s hands throughout the procedure.

Each unit is supplied with its F4052 removable needle electrode fitted and comes in a box of 50 units with individual packaging: a hygienic solution that eliminates cleaning and re-sterilisation costs and guarantees maximum traceability in the operating theatre, in outpatient major surgery suites and in minor surgery clinics.

2. Technical explanation of the equipment and procedure

In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode — in this case the F4052 needle — which concentrates the energy at the point of contact with the tissue; the circuit is completed through the neutral (dispersive) plate placed on the patient. Depending on the waveform selected from the footswitch, the effect is cutting, coagulation or blended.

This pencil features the universal unipolar 3.2 mm PLUG connection, one of the most widespread connection standards in electrosurgery, and a 320 cm cable that provides a wide working radius over the surgical field. The F4052 needle electrode is removable, allowing quick tip replacement and maintaining a fine contact point, ideal for precision dissection and clean incisions with minimal lateral thermal damage. Being a sterile single-use product, the risk of cross-contamination between patients is eliminated.

3. Technical Specifications

Available references

Characteristic Value
Reference FIAB F4390/AL
Packaging Box of 50 individual units
Units per box (web) 50

Product technical data

Characteristic Specification
SKU Cahnos FIAB-F4390-AL
Manufacturer FIAB SpA (Vicchio, Florence — Italy)
Product type Disposable single-channel electrosurgery pencil (handle) with footswitch control
System High-frequency monopolar
Activation Footswitch control (cut / coagulation)
Connector Universal unipolar, 3.2 mm PLUG type
Cable length 320 cm
Included electrode F4052 needle electrode, removable
Use Single-use (disposable)
Sterility Sterile, individual packaging
Presentation Box of 50 units

4. Equivalences and Cross-References

The reference F4390/AL corresponds to the official catalogue of the manufacturer FIAB, which describes it as a sterile disposable electrosurgery pencil with footswitch control, universal unipolar 3.2 mm PLUG connection, 320 cm cable and removable F4052 electrode (needle), in a box of 50 pieces; Cahnos markets it without altering characters under the SKU FIAB-F4390-AL. No equivalence table validated by the manufacturer has been found that cross-references this part with 1:1 codes from other brands; any substitution must be verified field by field (connector type, cable length, sterility and presentation) with the technical data sheet of the actual product.

Within the FIAB family itself, the reusable pencil with footswitch control and 4 mm plug connector (Ref. F4814, with F4060/4 electrode) constitutes the comparable alternative from the reusable range, and the reusable adapters F4835, F4836, F4837 and F4838 allow adaptation of pencils with 3.2 mm connector to different generator sockets (8 mm, 4 mm, Martin type, Siemens, Erbe, etc.). As replacement electrodes from the FIAB needle family, references F4048 and F4052 are cited (both with universal shaft), always checking compatibility with the pencil holder.

5. Selection tips and variants of interest

Choose footswitch activation if your generator has a footswitch output and you prefer to keep your hands free during dissection and coagulation; if your equipment only features manual switching, consider the disposable pencils with pushbuttons from the same FIAB range. Always confirm the connection standard of your electrosurgical unit: the 3.2 mm unipolar PLUG connector of this pencil adapts to most generators using the reusable FIAB adapters from the F4830–F4838 series when the equipment socket requires it.

The F4052 needle electrode is indicated for fine dissection, precision incisions and spot coagulation in minor surgery, dermatology and general surgery. As a sterile single-use product, it must not be re-sterilised or reused; the box of 50 units facilitates stock management and consumption control in hospitals, clinics and outpatient surgery centres. For B2B volume conditions, hospital supply agreements or validation of equivalents, contact our technical-commercial team.

Additional information

Brand

FIAB

Packaging

box of 50 single units

Manufacturer reference

F4390/AL (FIAB SpA, Italy)

Product type

Disposable monopolar electrosurgery pencil with footswitch control

System

High-frequency monopolar

Activation

Footswitch control (cut / coagulation)

Connector

Universal unipolar, 3.2 mm PLUG type

Cable length

320 cm

Included electrode

F4052 needle electrode, removable

Type of use

Single-use (disposable)

Sterility

Sterile, individual packaging

Presentation

Box of 50 individual units

Units per box

50

Compatibility

Electrosurgical generators with 3.2 mm unipolar PLUG connector (FIAB F4830-F4838 adapters for other sockets)

Manufacturer

FIAB SpA (Vicchio, Florence — Italy)

Documentation

Reviews

There are no reviews yet.

Be the first to review “Disposable and sterile electrosurgery pencil with footswitch control, 3.2 mm unipolar PLUG connector, 320 cm cable and removable F4052 needle electrode — FIAB · Ref. F4390/AL (box of 50 units)”

Your email address will not be published. Required fields are marked *